ASTM C702-1998(2003) Standard Practice for Reducing Samples of Aggregate to Testing Size《将集料的现场试样减小到适于试验的标准实施规程》.pdf
《ASTM C702-1998(2003) Standard Practice for Reducing Samples of Aggregate to Testing Size《将集料的现场试样减小到适于试验的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C702-1998(2003) Standard Practice for Reducing Samples of Aggregate to Testing Size《将集料的现场试样减小到适于试验的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 702 98 (Reapproved 2003)American Association StateHighway and TransportationOfficials Standard: T 248Standard Practice forReducing Samples of Aggregate to Testing Size1This standard is issued under the fixed designation C 702; the number immediately following the designation indicates
2、 the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers three methods for the red
3、uction oflarge samples of aggregate to the appropriate size for testingemploying techniques that are intended to minimize variationsin measured characteristics between the test samples so se-lected and the large sample.1.2 The values stated in SI units are to be regarded as thestandard.1.3 This stan
4、dard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 A
5、STM Standards:C 125 Terminology Relating to Concrete and ConcreteAggregates2C 128 Test Method for Density, Relative Density (SpecificGravity), and Absorption of Fine Aggregate2D 75 Practice for Sampling Aggregates33. Terminology3.1 DefinitionsThe terms used in this practice are definedin Terminology
6、 C 125.4. Significance and Use4.1 Specifications for aggregates require sampling portionsof the material for testing. Other factors being equal, largersamples will tend to be more representative of the total supply.This practice provides procedures for reducing the largesample obtained in the field
7、or produced in the laboratory to aconvenient size for conducting a number of tests to describe thematerial and measure its quality in a manner that the smallertest sample portion is most likely to be a representation of thelarger sample, and thus of the total supply. Failure to carefullyfollow the p
8、rocedures in this practice could result in providinga nonrepresentative sample to be used in subsequent testing.The individual test methods provide for minimum amount ofmaterial to be tested.4.2 Under certain circumstances, reduction in size of thelarge sample prior to testing is not recommended. Su
9、bstantialdifferences between the selected test samples sometimes can-not be avoided, as for example, in the case of an aggregatehaving relatively few large size particles in the sample. Thelaws of chance dictate that these few particles may beunequally distributed among the reduced size test samples
10、.Similarly, if the test sample is being examined for certaincontaminants occurring as a few discrete fragments in onlysmall percentages, caution should be used in interpretingresults from the reduced size test sample. Chance inclusion orexclusion of only one or two particles in the selected testsamp
11、le may importantly influence interpretation of the charac-teristics of the original sample. In these cases, the entireoriginal sample should be tested.5. Selection of Method5.1 Fine AggregateReduce the size of samples of fineaggregate that are drier than the saturated-surface-dry condi-tion (Note 1)
12、 using a mechanical splitter according to MethodA. Reduce the size of samples having free moisture on theparticle surfaces by quartering according to Method B, or bytreating as a miniature stockpile as described in Method C.5.1.1 If the use of Method B or Method C is desired, and thesample does not
13、have free moisture on the particle surfaces,moisten the sample to obtain free moisture on the particlesurfaces, mix thoroughly, and then reduce the sample size.5.1.2 If use of Method A is desired and the sample has freemoisture on the particle surfaces, dry the entire sample to atleast the saturated
14、-surface-dry condition, using temperaturesthat do not exceed those specified for any of the testscontemplated, and then reduce the sample size. Alternatively, ifthe moist sample is very large, make a preliminary split usinga mechanical splitter having chute openings of 38 mm (112 in.)or more in widt
15、h to reduce the sample to not less than 5000 g.Dry the portion so obtained, and reduce it to test sample sizeusing Method A.NOTE 1The method of determining the saturated-surface-dry condi-tion is described in Test Method C 128. As a quick approximation, if the1This practice is under the jurisdiction
16、 of ASTM Committee C09 on Concreteand Concrete Aggregates and is the direct responsibility of Subcommittee C09.20 onNormal Weight Aggregates.Current edition approved May 10, 1998. Published December 1998. Originallyapproved in 1971. Last previous edition approved in 1993 as C 702 93.2Annual Book of
17、ASTM Standards, Vol 04.02.3Annual Book of ASTM Standards, Vol 04.03.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.fine aggregate will retain its shape when molded in the hand, it may beconsidered to be wetter than saturated-surface
18、-dry.5.2 Coarse Aggregates and Mixtures of Coarse and FineAggregatesReduce the sample using a mechanical splitter inaccordance with Method A (preferred method) or by quarteringin accordance with Method B. The miniature stockpile MethodC is not permitted for coarse aggregates or mixtures of coarseand
19、 fine aggregates.6. Sampling6.1 Obtain samples of aggregate in the field in accordancewith Practice D 75, or as required by individual test methods.When tests for sieve analysis only are contemplated, the size ofthe field sample listed in Practice D 75 is usually adequate.When additional tests are t
20、o be conducted, the user shall besatisfied that the initial size of the field sample is adequate toaccomplish all intended tests. Use similar procedures foraggregate produced in the laboratory.METHOD AMECHANICAL SPLITTER7. Apparatus7.1 Sample SplitterSample splitters shall have an evennumber of equa
21、l width chutes, but not less than a total of eightfor coarse aggregate, or twelve for fine aggregate, whichdischarge alternately to each side of the splitter. For coarseaggregate and mixed aggregate, the minimum width of theindividual chutes shall be approximately 50 % larger than thelargest particl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC70219982003STANDARDPRACTICEFORREDUCINGSAMPLESOFAGGREGATETOTESTINGSIZE 集料 现场 试样 减小 适于 试验 标准 实施 规程

链接地址:http://www.mydoc123.com/p-508061.html