ASTM D3617-2007 Standard Practice for Sampling and Analysis of Built-Up Roof Systems During Application《施用中组合屋顶系统的取样和分析用标准实施规程》.pdf
《ASTM D3617-2007 Standard Practice for Sampling and Analysis of Built-Up Roof Systems During Application《施用中组合屋顶系统的取样和分析用标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3617-2007 Standard Practice for Sampling and Analysis of Built-Up Roof Systems During Application《施用中组合屋顶系统的取样和分析用标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3617 07Standard Practice forSampling and Analysis of Built-Up Roof Systems DuringApplication1This standard is issued under the fixed designation D 3617; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This practice is a guide for removing s
3、pecimens forbuilt-up bituminous roof systems during application, but beforethe application of flood coating and top surfacing, for deter-mining the approximate quantities of the components and thepossible presence of moisture, or dry spots between plies, inthe field. Components may consist of:1.1.1
4、Insulation, when part of the roof membrane system,1.1.2 Plies of roofing felt,1.1.3 Interply layers of bituminous material, and1.1.4 Top coating, if present, before any surfacing aggregatehas been applied.1.2 This practice is applicable to both 914-mm (36-in.) and1000-mm (3938-in.) wide felt rolls.1
5、.3 The values stated in SI (metric) units are to be regardedas the standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determi
6、ne the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 226 Specification for Asphalt-Saturated Organic FeltUsed in Roofing and WaterproofingD 227 Specification for Coal-Tar-Saturated Organic FeltUsed in Roofing and WaterproofingD 250 Specification f
7、or Asphalt-Saturated Asbestos FeltUsed in Roofing and Waterproofing3D 2178 Specification for Asphalt Glass Felt Used in Roof-ing and WaterproofingD 2626 Specification for Asphalt-Saturated and Coated Or-ganic Felt Base Sheet Used in RoofingD 3158 Specification for Asphalt Saturated and CoatedOrganic
8、 Felt Used in Roofing3D 3378 Specification for Asphalt-Saturated and Coated As-bestos Felt Base Sheet Used in Roofing33. Sampling3.1 Unless otherwise specified, take at least one specimenfor each separate roof, plus one for each 929 m2(10 000 ft2);take specimens at random.3.2 Take additional specime
9、ns in which deficiencies areindicated in the membrane to determine the extent of thedeficient area.4. Test Specimen4.1 Sweep the surface of the membrane clean where eachtest specimen will be taken.4.2 For determining approximate quantities of components,cut a 300- by 300-mm (12- by 12-in.) specimen
10、from themembrane using a template (Fig. 1).4.2.1 If the membrane is adhered to the insulation, removethe membrane with the adhering insulation.4.2.2 If the membrane is adhered directly to the roof deck,estimate the quantity of bitumen remaining on the deck afterthe specimen is removed.4.3 For the pu
11、rpose of determining the felt spacing, cut a100- by 111-mm (4- by 44-in.) rectangular specimen from themembrane, using a template (Fig. 1) placed at right angles tothe long dimension of the felts.4.4 Identify each specimen by location and record thepresence of insulation or the estimated quantity of
12、 bitumenremaining on the deck.1This practice is under the jurisdiction ofASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.20 on RoofingMembrane Systems.Current edition approved May 1, 2007. Published June 2007. Originallyapproved in 1977. Last previ
13、ous edition approved in 2002 as D 3617 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.1Copyrig
14、ht ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.5 If practicable, return the cut membrane specimen to itsoriginal location in the roof. Make adequate repairs to theroofing system, using at least the same number of felt plies asthe original
15、 roof membrane after testing.5. Procedure5.1 Remove insulation fully from the 300- by 300-mm (12-by 12-in.) specimen, if present, being careful to remove as littlebituminous material as possible or leave the insulation in placeand later use manufacturers information to correct for itsweight. Determi
16、ne the area of the specimen from three differ-ent measurements in each direction and weigh.5.2 Measure the individual felts and calculate the area ofeach ply as in 5.1 (as a result of lapping not all plies will be thesame size as the original specimen).5.3 Visually check along the sample edges for m
17、oisturewithin the membrane and skips or dry spots between layers offelt.DimensionSquare (4.2) Rectangular (4.3)mm in. mm in.A 300 12 100 4B 300 12 1000 40C 150 6 150 6D 40 1.5 40 1.5E 40 1.5 40 1.5F318 318FIG. 1 Dimensions of Templates for Roof SamplingTABLE 1 Computation Form and Sample Computation
18、 for a Nominal Four-Ply, Built-Up Roof Mopped to InsulationLineRefer-enceIdentification Factor Component Computation ExampleSIUnitslb/100ft2A1 5.1 original specimen measured area 0.314 3 0.312 = 0.098 m22 5.1 original specimen (with insulation) measured mass 749 g36.1approximate specimen mass/unit a
19、rea line (2)/line (1) 749/0.098 = 7640 g/m21564 5.2 individual felt areas sum of measuredareas0.046 + 3 (0.098)+ 0.065= 0.405 m25 6.2 number of plies line (4)/line (1) 0.405/0.098 = 4.13 plies6 6.3 total felt mass per unit area line (5) 3 (assumedfelt mass per unitarea)4.13 3 635 = 2620 g/m2547 5.1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD36172007STANDARDPRACTICEFORSAMPLINGANDANALYSISOFBUILTUPROOFSYSTEMSDURINGAPPLICATION 施用 组合 屋顶 系统

链接地址:http://www.mydoc123.com/p-515114.html