ASTM D2464-2013 Standard Specification for Threaded Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings Schedule 80《加螺纹聚氯乙烯(PVC)塑料管配件的标准规格 表80》.pdf
《ASTM D2464-2013 Standard Specification for Threaded Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings Schedule 80《加螺纹聚氯乙烯(PVC)塑料管配件的标准规格 表80》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2464-2013 Standard Specification for Threaded Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings Schedule 80《加螺纹聚氯乙烯(PVC)塑料管配件的标准规格 表80》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2464 13 An American National StandardStandard Specification forThreaded Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings,Schedule 801This standard is issued under the fixed designation D2464; the number immediately following the designation indicates the year oforiginal adoption or, in
2、 the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 T
3、his specification covers poly(vinyl chloride) (PVC)threaded Schedule 80 pipe fittings. Included are requirementsfor materials, workmanship, dimensions, and burst pressure.NOTE 1Threaded CPVC plastic pipe fittings, Schedule 80, whichwere formerly included in this standard, are now covered by Specific
4、ationF437.1.2 The products covered by this specification are intendedfor use with the distribution of pressurized liquids only, whichare chemically compatible with the piping materials. Due toinherent hazards associated with testing components and sys-tems with compressed air or other compressed gas
5、es somemanufacturers do not allow pneumatic testing of their products.Consult with specific product/component manufacturers fortheir specific testing procedures prior to pneumatic testing.NOTE 2Pressurized (compressed) air or other compressed gasescontain large amounts of stored energy which present
6、 serious safetyhazards should a system fail for any reason.1.3 The text of this specification references notes, footnotes,and appendixes which provide explanatory material. Thesenotes and footnotes (excluding those in tables and figures) shallnot be considered as requirements of the specification.1.
7、4 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are providedfor information only.1.5 The following safety hazards caveat pertains only to thetest method portion, Section 7, of this specification. Thisstandard does not purport to address all
8、of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Condit
9、ioning Plastics for TestingD1599 Test Method for Resistance to Short-Time HydraulicPressure of Plastic Pipe, Tubing, and FittingsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) Co
10、mpoundsD2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsD2749 Symbols for Dimensions of Plastic Pipe FittingsF412 Terminology Relating to Plastic Piping SystemsF437 Specification for Threaded Chlorinated Poly(VinylChloride) (CPVC) Plastic Pipe Fittings, Schedule 80F149
11、8 Specification for Taper Pipe Threads 60 for Thermo-plastic Pipe and Fittings2.2 Federal Standard:Fed. Std. No. 123 Marking for Shipment (Civil Agencies)32.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage32.4 NSF Standard:Standard No. 14 for Plastic Piping Components and RelatedMate
12、rials4Standard No. 61 for Drinking Water Systems ComponentsHealth Effects43. Terminology3.1 GeneralDefinitions are in accordance with Terminol-ogy F412, and abbreviations are in accordance with Terminol-ogy D1600, unless otherwise indicated. The abbreviation forpoly(vinyl chloride) plastic is PVC.1T
13、his specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.10 on Fittings.Current edition approved May 1, 2013. Published May 2013. Originallyapproved in 1965. Last previous edition approved in 2006 as D2464 06. DOI
14、:10.1520/D2464-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents O
15、rder Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/dodssp.daps.dla.mil.4Available from NSF International, P.O. Box 130140, 789 N. Dixboro Rd., AnnArbor, MI 48113-0140, http:/www.nsf.org.*A Summary of Changes section appears at the end of this standardCopyright
16、 ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14. Classification4.1 GeneralThis specification covers threaded Schedule80 PVC pipe fittings, made from four PVC plastic compoundsand intended for use with threaded Iron Pipe Size (IPS)outside-dia
17、meter plastic pipe.4.1.1 Fittings covered by this specification are normallymolded. In-line fittings, such as couplings, unions, bushings,caps, nipples, etc., shall be molded or machined from extrudedstock.4.1.2 Fittings fabricated by back welding or butt fusion arenot included in this specification
18、.5. Materials and Manufacture5.1 This specification covers PVC pipe fittings made fromtwo PVC plastics as classified in Specification D1784. Theseare cell classifications 12454 and 14333.NOTE 3Mechanical strength, heat deflection temperature, and flam-mability requirements are covered in Specificati
19、on D1784.5.2 Rework MaterialThe manufacturers shall use onlytheir own clean rework fitting material and the fittings pro-duced shall meet all the requirements of this specification.6. Requirements6.1 Dimensions and Tolerances:6.1.1 The dimensions and tolerances of the fittings shall beas shown in Ta
20、ble 1 and Table 2 when measured in accordancewith Test Method D2122. Minimum dimensions have zeronegative tolerances. Bushings shall have thread lengths appli-cable to the corresponding sizes. Counterbore is optional, is notshown in Table 1, and is not included in the center-to-end orend-to-end dime
21、nsions.6.1.2 Fittings Not IllustratedAll fittings, whether illus-trated in Table 1 and Table 2 or not, shall have wall thicknessesand thread dimensions conforming to 6.1 and 6.2.6.2 ThreadsFor all fittings having taper pipe threads,threads shall conform to Specification F1498 and be gaged inaccordan
22、ce with 8.4.6.3 Burst Pressure:6.3.1 The burst strength of the fittings shall be not less thanthat calculated for the size and wall thickness of the pipe withwhich it is to be used, when calculated from the followingequation:S 5 PDOt!/2t (1)where:S = hoop stress, psi (or MPa),P = internal pressure,
23、psi (or MPa),DO= average outside diameter, in. (or mm), andt = minimum wall thickness, in. (or mm).Fittings tested in accordance with 8.4 shall withstand theminimum burst pressure shown in Table 3.6.3.2 Pressures shown are minimum burst pressures and donot imply rated working pressures. The burst pr
24、essure shall beused only as an indication of quality.7. Workmanship, Finish, and Appearance7.1 The fittings shall be homogeneous throughout and freeof cracks, holes, foreign inclusions, or other defects. TheTABLE 1 Dimensions of 90 Ells, Tees, Crosses, 45 Elbows and Couplings (Straight Sizes), in. (
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD24642013STANDARDSPECIFICATIONFORTHREADEDPOLYVINYLCHLORIDEPVCPLASTICPIPEFITTINGSSCHEDULE80 螺纹 聚氯乙烯

链接地址:http://www.mydoc123.com/p-512913.html