ASTM D3617 D3617M-2017 Standard Practice for Sampling and Analysis of Built-Up Roof Systems During Application《施用中组合屋顶系统的取样和分析用标准实施规程》.pdf
《ASTM D3617 D3617M-2017 Standard Practice for Sampling and Analysis of Built-Up Roof Systems During Application《施用中组合屋顶系统的取样和分析用标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3617 D3617M-2017 Standard Practice for Sampling and Analysis of Built-Up Roof Systems During Application《施用中组合屋顶系统的取样和分析用标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3617/D3617M 17Standard Practice forSampling and Analysis of Built-Up Roof Systems DuringApplication1This standard is issued under the fixed designation D3617/D3617M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This practice is a guid
3、e for removing specimens forbuilt-up bituminous roof systems during application, but beforethe application of flood coating and top surfacing, for deter-mining the approximate quantities of the components and thepossible presence of moisture, or dry spots between plies, inthe field. Components may c
4、onsist of:1.1.1 Insulation, when part of the roof membrane system,1.1.2 Plies of roofing felt,1.1.3 Interply layers of bituminous material, and1.1.4 Top coating, if present, before any surfacing aggregatehas been applied.1.2 This practice is applicable to both 914-mm 36-in. and1000-mm 3938-in. wide
5、felt rolls.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-confo
6、rmancewith the standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prio
7、r to use.2. Referenced Documents2.1 ASTM Standards:2D226/D226M Specification for Asphalt-Saturated OrganicFelt Used in Roofing and WaterproofingD227/D227M Specification for Coal-Tar-Saturated OrganicFelt Used in Roofing and WaterproofingD250 Standard Specification for Asphalt-Saturated AsbestosFelt
8、Used in Roofing and Waterproofing (Withdrawn1991)3D2178/D2178M Specification forAsphalt Glass Felt Used inRoofing and WaterproofingD2626/D2626M Specification for Asphalt-Saturated andCoated Organic Felt Base Sheet Used in RoofingD3158 Specification for Asphalt Saturated and Coated Or-ganic Felt Used
9、 in Roofing (Withdrawn 1983)3D3378 Specification for Asphalt-Saturated and Coated As-bestos Felt Base Sheet Used in Roofing (Withdrawn1985)33. Sampling3.1 Unless otherwise specified, take at least one specimenfor each separate roof, plus one for each 929 m210 000 ft2;take specimens at random.3.2 If
10、deficiencies are indicated in the membrane, additionalPractice D3617/D3617M test cuts shall be taken at fourlocations diagonally3 m 10 ft in each directionfrom theoriginal test cut and examined in the same manner as theoriginal test cut was examined.4. Test Specimen4.1 Sweep the surface of the membr
11、ane clean where eachtest specimen will be taken.4.2 For determining approximate quantities of components,cut a 300- by 300-mm 12- by 12-in. specimen from themembrane using a template (Fig. 1).4.2.1 If the membrane is adhered to the insulation, removethe membrane from the adhering insulation.4.2.2 If
12、 the membrane is adhered directly to the roof deck,estimate the quantity of bitumen remaining on the deck afterthe specimen is removed.1This practice is under the jurisdiction ofASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.20 on RoofingMembrane
13、Systems.Current edition approved Jan. 15, 2017. Published January 2017. Originallyapproved in 1977. Last previous edition approved in 2016 as D3617/D3617M 16.DOI: 10.1520/D3617_D3617M-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at servicea
14、stm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19
15、428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Tech
16、nical Barriers to Trade (TBT) Committee.14.3 For the purpose of determining the felt spacing, cut a100- by 111-mm 4- by 44-in. rectangular specimen from themembrane, using a template (Fig. 1) placed at right angles tothe long dimension of the felts.4.4 Identify each specimen by location and record t
17、hepresence of insulation or the estimated quantity of bitumenremaining on the deck.4.5 If practicable, return the cut membrane specimen to itsoriginal location in the roof. Make adequate repairs to theroofing system, using at least the same number of felt plies asthe original roof membrane after tes
18、ting.5. Procedure5.1 Remove insulation fully from the 300- by 300-mm 12-by 12-in. specimen, if present, being careful to remove as littlebituminous material as possible or leave the insulation in placeand later use manufacturers information to correct for itsweight. Determine the area of the specime
19、n from three differ-ent measurements in each direction and weigh.5.2 Measure the individual felts and calculate the area ofeach ply as in 5.1 (as a result of lapping not all plies will be thesame size as the original specimen).5.3 Visually check along the sample edges for moisturewithin the membrane
20、 and skips or dry spots between layers offelt.5.4 Determine the number of plies and lap spacing by visualexamination of the 100- by 1118-mm 4- by 44-in. specimen,if lap spacing is desired.6. Calculation (See Table 1 for Form and SampleComputation)6.1 Calculate the mass (weight) per unit area of the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD3617D3617M2017STANDARDPRACTICEFORSAMPLINGANDANALYSISOFBUILTUPROOFSYSTEMSDURINGAPPLICATION 施用 组合

链接地址:http://www.mydoc123.com/p-515113.html