ASTM D4921-1995(2006) Standard Test Method for Foaming Tendencies of Engine Coolants at Room Temperature《室温下发动机冷却剂发泡倾向的标准试验方法》.pdf
《ASTM D4921-1995(2006) Standard Test Method for Foaming Tendencies of Engine Coolants at Room Temperature《室温下发动机冷却剂发泡倾向的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4921-1995(2006) Standard Test Method for Foaming Tendencies of Engine Coolants at Room Temperature《室温下发动机冷却剂发泡倾向的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4921 95 (Reapproved 2006)Standard Test Method forFoaming Tendencies of Engine Coolants at RoomTemperature1This standard is issued under the fixed designation D 4921; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method applies to a simple shake test forevaluating the tendency of an aqueous solution of engine
3、coolant to foam at room temperature.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limi
4、tations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1176 Practice for Sampling and Preparing Aqueous So-lutions of Engine Coolants or Antirusts for Testing Pur-poses3. Summary of Test Method3.1 A 30 % by volume coolant concentrate solution isprepared in deionized water and shaken in a
5、stoppered gradu-ated cylinder for 30 s. The volume of foam formed in thecylinder is read in millilitres. Preparation of the sample is donein accordance with Test Method D 1176.4. Significance and Use4.1 The test method will generally identify coolants thathave a tendency to foam excessively at room
6、temperature.NOTE 1In use, the foaming tendency of a coolant solution may beincreased by service aging or contamination.5. Apparatus5.1 Graduated Cylinders100-mL graduated cylinderswith plastic stoppers are preferred for ease of handling.35.2 Water BathA water bath or equivalent device capableof main
7、taining temperature at 20 6 1C.6. Reagents6.1 Deionized Water.7. Test Conditions7.1 Test Temperature The test solution shall be main-tained at 20 6 1C for 30 min before shaking.7.2 Shake RateThe graduated cylinder containing the testsolution should be shaken vigorously for 30 s before a readingof th
8、e foam volume is taken.7.3 Number of Tests Each test solution should be tested intriplicate, using a freshly prepared test solution for each test.8. Test Procedure8.1 Prepare three 50-mL samples of a 30 % by volume(15-mL) coolant solution in deionized water. Use 100-mLgraduated cylinders.8.2 The gra
9、duated cylinders should be stoppered and placedin the constant 20 6 1C temperature water bath. Ensure thatthe test solution is submerged below the water level. Allow thetest solutions to equilibrate in the bath for 30 min.8.3 Remove the graduated cylinder from the bath and shakevigorously (using for
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD492119952006STANDARDTESTMETHODFORFOAMINGTENDENCIESOFENGINECOOLANTSATROOMTEMPERATURE 室温 下发 动机 冷却剂

链接地址:http://www.mydoc123.com/p-518401.html