ASTM D2220-2002(2007)e1 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable 75 &176 C Operation《工作温度75C的电线和电缆用聚氯乙烯绝缘性的标准规范》.pdf
《ASTM D2220-2002(2007)e1 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable 75 &176 C Operation《工作温度75C的电线和电缆用聚氯乙烯绝缘性的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2220-2002(2007)e1 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable 75 &176 C Operation《工作温度75C的电线和电缆用聚氯乙烯绝缘性的标准规范》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2220 02 (Reapproved 2007)e1An American National StandardStandard Specification forPoly(Vinyl Chloride) Insulation for Wire and Cable, 75 COperation1This standard is issued under the fixed designation D 2220; the number immediately following the designation indicates the year oforigina
2、l adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEThe text of 5.2, 5.4, and Note 1 of Table 2 was revised editorially Oct
3、ober 2007.1. Scope1.1 This specification covers a thermoplastic insulation ofpoly(vinyl chloride) or the copolymer of vinyl chloride andvinyl acetate.1.2 This insulation is recommended for use in power andcontrol circuits at temperatures not higher than 75 C. At athickness of 15 mils (0.38 mm), appl
4、ication is limited tovoltage ratings below 300 V, and to dry locations. At athickness of 30 mils, the application range is widened to dry orwet applications, and to a voltage rating of 600 V.1.3 Whenever two sets of values are presented, in differentunits, the values in the first set are the standar
5、d, while those inparentheses are for information only.1.4 In many instances the insulation material cannot betested unless it has been formed around a conductor or cable.Therefore, tests are done on insulated wire or cable in thisspecification solely to determine the relevant property of theinsulati
6、on material and not to test the conductor or completedcable.2. Referenced Documents2.1 ASTM Standards:2D 1711 Terminology Relating to Electrical InsulationD 2633 Test Methods for Thermoplastic Insulations andJackets for Wire and Cable3. Terminology3.1 Definitions:3.1.1 For definitions of terms used
7、in this specification, referto Terminology D 1711.3.2 Definition of Term Specific to This Standard:3.2.1 aging (act of), nexposure of materials to air or oil ata temperature and a time as specified in Table 1.4. Physical Properties4.1 The insulation shall conform to the requirements forphysical prop
8、erties prescribed in Table 1.5. Electrical Requirements5.1 Perform the ac voltage, insulation resistance, and dcvoltage tests in that order when any of these tests are required.The sequence for other testing is not specified.5.2 AC Voltage TestTest the insulated conductor at the acwithstand voltage
9、as specified in Table 2. It is acceptable toomit this test if the dc withstand voltage test described in 5.4 isperformed.5.3 Insulation Resistance:5.3.1 Insulated conductors in sizesAWG 14 (2.08 mm2) andlarger shall have an insulation resistance of at least thatcorresponding to a constant of 2000 M
10、V-1000 ft at 60 F (15.6C).1This specification is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.18 on Solid Insulations, Non-Metallic Shieldings and Coveringsfor Electrical and Telecommunication Wires
11、and Cables.Current edition approved Oct. 1, 2007. Published October 2007. Originallyapproved in 1963. Last previous edition approved in 2002 as D 2220 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMS
12、tandards volume information, refer to the standards Document Summary page onthe ASTM website.TABLE 1 Physical Properties RequirementsUnaged Requirements:Tensile strength, min, psi (MPa) 2000 (13.8)Elongation at rupture, min, % 150Aged Requirements:After air oven test at 1216 1 C for 168 h:Tubular Sp
13、ecimensup to size AWG 6 (13.3 mm2)Tensile strength, min, % of unaged value 80Elongation, min, % of unaged value 75Buffed die-cut Specimenssizes AWG 6 and largerTensile strength, min, % of unaged value 75Elongation, min, % of unaged value 50Heat shock, 121 6 1 C no cracksHeat distortion, 121 6 1 C, m
14、ax, % decrease 25Vertical flame test, after passesfive 15-s applicationsOil resistance test:After oil immersion at 706 1Cfor4h:Tubular Specimensup to size AWG 6 (13.3 mm2)Tensile strength, min, % of unaged value 85Elongation, min, % of unaged value 85Buffed die-cut Specimenssizes AWG 6 and largerTen
15、sile strength, min, % of unaged value 80Elongation, min, % of unaged value 60Cold bend test, 30 6 1 C for 1 h no cracks1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.3.2 If the temperature at the time measurement was madediffers f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD222020022007E1STANDARDSPECIFICATIONFORPOLYVINYLCHLORIDEINSULATIONFORWIREANDCABLE75176COPERATION

链接地址:http://www.mydoc123.com/p-511227.html