ASTM D512-2010 Standard Test Methods for Chloride Ion In Water《测定水中氯离子含量的标准试验方法》.pdf
《ASTM D512-2010 Standard Test Methods for Chloride Ion In Water《测定水中氯离子含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D512-2010 Standard Test Methods for Chloride Ion In Water《测定水中氯离子含量的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D512 10Standard Test Methods forChloride Ion In Water1This standard is issued under the fixed designation D512; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicat
2、es the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 These test methods cover the determination of chlorideion in water, wastewater (Te
3、st Method C only), and brines. Thefollowing three test methods are included:SectionsTest Method A (Mercurimetric Titration) 7 to14Test Method B (Silver Nitrate Titration) 15 to 21Test Method C (Ion-Selective Electrode Method) 22 to 291.2 Test MethodsA, B, and C were validated under PracticeD2777 77,
4、 and only Test Method B conforms also to PracticeD2777 86. Refer to Sections 14, 21, and 29 for furtherinformation.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafet
5、y concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For a specifichazard statement, see 26.1.1.1.5 A former colorimetric test m
6、ethod was discontinued.Refer to Appendix X1 for historical information.2. Referenced Documents2.1 ASTM Standards:2D1066 Practice for Sampling SteamD1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods
7、of Committee D19 on WaterD3370 Practices for Sampling Water from Closed ConduitsD4127 Terminology Used with Ion-Selective ElectrodesD5810 Guide for Spiking into Aqueous SamplesD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisE200 Practice for Prepa
8、ration, Standardization, and Storageof Standard and Reagent Solutions for Chemical Analysis3. Terminology3.1 DefinitionsFor definitions of terms used in these testmethods, refer to Terminologies D1129 and D4127.4. Significance and Use4.1 Chloride ion is under regulation in waste water, andmust, ther
9、efore, be measured accurately. It is highly detrimen-tal to high-pressure boiler systems and to stainless steel, somonitoring is essential for prevention of damage. Chlorideanalysis is widely used as a tool for estimating the cycles ofconcentration, such as in cooling tower applications. Process-ing
10、 waters and pickling solutions used in the food processingindustries also require dependable methods of analysis forchloride.5. Purity of Reagents5.1 Reagent grade chemicals shall be used in all tests.Unless otherwise indicated, it is intended that all reagents shallconform to the specifications of
11、the Committee on AnalyticalReagents of the American Chemical Society, where suchspecifications are available.3Other grades may be used, pro-vided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.5.2 Purity of
12、Water Unless otherwise indicated, refer-ences to water shall be understood to mean Type I reagentwater conforming to Specification D1193. Other reagent watertypes may be used provided it is first ascertained that the water1These test methods are under the jurisdiction of ASTM Committee D19 onWater a
13、nd are the direct responsibility of Subcommittee D19.05 on InorganicConstituents in Water.Current edition approved Sept. 15, 2010. Published November 2010. Originallyapproved in 1938. Last previous edition approved in 2004 as D512 04. DOI:10.1520/D0512-10.2For referenced ASTM standards, visit the AS
14、TM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. F
15、or suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmaceutical Convention, Inc. (USPC), Rockville,MD.1*A Summary of Change
16、s section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.is of sufficiently high purity to permit its use without adverselyaffecting the precision and bias of the test method. Type IIwater was spec
17、ified at the time of round robin testing of thistest method.6. Sampling6.1 Collect the sample in accordance with Practice D1066and Practices D3370, as applicable.TEST METHOD AMERCURIMETRICTITRATION47. Scope7.1 This test method can be used to determine chloride ionin water, provided interferences are
18、 absent (see Section 9).7.2 Though not specified in the research report, the preci-sion statement is presumed to have been obtained using Type IIreagent water. It is the responsibility of the analyst to assure thevalidity of this test method for untested matrices.7.3 This test method was validated f
19、or the concentrationrange 8.0 to 250 mg/L Cl.8. Summary of Test Method8.1 Dilute mercuric nitrate solution is added to an acidifiedsample in the presence of mixed diphenylcarbazone-bromophenol blue indicator.The end point of the titration is theformation of the blue-violet mercury diphenylcarbazone
20、com-plex.9. Interferences9.1 The anions and cations generally found in water offer nointerference. Zinc, lead, nickel, and ferrous and chromous ionsaffect solution and end-point colors, but do not reduce theaccuracy of the titration when present in concentrations up to100 mg/L. Copper is tolerable u
21、p to 50 mg/L. Titration in thepresence of chromate ion requires indicator with extra back-ground color (alphazurine) and prior reduction for concentra-tions above 100 mg/L. Ferric ion above 10 mg/L must bereduced before titration, and sulfite ion must be oxidized.Bromide, iodide, and fluoride will b
22、e titrated or partiallytitrated with the chloride. Quaternary ammonium salts alsointerfere if present in significant amounts (1 to 2 mg/L). Deepcolor may also interfere.10. Apparatus10.1 Microburet, 1 or 5-mL, with 0.01-mL graduationintervals.11. Reagents and MaterialsNOTE 1Consult the manufacturer
23、Material Safety Data Sheet for safework practices before working with reagents.11.1 Hydrogen Peroxide (30 % H2O2).11.2 Hydroquinone Solution (10 g/L)Dissolve1gofpurified hydroquinone in water and dilute to 100 mL.11.3 Mercuric Nitrate Solution, Standard (0.025N)Dissolve 4.2830 g of mercuric nitrate
24、(Hg(NO3)2H2O) in 50mL of water acidified with 0.5 mL of concentrated nitric acid(HNO3, sp gr 1.42). Dilute the acidified Hg(NO3)2solutionwith water to 1 L. Filter if necessary, and standardize againstthe standard sodium chloride (NaCl) solution, using the pro-cedure described in Section 12 (see Note
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD5122010STANDARDTESTMETHODSFORCHLORIDEIONINWATER 测定 水中 氯离子 含量 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-511820.html