ASTM D3717-1985a(2015) Standard Test Method for Low Concentrations of Antimony in Paint by Atomic Absorption Spectroscopy《采用原子吸收光谱法测定涂料中低浓度锑的标准试验方法》.pdf
《ASTM D3717-1985a(2015) Standard Test Method for Low Concentrations of Antimony in Paint by Atomic Absorption Spectroscopy《采用原子吸收光谱法测定涂料中低浓度锑的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3717-1985a(2015) Standard Test Method for Low Concentrations of Antimony in Paint by Atomic Absorption Spectroscopy《采用原子吸收光谱法测定涂料中低浓度锑的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3717 85a (Reapproved 2015)Standard Test Method forLow Concentrations of Antimony in Paint by AtomicAbsorption Spectroscopy1This standard is issued under the fixed designation D3717; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the contentof antimony in the range between 50 a
3、nd 200 ppm (mg/kg)present in the solids of liquid coatings or in dried filmsobtained from previously coated substrates. There is no reasonto believe that higher levels could not be determined by thistest method, provided that appropriate dilutions and adjust-ments in specimen size and reagent quanti
4、ties are made.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to
5、establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardstatements are given in Section 7.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD2832 Guide for Determining Volatile and Nonvol
6、atile Con-tent of Paint and Related Coatings3. Summary of Test Method3.1 The sample of liquid coating or dried film is preparedfor analysis by dry ashing at 500C, followed by refluxing withhydrochloric acid and stannous chloride. The antimony contentof the acid extract is determined by atomic absorp
7、tion spec-troscopy.4. Significance and Use4.1 The permissible level of heavy metals in certain coat-ings is specified by governmental regulatory agencies. This testmethod provides a fully documented procedure for determininglow concentrations of antimony present in both water- andsolvent-reducible c
8、oatings to determine compliance.5. Apparatus5.1 Atomic Absorption Spectrophotometer, consisting of anatomizer and either a single- or three-slot burner; gas pressureregulating and metering devices for air and acetylene; anantimony source lamp with a regulated constant current supply;a monochromator
9、and associated optics; a photosensitivedetector connected to an electronic amplifier; and a readoutdevice.5.2 Muffle Furnace, maintained at 500 6 10C.5.3 Oven, maintained at 105 6 2C.5.4 Hot-Plate, with variable surface temperature controlover the range from 70 to 200C.5.5 Reflux Condenser, water-co
10、oled, and fitted with astandard-taper joint.5.6 Erlenmeyer Flask, 125-mL, with standard-taper joint tofit condenser.5.7 Volumetric Flasks, 100 and 1000-mL.5.8 Dropping Bottles, 8 or 15-mL (14 or12-oz) capacity.5.9 Glass or Disposable Syringes, 10-mL capacity.5.10 Pipets, 1, 5, 10, and 15-mL capacity
11、.5.11 Filter Paper, ashless, medium or slow filtering.5.12 Paint Shaker.5.13 Paint Draw-Down Bar.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on An
12、alytical Reagents of the American Chemical Society,1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition app
13、roved June 1, 2015. Published June 2015. Originallyapproved in 1978. Last previous edition approved in 2010 as D3717 85a (2010).DOI: 10.1520/D3717-85AR15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMS
14、tandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1where such specifications are available.3Other grades may beused, provided it is first ascert
15、ained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent grade waterconforming to Type II of Specification D1193.6.3 Antimony Standar
16、d Stock Solution (0.1 mg/mL)Dissolve 0.1000 g of antimony metal in 40 mL of sulfuric acid(H2SO4, sp gr 1.84) by heating. Cool, carefully transferquantitatively to a 1-L volumetric flask already approximatelyhalf full with water, allow to cool to room temperature, anddilute to 1 L.6.4 Hydrochloric Ac
17、id (sp gr 1.19)Concentrated hydro-chloric acid (HCl).6.5 Stannous Chloride Solution (400 g/L in HCl)Dissolve40 g of tin (II) chloride (SnCl2) in 50 mL of HCl (sp gr 1.19).Transfer to a 100-mL volumetric flask and fill to the mark withconcentrated HCl.7. Hazards7.1 Use care in handling concentrated H
18、Cl because it iscorrosive and may cause burns to the skin and eyes and itsvapor is irritating to mucous membranes. Refer to suppliersSafety Data Sheet.7.2 Use only a rubber bulb aspirator for pipetting liquids.8. Calibration and Standardization8.1 Prepare 100-mL quantities of at least four standards
19、olutions bracketing the expected antimony concentration inthe sample to be tested. To suitable aliquots of the 0.1 mg/mLstandard antimony solution, add 40 mL of concentrated HCland 8 drops of SnCl2solution. Dilute to 100 mL with water.Prepare a blank solution by diluting 40 mL of concentratedHCl and
20、 8 drops of SnCl2solution to 100 mL with water.8.2 Operational instructions for atomic absorption spectro-photometers vary with different models. Consult the manufac-turers literature for establishing optimum conditions for thespecific instrument used.8.3 Turn the instrument on and set the wavelengt
21、h to the217.6-nm antimony line. Apply the recommended current tothe antimony source lamp. Allow the instrument to warm upfor about 15 min and set the slit width. Adjust the air andacetylene pressures and ignite the burner in accordance withinstructions.8.4 Aspirate water to rinse the atomizer chambe
22、r. Aspirate astandard solution and make any necessary readjustment ininstrument parameters to obtain maximum absorption.8.5 Aspirate the blank solution. When the recorder, meter,or other readout device reaches a constant value, it should beimmediately zeroed. Repeat this blank determination until as
23、teady, repeatable zero value is obtained at the maximumresponse.8.6 Aspirate each of the appropriate standard solutions inascending antimony concentrations and record the correspond-ing instrument readings.Aspirate water between each standard.NOTE 1A deuterium background corrector, if available, sho
24、uld beused to correct for background absorption. If not available, it is necessaryto reaspirate each standard solution and measure the background at anearby nonabsorbing region of the spectrum.NOTE 2Because of the high concentration and corrosive nature of theacids used for the analysis, it is essen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD37171985A2015STANDARDTESTMETHODFORLOWCONCENTRATIONSOFANTIMONYINPAINTBYATOMICABSORPTIONSPECTROSCOPY

链接地址:http://www.mydoc123.com/p-515336.html