1、Designation: D 4733 03An American National StandardStandard Test Methods forSolventless Electrical Insulating Varnishes1This standard is issued under the fixed designation D 4733; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover solventless varnishes usedprimarily as electrical, mechanical, and environmental pr
3、otec-tion for electrical equipment.1.2 These test methods are used on solventless varnishesthat are applied by dipping (at atmospheric pressure conditionsor under vacuum or other certain pressure), spraying, orbrushing for the purpose of impregnating or sealing electricalequipment. The following tes
4、t methods are included:Property Tests (Uncured): SectionDensity 7Flash Point 8Gel Time 9Monomer Content 10Rheological Properties (Non-Newtonian) 11Brookfield Viscosity 12Performance Property Tests (cured):Bond Strength 13Coating Thickness 14Dielectric Strength 15Dielectric Strength-Using Metal Panel
5、s 16Permittivity and Dissipation Factor 17Build 181.3 The values stated in inch-pound units are to be regardedas the standard. The values in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsi
6、bility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardstatements are given in 8.3, 15.5.1, and 15.5.2.NOTE 1This test method is related to IEC 60455. Since both methodscontain
7、multiple test procedures, many procedures are technically equiva-lent while others differ significantly.2. Referenced Documents2.1 ASTM Standards:2D 93 Test Methods for Flash-Point by Pensky-MartensClosed Cup TesterD 115 Test Methods for Testing Solvent Containing Var-nishes Used for Electrical Insu
8、lationD 149 Test Method for Dielectric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesD 150 Test Methods for A-C Loss Characteristics andPermittivity (Dielectric Constant) of Solid Electrical Insu-lating MaterialsD 168 Test Method for
9、Coke Residue of CreosoteD 374 Test Methods for Thickness of Solid Electrical Insu-latioD 923 Test Method for Sampling Electrical Insulating Liq-uidsD 1475 Test Method for Density of Paint, Varnish, Lacquer,and Related ProductsD 1711 Terminology Relating to Electrical InsulationD 2196 Test Methods fo
10、r Rheological Properties of Non-Newtonian Materials by Rotational (Brookfield) Viscom-eterD 2519 Test Method for Bond Strength of Electrical Insu-lating Varnishes by the Helical Coil TestD 3056 Test Method for Gel Time of Solventless VarnishesD 3278 Test Method for Flash Point of Liquids by SmallSca
11、le Closed-Cup ApparatusD 3312 Test Method for Percent Reactive Monomer inSolventless VarnishesD 3487 Specification for Mineral Insulating Oil Used inElectrical Apparatus6D 3636 Practice for Sampling and Judging Quality of SolidElectrical Insulating MaterialsD 6054 Practice for Conditioning Electrica
12、l Insulating Ma-terials for Testing2.2 IEC StandardsIEC 60455 Resin Based Reactive Compunds Used for1These test methods are under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.01 on Electrical Insulating Va
13、rnishes, Powders, and Encapsu-lating Compounds.Current edition approved Oct. 1, 2003. Published November 2003. Originallyapproved in 1987. Last previous edition approved in 1998 as D 4733 98.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serv
14、iceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Electrical Insulation3. Terminology3.1 Definitions: For
15、 definitions of terms used in these testmethods, refer to Terminology D 1711.3.1.1 gel time, nof solventless varnish, the time requiredat a specified temperature for a solventless varnish to betransformed from a liquid state to a gel as measured with asuitable gel time apparatus.3.1.2 thixotropy, nt
16、he property of a material to thin uponisothermal agitation and to thicken upon subsequent rest.3.1.3 varnish, electrical insulating, na liquid resin systemthat is applied to and cured on electrical components providingelectrical, mechanical, and environmental protection.3.1.3.1 DiscussionThere are t
17、wo types of electrical insu-lating varnishsolvent-containing and solventless. Thesolvent-containing varnish is solution, dispersion, or emulsionof a polymer or a mixture of polymers in a volatile, nonre-actable liquid. The solventless type is a liquid resin system freeof volatile, nonreactable solve
18、nts.4. Significance and Use4.1 The test methods referenced in these test methods areuseful for control purposes during the manufacture and use ofsolventless varnishes.5. Sampling5.1 Accurate sampling, whether of the complete contents oronly parts thereof, is extremely important from the standpointof
19、 evaluating the quality of the product sampled. In most cases,the detection of contaminants that are not ordinarily disperseduniformly through the liquid being sampled such as water orsolid particles, necessitates taking samples at specific locationswhere the contaminants are likely to be found. For
20、 a liquidhaving a specific gravity less than one, water and otherimpurities are most likely to be found on the bottom; whereasin the case of liquids having a specific gravity greater than one,these impurities are most likely to be found on the surface.5.2 Sampling Fluids Exhibiting Newtonian Viscosi
21、ty:5.2.1 Sample solventless varnishes having an approximateviscosity of 25 cP (0.025 Pas) or less at 100F (37.8C) usingthe sampling device shown in Fig. 1 of Test Method D 923.However, if the temperature of the material is below roomtemperature or if the humidity is above 75 % relative humidity,samp
22、le using an aspirator-type sampling device as shown inFig. 2 of Test Method D 923.5.2.2 Sample solventless varnishes having a viscosity from25 to 650 cP (0.025 to 0.65 Pas) at 100F (37.8C) and wherecontact with the atmosphere must be avoided, use a pressure-type sampling device as shown in Fig. 3 of
23、 Test Method D 923.5.2.3 Sample solventless varnishes having a viscosity above650 cP at 100F at 73 6 10F (23 6 5C). Open the containerand mix slowly so as not to entrap air. When the material ishomogeneous, take samples from two or three places on thesurface and mix together.5.3 Sampling Fluids Exhi
24、biting Non-Newtonian Viscosity:5.3.1 Sample solventless varnishes exhibiting non-Newtonian viscosity in accordance with 5.2.3.5.4 Use sample containers and sampling procedures inaccordance with Test Method D 923.5.5 When a sampling method is needed to determinewhether a lot meets the requirements of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD47332003STANDARDTESTMETHODSFORSOLVENTLESSELECTRICALINSULATINGVARNISHES 溶剂 绝缘 清漆 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-517830.html