ASTM D1746-2009 Standard Test Method for Transparency of Plastic Sheeting《塑料薄板透明度的试验方法》.pdf
《ASTM D1746-2009 Standard Test Method for Transparency of Plastic Sheeting《塑料薄板透明度的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1746-2009 Standard Test Method for Transparency of Plastic Sheeting《塑料薄板透明度的试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1746 09Standard Test Method forTransparency of Plastic Sheeting1This standard is issued under the fixed designation D 1746; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in paren
2、theses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method covers the measurement of the trans-parency of plas
3、tic sheeting in terms of regular transmittance(Tr). Although generally applicable to any translucent ortransparent material, it is principally intended for use withnominally clear and colorless thin sheeting.1.2 The values stated in SI units are to be regarded as thestandard. The values given in par
4、entheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitat
5、ions prior to use.NOTE 1There is no similar or equivalent ISO standard.NOTE 2For additional information, see Terminology E 284 and Prac-tice E 1164.2. Referenced Documents2.1 ASTM Standards:2D 618 Practice for Conditioning Plastics for TestingD 883 Terminology Relating to PlasticsD 1003 Test Method
6、for Haze and Luminous Transmittanceof Transparent PlasticsE 284 Terminology of AppearanceE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE 1164 Practice for Obtaining Spectrometric Data forObject-Color EvaluationE 1316 Terminology for Nondestructive E
7、xaminationsE 1345 Practice for Reducing the Effect of Variability ofColor Measurement by Use of Multiple MeasurementsE 1347 Test Method for Color and Color-Difference Mea-surement by Tristimulus ColorimetryE 1348 Test Method for Transmittance and Color by Spec-trophotometry Using Hemispherical Geome
8、try3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method, referto Terminologies D 883, E 284, and E 1316.4. Significance and Use4.1 The attribute of clarity of a sheet, measured by its abilityto transmit image-forming light, correlates with its regulartransmittance. S
9、ensitivity to differences improves with de-creasing incident beam- and receptor-angle. If the angularwidth of the incident beam and of the receptor aperture (as seenfrom the specimen position) are of the order of 0.1 or less,sheeting of commercial interest have a range of transparency ofabout 10 to
10、90 % as measured by this test. Results obtained bythe use of this test method are greatly influenced by the designparameters of the instruments; for example, the resolution islargely determined by the angular width of the receptoraperture. Caution should therefore be exercised in comparingresults ob
11、tained from different instruments, especially forsamples with low regular transmittance.4.2 Regular transmittance data in accordance with this testmethod correlate with the property commonly known as“see-through,” which is rated subjectively by the effect of ahand-held specimen on an observers abili
12、ty to distinguishclearly a relatively distant target. This correlation is poor forhighly diffusing materials because of interference of scatteredlight in the visual test.5. Apparatus5.1 The apparatus shall consist of a light source, sourceaperture, lens system, specimen holder, receptor aperture,pho
13、toelectric detector, and an indicating or recording system,1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.40 on Optical Properties.Current edition approved Feb. 1, 2009. Published March 2009. Originallyapproved in 196
14、0. Last previous edition approved in 2003 as D 1746 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Su
15、mmary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.arranged to measure regular transmittance. The system shallmeet the following requirements:5.1.1 An incandescent or vapor-arc
16、 lamp, with a regulatedpower supply such that fluctuations in light intensity shall beless than 61 %. If an arc lamp is used, an appropriate filtershall be used to limit light only to the spectral range from 540to 560 nm.5.1.2 Asystem of apertures and lenses shall be used that willprovide a symmetri
17、cal incident beam. When measured with theindicating or recording system of the apparatus, using areceptor aperture having a width or diameter subtending anangle of 0.025 6 0.005 at the plane of the specimen, theincident beam shall meet the following requirements:Angle, Maximum RelativeIntensity0 100
18、0.05 100.1 10.3 0.1The source aperture may be circular or a rectangular slithaving a length-to-width ratio of at least 10.5.1.3 A holder shall be provided that will secure thespecimen so that its plane is normal to the axis of the incidentbeam at a fixed distance from the receptor aperture. Provisio
19、nmust be made for rotating the specimen if slit optics are used.Provision for transverse motion may be provided to facilitatereplication of measurements.5.1.4 An aperture shall be provided over the receptor so thatits diameter or width subtends an angle, at the plane of thespecimen, of 0.1 6 0.025.
20、The image of the source aperturewith no specimen in place shall be the same shape as thereceptor aperture centered on and entirely within it.5.1.5 A photoelectric detector shall be provided such thatthe indicated or recorded response to incident light shall besubstantially a linear function and unif
21、orm over the entirerange from the unobstructed beam (Io) to 0.01 Ioor less.5.1.6 Means shall be provided for relatively displacing thereceptor or the image of the source aperture (in the plane of thereceptor aperture) by at least 1 from the optical axis of theundeviated incident beam; for circular a
22、pertures, in two direc-tions at right angles to each other; for slit optics, in thedirection of the short dimension of the slit.NOTE 3This provision is necessary for checking the geometry of theincident beam (5.1.2) and for readjusting for maximum light intensity inthe event that the beam is deviate
23、d by a specimen with nonparallelsurfaces.NOTE 4Apparatus meeting these requirements has been described inthe literature,3and commercial versions are available.46. Reference Materials6.1 Since no regular transmittance standards are known tobe available, it is recommended that specimens of glass oroth
24、er material believed to maintain constant light transmissionproperties with time be selected that yield different regulartransmittance values for use as reference materials.6.2 Measure the regular transmittance value of each speci-men, and label it with the value obtained.6.3 Keep these reference ma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD17462009STANDARDTESTMETHODFORTRANSPARENCYOFPLASTICSHEETING 塑料 薄板 透明度 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-510394.html