《ASTM D4627-1992(2007) Standard Test Method for Iron Chip Corrosion for Water-Dilutable Metalworking Fluids《水溶性金属加工液的铁片腐蚀用标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4627-1992(2007) Standard Test Method for Iron Chip Corrosion for Water-Dilutable Metalworking Fluids《水溶性金属加工液的铁片腐蚀用标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4627 92 (Reapproved 2007)An American National StandardStandard Test Method forIron Chip Corrosion for WaterDilutable MetalworkingFluids1This standard is issued under the fixed designation D 4627; the number immediately following the designation indicates the year oforiginal adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers evaluation of the ferrous cor-rosion control characte
3、ristics of waterdilutable metalworkingfluids.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility
4、of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Summary of Test Method2.1 Cast iron chips are placed in a petri dish containing afilter paper and diluted metalworking fluid. The dish is cove
5、redand allowed to stand overnight. The amount of rust stain on thefilter paper is an indication of the corrosion control provided bythe fluid.3. Significance and Use3.1 The results obtained by this test are a useful guideline indetermining the ability of water diluted metalworking fluids toprevent o
6、r minimize rust under specific conditions. There isusually a relationship between the results of this test and asimilar ability of the subject coolant to prevent rust on nestedparts or in drilled holes containing chips, etc. It must beunderstood, however, that conditions, metal types, etc. found inp
7、ractice will not correlate quantitatively with these controlledlaboratory conditions. The procedure may not be able todifferentiate between two products with poor rust control dueto the wide spacing between test dilutions.4. Apparatus4.1 Disposable Petri Dishes, 35 by 10 mm plastic, with lidsNo. 8-7
8、57-100A.4.2 Glass-Fiber Filter Paper, Whatman No. 934-AH,3.2-cm diameter.4.3 Glass Stirring Rod.4.4 Spatula.4.5 Pipettes, 5 mL.4.6 Glass Bottle, 4-oz. with cap.4.7 Balance, accurate to 1 mg.4.8 Graduated Cylinder,50mL.4.9 Volumetric Flask,1L.4.10 Forceps.4.11 U.S. Standard Sieve, 18-mesh (1.0-mm sie
9、ve open-ings), stainless steel.5. Reagents and Materials5.1 Gray Cast Iron Drilling Chips.2NOTE 1The chips are made from Class 30 gray cast iron, as cast. Thestructure is mostly pearlite with small amounts of ferrite and type Agraphite. Brinell hardness is 179217. The chips are made using a clean,oi
10、l free jobbers length high speed drill of 29/64 in. diameter with 118plain point, 29 helix and 1215 clearance. Rotational speed should be500 rpm at a feed rate of 0.015 in./rev. Hand feeding is not permissible.The chips are sieved on 5 and 18-mesh sieves and those retained on the18-mesh sieve are im
11、mediately stored in airtight pint glass bottles. Eachdrilling is given a batch number. The bottle labels bear this batch numberand the date of filling.5.2 Synthetic Hard Water, 20,000 mg/L stock solutionprepared by dissolving 29.4 g reagent grade (ACS standard)CaCl22H2O in 1 L of freshly boiled dist
12、illed water.Amoderatehardness water is necessary in this test (100 ppm as CaCO3,71mg/L as chloride), and can be prepared at the time of the testby diluting the stock hard water 0.5 % in distilled water.5.3 Metalworking Fluid of Interest.6. Preparation of Diluted Metalworking Fluid6.1 Prepare 50 mL o
13、f fluid at each desired concentration byweight % in the 100 mg/L hardness water described above. Thewater must be at room temperature as described in 7.1. Alwaysadd the metalworking fluid concentrates into the water.6.2 The dilutions tested will be in weight % as follows:0.5, 1, 1.5, 2, 2.5, 3, 4, 5
14、, 7 and 10 %1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.L0.01 on Metal Removal Fluids and Lubricants.Current edition approved May 1, 2007. Published July 2007. Originally approvedin 1986. La
15、st previous edition approved in 2002 as D 462792 (2002).2The sole source of supply of the drilling chips known to the committee at thistime is Techsolve, Technical Center, 1111 Edison Drive, Cincinnati, OH 45216-2265. If you are aware of alternative suppliers, please provide this information toASTM
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD462719922007STANDARDTESTMETHODFORIRONCHIPCORROSIONFORWATERDILUTABLEMETALWORKINGFLUIDS 水溶性 金属加工 铁片

链接地址:http://www.mydoc123.com/p-517530.html