ASTM D3985-2017 Standard Test Method for Oxygen Gas Transmission Rate Through Plastic Film and Sheeting Using a Coulometric Sensor《用库仑探测器测量氧气通过塑料薄膜和薄板的传送率的标准试验方法》.pdf
《ASTM D3985-2017 Standard Test Method for Oxygen Gas Transmission Rate Through Plastic Film and Sheeting Using a Coulometric Sensor《用库仑探测器测量氧气通过塑料薄膜和薄板的传送率的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3985-2017 Standard Test Method for Oxygen Gas Transmission Rate Through Plastic Film and Sheeting Using a Coulometric Sensor《用库仑探测器测量氧气通过塑料薄膜和薄板的传送率的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3985 17Standard Test Method forOxygen Gas Transmission Rate Through Plastic Film andSheeting Using a Coulometric Sensor1This standard is issued under the fixed designation D3985; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedure for determinationof the steady-state rate of transmission of
3、 oxygen gas throughplastics in the form of film, sheeting, laminates, coextrusions,or plastic-coated papers or fabrics. It provides for the determi-nation of (1) oxygen gas transmission rate (OTR), (2) thepermeance of the film to oxygen gas (PO2), and (3) oxygenpermeability coefficient (PO2) in the
4、case of homogeneousmaterials.1.2 This test method does not purport to be the only methodfor measurement of OTR. There may be other methods of OTRdetermination that use other oxygen sensors and procedures.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement a
5、re included in thisstandard.1.4 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations
6、prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization Technic
7、alBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1434 Test Method for Determining Gas Permeability Char-acteristics of Plastic Film and SheetingD1898 Practice for Sampling of Plastics (Withdrawn 1998)3E691 Practice for Conducting an Interlaboratory Study toDetermine th
8、e Precision of a Test MethodF1927 Test Method for Determination of Oxygen Gas Trans-mission Rate, Permeability and Permeance at ControlledRelative Humidity Through Barrier Materials Using aCoulometric Detector3. Terminology3.1 Definitions:3.1.1 oxygen permeability coeffcient (PO2)the product ofthe p
9、ermeance and the thickness of film. The permeability ismeaningful only for homogeneous materials, in which case it isa property characteristic of the bulk material. This quantityshould not be used, unless the relationship between thicknessand permeance has been verified on tests using several differ
10、entthicknesses of the material. The SI unit of oxygen permeabilityis the mol/(msPa). The test conditions (see 3.1.3) must bestated.3.1.2 oxygen permeance (PO2)the ratio of the OTR to thedifference between the partial pressure of O2on the two sidesof the film. The SI unit of permeance is the mol/(m2s
11、Pa). Thetest conditions (see 5.1) must be stated.3.1.3 oxygen transmission rate (OTR)the quantity ofoxygen gas passing through a unit area of the parallel surfacesof a plastic film per unit time under the conditions of test. TheSI unit of transmission rate is the mol/(m2s). The testconditions, inclu
12、ding temperature and oxygen partial pressureon both sides of the film must be stated.3.1.3.1 A commonly used unit of OTR is the cm3(STP)/(m2d) at one atmosphere pressure difference where 1 cm3(STP) is 44.62 mol, 1 atm is 0.1013 MPa, and one day is86.4 103s.The OTR in SI units is obtained by multiply
13、ing thevalue in inch-pound units by 5.163 1010.4. Summary of Test Method4.1 The oxygen gas transmission rate is determined after thesample has equilibrated in a dry test environment. In this1This test method is under the jurisdiction ofASTM Committee F02 on PrimaryBarrier Packaging and is the direct
14、 responsibility of Subcommittee F02.10 onPermeation.Current edition approved Nov. 15, 2017. Published December 2017. Originallyapproved in 1981. Last previous edition approved in 2010 as D3985 05 (2010)1.DOI: 10.1520/D3985-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orco
15、ntact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive
16、, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issu
17、ed by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1context, a “dry” environment is considered to be one in whichthe relative humidity is less than 1 %.4.2 The specimen is mounted as a sealed semi-barrierbetween two chambers at ambient atmospheric pressure. Onechamber is
18、slowly purged by a stream of nitrogen and the otherchamber contains oxygen. As oxygen gas permeates throughthe film into the nitrogen carrier gas, it is transported to thecoulometric detector where it produces an electrical current,the magnitude of which is proportional to the amount ofoxygen flowin
19、g into the detector per unit time.5. Significance and Use5.1 The OTR is an important determinant of the packagingprotection afforded by barrier materials. It is not, however, thesole determinant, and additional tests, based on experience,must be used to correlate packaging performance with OTR. Itis
20、 suitable as a referee method of testing, provided that thepurchaser and the seller have agreed on sampling procedures,standardization procedures, test conditions, and acceptancecriteria.5.2 Limited statistical data on correlations with Test MethodD1434 methods are available4; however, the oxygen tr
21、ansmis-sion rate of a standard reference material (see 12.1)asdetermined manometrically by NIST, is in good agreementwith the values obtained in the coulometric interlaboratory testusing material from the same manufacturing lot. Thus, this testmethod may be used as a referee method.6. Interferences6
22、.1 The presence of certain interfering substances in thecarrier gas stream may give rise to unwanted electrical outputsand error factors. Interfering substances include free chlorineand some strong oxidizing agents. Exposure to carbon dioxideshould also be minimized to avoid damage to the sensorthro
23、ugh reaction with the potassium hydroxide electrolyte.7. Apparatus7.1 Oxygen Gas Transmission Apparatus, as diagrammed inFig. 1 with the following:7.1.1 Diffusion Cell shall consist of two metal halves,which, when closed upon the test specimen, will accuratelydefine a circular area. The volume enclo
24、sed by each cell half,when clamped, is not critical; it should be small enough toallow for rapid gas exchange, but not so small that anunsupported film which happens to sag or bulge will contactthe top or bottom of the cell. The diffusion cell shall beprovided with a thermometer well for measuring t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD39852017STANDARDTESTMETHODFOROXYGENGASTRANSMISSIONRATETHROUGHPLASTICFILMANDSHEETINGUSINGACOULOMETRICSENSOR

链接地址:http://www.mydoc123.com/p-515970.html