ASTM C520-2004(2010) Standard Test Methods for Density of Granular Loose Fill Insulations《粒状疏松的填充隔热材料密度的标准试验方法》.pdf
《ASTM C520-2004(2010) Standard Test Methods for Density of Granular Loose Fill Insulations《粒状疏松的填充隔热材料密度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C520-2004(2010) Standard Test Methods for Density of Granular Loose Fill Insulations《粒状疏松的填充隔热材料密度的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C520 04 (Reapproved 2010)Standard Test Methods forDensity of Granular Loose Fill Insulations1This standard is issued under the fixed designation C520; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 These test methods are applicable to granula
3、r loose fillinsulation materials such as vermiculite and perlite. They areused for other insulation materials with similar flow andsettling properties.1.2 Method A shall be used to determine bulk density.1.3 Method B shall be used to determine design densityand, with MethodA, is used to calculate pe
4、rcent loss of volumedue to settling.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limi
5、tations prior to use.2. Referenced Documents2.1 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC390 Practice for Sampling and Acceptance of ThermalInsulation Lots3. Terminology3.1 The definitions of terms used in this method shall be inaccordance with Terminology C168.3.2 Definitions
6、 of Terms Specific to This Standard:3.2.1 bulk densitythe density of the granular material isdetermined in accordance with Method A. No conditioning isrequired unless specified. The density is determined for thematerial as received. The voids incorporated during the place-ment procedure are included
7、.3.2.2 design densitythe density of the conditioned granu-lar material, determined in accordance with Method B. Thenormal voids incorporated during the placement and subse-quent procedures are included.3.2.3 percent volume lossthe loss in volume between theas received bulk density and the design den
8、sity determined byinduced settling procedures or specified conditioning, or both,expressed as a percent.4. Significance and Use4.1 Method A will be used primarily as a manufacturingquality control and field test method without the need forconditioning. For more accurate research purposes, condition-
9、ing shall be specified.4.2 Method B will be used, when specified, to determine thedensity at which insulation properties such as thermal resis-tance and placement coverage are to be determined.5. Apparatus5.1 Bulk Density ContainerA lightweight rigid box withinterior length, width, and depth of 12.0
10、 6 0.1 in. (3.05 6 3mm). Scales or balances with an accuracy of at least1%ofthespecimen weight shall be used.5.2 Design Density Sample ContainerThe specimen con-tainer shall be made of nominal12 in. thick construction gradeplywood and two 48-in. (1220 mm) long sections of, nominal2 by 8-in. lumber.
11、The 2 by 8 sections of wood and plywoodshall be used to provide inside container dimensions of 14. 5 6 0.1 in. (368 6 3 mm) by 48 6 0.1 in. (1.22 m 6 0.003 m)by 7.5 6 0.1 in. (191 mm 6 3 mm). The inside dimensions ofthe specimen container shall be used to calculate the volume ofthe container.5.3 Scr
12、eedA suitable piece of wood, metal, or plastic atleast 20 in. (508 mm) long with a thin straight edge suitable forleveling the loose, granular material.5.4 Tapping Hammer and FrameThis shall include astandard 712-lb (3.4 kg) sledge hammer. The total length of thehandle shall be approximately 34 in.
13、(864 mm). A14-in.(6-mm) hole is drilled through the handle to provide a pivotpoint 3218 618 in. (816 mm 6 3 mm) from the center line of1These test methods are under the jurisdiction of ASTM Committee C16 onThermal Insulation and are the direct responsibility of Subcommittee C16.32 onMechanical Prope
14、rties.Current edition approved Nov. 1, 2010. Published January 2011. Originallyapproved in 1963. Last previous edition approved in 2004 as C520 04. DOI:10.1520/C0520-04R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For An
15、nual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.the head of the hammer. The tapping hammer shall be mountedin a moveable f
16、rame as shown in Fig. 1.5.5 Blowing Machine, OptionalA blowing machine, ifused, shall be typical of the type of blowing machine recom-mended by the insulation manufacturer and shall be equippedwith 100 ft. (30 m) of the type and diameter of blower hoserecommended by the insulation manufacturer for f
17、ield instal-lation.6. Sampling6.1 For the purposes of standard tests, sampling shall be inaccordance with Practice C390.7. Conditioning7.1 When specified as a requirement of testing, conditionspecimens for at least 24 h at 50 6 2 % relative humidity and73 6 2F (23 6 1.1C), and test under the specifi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC52020042010STANDARDTESTMETHODSFORDENSITYOFGRANULARLOOSEFILLINSULATIONS 粒状 疏松 填充 隔热材料 密度 标准 试验 方法

链接地址:http://www.mydoc123.com/p-466919.html