ASTM D4206-1996(2018) Standard Test Method for Sustained Burning of Liquid Mixtures Using the Small Scale Open-Cup Apparatus.pdf
《ASTM D4206-1996(2018) Standard Test Method for Sustained Burning of Liquid Mixtures Using the Small Scale Open-Cup Apparatus.pdf》由会员分享,可在线阅读,更多相关《ASTM D4206-1996(2018) Standard Test Method for Sustained Burning of Liquid Mixtures Using the Small Scale Open-Cup Apparatus.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4206 96 (Reapproved 2018)Standard Test Method forSustained Burning of Liquid Mixtures Using the Small ScaleOpen-Cup Apparatus1This standard is issued under the fixed designation D4206; the number immediately following the designation indicates the year oforiginal adoption or, in the ca
2、se of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method may be used in conjunction with a flash point determination. If the flash
3、 point ofa mixture of flammable and nonflammable liquids or liquids of widely different flash points is belowthe upper limit of a flammability classification (for example, 100F specified by the U.S. Departmentof Transportation), this test may be conducted to determine the sustained burning character
4、istics of themixture.This test method is a modification of the test for combustibility now incorporated as Schedule 2 ofthe “Highly Flammable Liquids and Liquefied Petroleum Gases Regulation, 1972” of the UnitedKingdom under The FactoriesAct, 1961, which is also issued as British Standard BS-3900, P
5、artA-11,Small Scale Test for Combustibility. This sustained burning test was studied and proposed by theASTM Coordinating Committee for Flash Point and Related Properties. The major purpose of this testis similar to that of the British testto provide a method for determining the sustained burningcha
6、racteristics by directly observing this property rather than by deducing them from the flash point.1. Scope1.1 This test method2describes a procedure for determiningthe sustained burning characteristics of mixtures of flammableand nonflammable liquids and to mixtures containing liquidswith widely di
7、fferent flash points.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard should be used to measure and describethe resp
8、onse of materials, products, or assemblies to heat andflame under controlled conditions and should not be used todescribe or appraise the fire-hazard or fire-risk of materials,products, or assemblies under actual fire conditions. However,results of the test may be used as elements of a fire-hazardas
9、sessment or a fire-risk assessment which takes into accountall of the factors which are pertinent to an assessment of thefire hazard or fire risk of a particular end use.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility
10、of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization estab
11、lished in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 British Standards:3BS-3900 Part A-11, Small Scale Test for Combustibility3. Sum
12、mary of Test Method3.1 Ablock of aluminum alloy, or other nonrusting metal ofsuitable heat conductivity, with a concave depression (calledthe well) is heated to the required temperature of 120F (49C).A standard source of flame, capable of being swung over thecenter of the well and at a given distanc
13、e from it, is attached tothe metal block.1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition approved June
14、 1, 2018. Published June 2018. Originallyapproved in 1982. Last previous edition approved in 2013 as D4206 96 (2013).DOI: 10.1520/D4206-96R18.2McKelvie, A. N., “A Test for Ability to Support Combustion for LiquidsIncluding Paints and Allied Products,” Journal of Oil Co. Chemical Assoc., 1972,Vol 55,
15、 pp. 10861095.3Available from British Standards Institute (BSI), 389 Chiswick High Rd.,London W4 4AL, U.K., http:/www.bsi- orAmerican National StandardsInstitute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700
16、, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the Wor
17、ld Trade Organization Technical Barriers to Trade (TBT) Committee.13.2 Two millilitres of the product under test are transferredto the well. After the product has reached the statedtemperature, the flame is passed over the well, held there for aspecified time, and then removed. The time of sustained
18、burning is then noted.4. Significance and Use4.1 Mixtures of flammable liquids and nonflammableliquids, such as an alcohol and water mixture, are classified bythe U. S. Government by the definition of flammable liquidbased on a closed-cup flash point method. Thus, mixtures maybe classed as flammable
19、 even though they do not sustainburning. This test method determines the ability of a liquidmixture to sustain burning and, when used with a closed-cupflash point method, indicates the flammability characteristics ofthe mixture.5. Apparatus5.1 Small Scale Open-Cup Apparatus,4or an equivalenttester c
20、onsisting of a 316 stainless steel block or othernonrusting block of suitable heat conductivity, fitted with aconcave depression or well (Note 1). The metal block has athermometer embedded in it. A small gas jet on a swivel isattached to the metal block. The exact dimensions of the metalblock and it
21、s well, the gas jet and its positioning, and theembedded thermometer are shown in Fig. 1 and are specified inAnnex A1.NOTE 1While the Small Scale Open-Cup Tester is generally made ofan aluminum alloy, continued use of it for sustained burning tests mayproduce a carbon deposit in the well that may be
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD420619962018STANDARDTESTMETHODFORSUSTAINEDBURNINGOFLIQUIDMIXTURESUSINGTHESMALLSCALEOPENCUPAPPARATUSPDF

链接地址:http://www.mydoc123.com/p-516542.html