1、Designation: D4086 92a (Reapproved 2012)Standard Practice forVisual Evaluation of Metamerism1This standard is issued under the fixed designation D4086; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A nu
2、mber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONBecause perceived color involves the spectral characteristics of source, object, and eye, differentcombinations of spectral characteristi
3、cs can evoke the same color sensation. For this reason,metamerism has been described as “invisible spectral differences.”Apair of specimens is said to be metameric when the specimens match under one set of illuminatingand viewing conditions and do not match under another set. For this condition to e
4、xist, there must bedifferences in spectral character of specimens and sources or specimens and observers. There may bemore than one condition under which the specimens match, as well as more than one for which theyare a mismatch. Similarly, two specimens may be a near-match under one set of conditio
5、ns, and underanother set the direction and magnitude of the color difference may change.1. Scope1.1 This practice describes visual methods for detectingmetamerism and for estimating the magnitude of a metamericcolor difference.1.2 The practice is limited to the consideration of illuminantmetamerism
6、and observer metamerism. It is not designed tocover so-called geometric metamerism, in which members ofspecimen pairs change relative appearance as the angles ofillumination and viewing are changed, for example, becausethey incorporate flake metal or pearlescent colorants.1.3 This practice does not
7、provide for the computation ofindices of metamerism based upon instrumental measurementof spectral characteristics.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate
8、safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2616 Test Method for Evaluation of Visual Color Differ-ence With a Gray Scale (Withdrawn 2012)3E284 Terminology of Appearance3. Terminology3.1 Definitions o
9、f appearance terms used in this practicemay be found in Terminology E284.3.2 Definitions:3.2.1 metamerism, nproperty of two specimens that matchunder a specified illuminator and to a specified observer andwhose spectral reflectances or transmittances differ in thevisible wavelengths.3.2.1.1 Discussi
10、onAs a consequence of the required dif-ference, the two specimens may not match under a differentilluminator or to a different observer. Similar considerationsapply to two lights matching to a specified observer but not toother observers. (E284)3.2.2 paramerism, nphenomenon in which specimenshaving
11、different spectrophotometric curves produce approxi-mately the same color sensation under the same illuminatingand viewing conditions. (E284)4. Significance and Use4.1 Metameric color matches result from the use of differentcolorants (pigments, dyes, and the like) in achieving the samecolor match. U
12、sually, the purchaser requires that the colormatch be nonmetameric; this practice permits this requirementto be quickly tested in both field and laboratory. Where1This practice is under the jurisdiction of ASTM Committee E12 on Color andAppearance and is the direct responsibility of Subcommittee E12
13、.11 on VisualMethods.Current edition approved July 1, 2012. Published August 2012. Originallyapproved in 1982. Last previous edition approved in 2007 as D4086 92a (2007).DOI: 10.1520/D4086-92AR12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at
14、 serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohock
15、en, PA 19428-2959. United States1nonmetameric matches are not possible or practicable, for costor other reasons, some limitation of metamerism may berequired. The procedures for estimating the magnitude ofmetamerism described in this practice provide methods forassessing the effectiveness of such li
16、mitation.5. Test Specimens5.1 This practice does not cover the preparation of testspecimens. The method shall be agreed upon between thepurchaser and the seller.6. Procedure for Visual Detection of Metamerism6.1 Illuminant MetamerismAfter observing that a pair ofspecimens is a visual match under one
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD40861992A2012STANDARDPRACTICEFORVISUALEVALUATIONOFMETAMERISM 变异 外观 鉴定 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-516253.html