ASTM C849-1988(2006) Standard Test Method for Knoop Indentation Hardness of Ceramic Whitewares《卫生陶瓷努氏压痕硬度的试验方法》.pdf
《ASTM C849-1988(2006) Standard Test Method for Knoop Indentation Hardness of Ceramic Whitewares《卫生陶瓷努氏压痕硬度的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C849-1988(2006) Standard Test Method for Knoop Indentation Hardness of Ceramic Whitewares《卫生陶瓷努氏压痕硬度的试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 849 88 (Reapproved 2006)Standard Test Method forKnoop Indentation Hardness of Ceramic Whitewares1This standard is issued under the fixed designation C 849; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the Knoopindentation hardness of ceramic whitewares and the verifica-tio
3、n of Knoop indentation hardness testing machines usingstandard glasses.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine th
4、e applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E4 Practices for Force Verification of Testing MachinesE 384 Test Method for Microindentation Hardness of Ma-terials3. Terminology3.1 Definitions:3.1.1 Knoop hardness number ( KHN)a number obtainedby d
5、ividing the applied load in kilograms-force by the pro-jected area of the indentation in square millimetres, computedfrom the measured long diagonal of the indentation and theincluded edge angles of the diamond. It is assumed that theindentation is an imprint of the undeformed indenter.4. Summary of
6、 Test Method4.1 This test method describes an indentation hardness testusing a calibrated machine to force a pointed, rhombic-base,pyramidal diamond indenter having specified face angles,under a predetermined load, into the surface of the materialunder test and to measure the long diagonal of the re
7、sultingimpression after removal of the load.NOTE 1A general description of the Knoop indentation hardness testis given in Test Method E 384. The present method differs from thisdescription only in areas required by the special nature of ceramicwhitewares.5. Significance and Use5.1 The Knoop indentat
8、ion hardness is one of many prop-erties that is used to characterize ceramic whitewares.Attemptshave been made to relate Knoop indentation hardness to tensilestrength, grinding speeds, and other hardness scales, but nogenerally accepted methods are available. Such conversionsare limited in scope and
9、 should be used with caution, except forspecial cases where a reliable basis for the conversion has beenobtained by comparison tests.6. Apparatus6.1 Testing Machines:6.1.1 There are two general types of machines available formaking this test. One type is a self-contained unit built for thispurpose,
10、and the other type is an accessory available to existingmicroscopes. Usually, this second type is fitted on an inverted-stage microscope. Good descriptions of the various machinesare available.3,46.1.2 Design of the machine should be such that the loadingrate, dwell time, and applied load can be sta
11、ndardized withinthe limits set forth in 3.1.1. It is an advantage to eliminate thehuman element whenever possible by appropriate machinedesign. The machine should be designed so that vibrationsinduced at the beginning of a test will be damped out by thetime the indenter touches the sample.6.1.3 The
12、calibration of the balance beam should be checkedmonthly or as needed. Indentations in standard glasses are alsoused to check calibration when needed.6.2 Indenter:6.2.1 The indenter shall meet the specifications for Knoopindenters.3See Test Method E 384.6.2.2 Fig. 1 shows the indenter and its maximu
13、m usabledimensions. The diagonals have an approximate ratio of 7:1,and the depth of the indentation is about130 the length of thelong diagonal. A perfect Knoop indenter has the followingangles:1This test method is under the jurisdiction ofASTM Committee C21 on CeramicWhitewares and Related Products
14、and is the direct responsibility of SubcommitteeC21.03 on Methods for Whitewares and Environmental Concerns.Current edition approved Feb. 15, 2006. Published February 2006. Originallyapproved in 1976. Last previous edition approved in 1999 as C 849 88 (1999).2For referenced ASTM standards, visit the
15、 ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Specifications for Knoop indenters can be found in Small, L., Hardness Theoryand Practice (Part I: Pr
16、actice) pp. 241243, Service Diamond Tool Co., Ann Arbor,MI, 1960.4Mott, B. W., Micro-Indentation Hardness Testing, Butterworths ScientificPublications, London, 1956.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.2.2.1 Included lon
17、gitudinal angle 172 30 min 00 s.6.2.2.2 Included transverse angle 130 00 min 00 s.6.2.3 The constant Cpfor a perfect indenter is 0.070 28, andthe specifications require a variation of not more than 1 % fromthis value.6.3 Measuring MicroscopeThe measurement system shallbe so constructed that the leng
18、th of the diagonals can bedetermined with errors not exceeding 60.0005 mm. Theapparent length of the diagonal is corrected in the calculationsfor the limit of resolution of the objective being used in themicroscope.7. Test Specimens7.1 The Knoop indentation hardness test is adaptable to awide variet
19、y of ceramic whiteware specimens. In general, theaccuracy of the test will depend on the smoothness of thesurface and, whenever possible, ground and polished speci-mens should be used. The back of the specimen shall be fixedso that the specimen cannot rock or shift during the test.7.1.1 ThicknessAs
20、long as the specimen is over ten timesas thick as the indentation depth, this will not affect the test. Ingeneral, if specimens are at least 0.10 mm thick, the hardnesswill not be affected by variations in the thickness.7.1.2 Surface FinishAs pointed out above, the accuracyof the test depends on the
21、 surface finish. However, if one isinvestigating a surface coating or treatment, he cannot grindand polish the sample. Experience has shown that six inden-tations on a ground and polished surface of glass will repro-duce within 61 %. Six indentations on an “as-received”surface may be as bad as 610 %
22、. Ground and polished surfacesshould be used. If this is not possible, the number of indenta-tions should be increased.7.1.3 Radius of CurvatureThe KHN obtained will beaffected even when the curvature is only in the direction of theshort diagonal. Care should be used when relating KHN valuesobtained
23、 on curved surfaces to those obtained on polished flatsurfaces.8. Preparation of Apparatus8.1 Verification of LoadMost of the machines availablefor Knoop hardness testing use a loaded beam. This beamshould be tested for zero load. An indentation should not bevisible with zero load, but the indenter
24、should contact thesample. A visible indentation should be obtained with a load of0.1 gf. Other methods of verifying the load application aregiven in Practice E4.8.2 Verification by Standard GlassesTable 1 gives theKnoop hardness of several National Institute of Standards andTechnology (NIST) standar
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC84919882006STANDARDTESTMETHODFORKNOOPINDENTATIONHARDNESSOFCERAMICWHITEWARES 卫生陶瓷 压痕 硬度 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-508535.html