ASTM D4733-2013 Standard Test Methods for Solventless Electrical Insulating Varnishes《无溶剂电绝缘清漆标准试验方法》.pdf
《ASTM D4733-2013 Standard Test Methods for Solventless Electrical Insulating Varnishes《无溶剂电绝缘清漆标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4733-2013 Standard Test Methods for Solventless Electrical Insulating Varnishes《无溶剂电绝缘清漆标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4733 03 (Reapproved 2009)D4733 13 An American National StandardStandard Test Methods forSolventless Electrical Insulating Varnishes1This standard is issued under the fixed designation D4733; the number immediately following the designation indicates the year oforiginal adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 These test methods cover solventless varnishes used primarily as electrical,
3、mechanical, and environmental protection forelectrical equipment.1.2 These test methods are used on solventless varnishes that are applied by dipping (at atmospheric pressure conditions orunder vacuum or other certain pressure), spraying, or brushing for the purpose of impregnating or sealing electr
4、ical equipment. Thefollowing test methods are included:Property Tests (Uncured): SectionDensity 7Flash Point 8Gel Time 9Monomer Content 10Rheological Properties (Non-Newtonian) 11Brookfield Viscosity 12Performance Property Tests (cured):Bond Strength 13Coating Thickness 14Dielectric Strength 15Diele
5、ctric Strength-Using Metal Panels 16Permittivity and Dissipation Factor 17Build 181.3 The values stated in inch-pound units are to be regarded as the standard. The values in parentheses are for information only.1.4 This standard does not purport to address all of the safety concerns, if any, associa
6、ted with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. Specific hazard statements are given in 8.3, 15.5.1, and 15.5.2.NOTE 1This test method is related to IEC
7、60455. Since both methods contain multiple test procedures, many procedures are technically equivalentwhile others differ significantly.2. Referenced Documents2.1 ASTM Standards:2D93 Test Methods for Flash Point by Pensky-Martens Closed Cup TesterD115 Test Methods for Testing Solvent Containing Varn
8、ishes Used for Electrical InsulationD149 Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials atCommercial Power FrequenciesD150 Test Methods for AC Loss Characteristics and Permittivity (Dielectric Constant) of Solid Electrical InsulationD168
9、 Test Method for Coke Residue of Creosote (Withdrawn 2006)3D374 Test Methods for Thickness of Solid Electrical Insulation (Withdrawn 2013)3D923 Practices for Sampling Electrical Insulating LiquidsD1475 Test Method For Density of Liquid Coatings, Inks, and Related ProductsD1711 Terminology Relating t
10、o Electrical InsulationD2196 Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational (Brookfield type) Viscometer1 These test methods are under the jurisdiction ofASTM Committee D09 on Electrical and Electronic Insulating Materials and is the direct responsibility of Subcomm
11、itteeD09.01 on Electrical Insulating Varnishes, Powders and Encapsulating Compounds.Current edition approved Oct. 1, 2009April 1, 2013. Published February 2010April 2013. Originally approved in 1987. Last previous edition approved in 20032009 asD4733 03.D4733 03 (2009). DOI: 10.1520/D4733-03R09.10.1
12、520/D4733-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. ForAnnual Book ofASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical sta
13、ndard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM rec
14、ommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C
15、700, West Conshohocken, PA 19428-2959. United States1D2519 Test Method for Bond Strength of Electrical Insulating Varnishes by the Helical Coil TestD3056 Test Method for Gel Time of Solventless VarnishesD3278 Test Methods for Flash Point of Liquids by Small Scale Closed-Cup ApparatusD3312 Test Metho
16、d for Percent Reactive Monomer in Solventless VarnishesD3487 Specification for Mineral Insulating Oil Used in Electrical ApparatusD3636 Practice for Sampling and Judging Quality of Solid Electrical Insulating MaterialsD6054 Practice for Conditioning Electrical Insulating Materials for Testing (Withd
17、rawn 2012)3E176 Terminology of Fire StandardsD4733 1322.2 IEC StandardsIEC 60455 Resin Based Reactive Compunds Used for Electrical Insulation3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in these test methods, refer to Terminology D1711. For definitions of terms associated withfi
18、re issues, refer to Terminology E176.3.1.2 gel time, nof solventless varnish, the time required at a specified temperature for a solventless varnish to be transformedfrom a liquid state to a gel as measured with a suitable gel time apparatus.3.1.3 thixotropy, nthe property of a material to thin upon
19、 isothermal agitation and to thicken upon subsequent rest.3.1.4 varnish, electrical insulating, na liquid resin system that is applied to and cured on electrical components providingelectrical, mechanical, and environmental protection.3.1.4.1 DiscussionThere are two types of electrical insulating va
20、rnishsolvent-containing and solventless. The solvent-containing varnish issolution, dispersion, or emulsion of a polymer or a mixture of polymers in a volatile, nonreactable liquid. The solventless type isa liquid resin system free of volatile, nonreactable solvents.4. Significance and Use4.1 The te
21、st methods referenced in these test methods are useful for control purposes during the manufacture and use ofsolventless varnishes.5. Sampling5.1 Accurate sampling, whether of the complete contents or only parts thereof, is extremely important from the standpoint ofevaluating the quality of the prod
22、uct sampled. In most cases, the detection of contaminants that are not ordinarily disperseduniformly through the liquid being sampled such as water or solid particles, necessitates taking samples at specific locations wherethe contaminants are likely to be found. For a liquid having a specific gravi
23、ty less than one, water and other impurities are mostlikely to be found on the bottom; whereas in the case of liquids having a specific gravity greater than one, these impurities are mostlikely to be found on the surface.5.2 Sampling Fluids Exhibiting Newtonian Viscosity:5.2.1 Sample solventless var
24、nishes having an approximate viscosity of 25 cP (0.025 Pas) or less at 100F (37.8C) using thesampling device shown in Fig. 1 of Test Method D923. However, if the temperature of the material is below room temperatureor if the humidity is above 75 % relative humidity, sample using an aspirator-type sa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD47332013STANDARDTESTMETHODSFORSOLVENTLESSELECTRICALINSULATINGVARNISHES 溶剂 绝缘 清漆 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-517832.html