ASTM C1681-2018 Standard Test Method for Evaluating the Tear Resistance of a Sealant Under Constant Strain《评定恒定应变条件下密封剂抗扯性的标准试验方法》.pdf
《ASTM C1681-2018 Standard Test Method for Evaluating the Tear Resistance of a Sealant Under Constant Strain《评定恒定应变条件下密封剂抗扯性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1681-2018 Standard Test Method for Evaluating the Tear Resistance of a Sealant Under Constant Strain《评定恒定应变条件下密封剂抗扯性的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1681 14C1681 18Standard Test Method forEvaluating the Tear Resistance of a Sealant Under ConstantStrain1This standard is issued under the fixed designation C1681; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method evaluates the impact of an induced tear on a sealant specimen that is dimensioned, cured accord
3、ing to theguidelines in Test Method C719 and then subjected to a constant strain. It is effective in differentiating between sealants that areused in dynamic joints subject to abrasion, punctures, tears, or combination thereof.1.2 Since this test method is for the evaluation of tear propagation, an
4、adhesive failure to the substrates provides no usable dataregarding tear propagation. This would be considered a failed test and that data would be discarded, or at least separated from theother data from specimens that did not experience an adhesive failure.1.3 This standard does not purport to add
5、ress all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.1.4 The committee with jurisd
6、iction over this standard is not aware of any comparable standards published by otherorganizations.1.5 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International S
7、tandards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C717 Terminology of Building Seals and SealantsC719 Test Method for Adhesion and Cohesion of Elastomeric Joint Sealants Under Cyclic Movem
8、ent (Hockman Cycle)3. Terminology3.1 DefinitionsRefer to Terminology C717 for definitions of the following terms used in this test method: castingspacer.standard, including but not limited to the following: adhesive failure, casting spacers, cohesive failure, separators, standardconditions.3.2 separ
9、atorsrigid spacers used to maintain a constant strain on the joint specimens during the testing period whilemaintaining parallel bond surfaces.4. Summary of Test Method4.1 Test specimens are fabricated and cured in accordance with Test Method C719. At the end of the 21-day cure period, aninduced tea
10、r is created in the specimens by making a cut with a sharp blade in the midpoint of the joint. The specimens are thenextended to a specified strain at both standard conditions and at 26 6 2C (15 6 3F). Propagation of the induced tear ismeasured at 0, 24 and 168 h.1 This test method is under the juri
11、sdiction of ASTM Committee C24 on Building Seals and Sealants and is the direct responsibility of Subcommittee C24.20 on GeneralTest Methods.Current edition approved June 1, 2014Jan. 1, 2018. Published July 2014January 2018. Originally approved in 2009. Last previous edition approved in 20092014 asC
12、1681-09.-14. DOI: 10.1520/C1681-14.10.1520/C1681-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This docu
13、ment is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as
14、appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Significance and Use5.1 This test method is intended t
15、o determine if a joint that is subjected to a mechanically induced cut will resist tear propagationduring normal joint movement.Asealant with a high resistance to tear propagation will typically perform better than a sealant witha low resistance to tear propagation.6. Apparatus6.1 A device capable o
16、f extending the test specimens to the specified strain.6.2 Freezer, to maintain a constant temperature of 26C 6 2C.6.3 A suitable measuring device such as calipers able to measure the induced tears to 0.01 mm.6.4 #17 Knife Blade, 9 mm (0.37538 in.) wide.7. Reagents and Materials7.1 Spatulas, for use
17、 in applying the sealant.7.2 Caulking Gun, for extruding sealant from cartridges when applicable.7.3 Substratestwelve substrates, with minimum dimensions of 25 by 75 mm (1 by 3 in.) of the same finish are required foreach product to be tested. Glass is the default substrate, however as mentioned in
18、the scope, this is not an adhesion test, thereforethe sealant must exhibit excellent adhesion to the substrate. Other rigid substrates in the above noted dimension are acceptable.Substrate blocks or plates should be of adequate thickness or reinforced such that they do not flex or break during the t
19、esting.7.4 Casting SpacersMade from polytetrafluoroethylene (PTFE) or a suitable rigid material shall be used with each testspecimen to which the test sealant will not bond and will provide the appropriate joint dimensions and configurations. The Thecasting spacers provide joint dimensions of 12.7 b
20、y 12.7 by 50.8 mm (0.512 by 120.5 by 2 in.). See Fig. 5 in Test Method C719.7.5 Separators, to provide a constant strain on the specimen while maintaining parallel bond surfaces.7.6 Substrate Cleaning Material.7.7 Primer, if required on the substrates.7.8 A suitable measuring device, such as caliper
21、s, capable of measuring the induced cut in the sealant and additional changesin the cut to 0.01 mm.7.9 Marker, to identify the exact placement of the induced cut.7.10 A device which holds a #17 knife blade 9 mm (0.37538 in.) wide to induce the cut into the test specimens. See Fig. 1.8. Conditioning8
22、.1 Multicomponent SealantsPrepare six test specimens for each type of substrate that is to be used in the test. Aftermaintaining the unopened sample for at least 24 h at standard conditions, mix thoroughly for 5 min at least 250 g of base compoundwith the appropriate amount of curing agent. Extrude
23、the sealant 12.7 by 12.7 by 50.8 mm (0.512 by 120.5 by 2 in.) betweenFIG. 1 #17 BladeC1681 182parallel 25.4 by 76.2 mm (1 by 3 in.) surfaces of similar blocks or plates of the selected substrate. Use the appropriate castingspacer blocks spacers to form the proper size of the bead.Apply polyethylene
24、adhesive tape or any other suitable inert release agentto the inside surfaces of the spacers to prevent adhesion of the spacers to the sealant after cure. Use adhesive tape, rubber bands,or clamps to hold the test assembly together before and after filling it with the compound. In the case of a pour
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16812018STANDARDTESTMETHODFOREVALUATINGTHETEARRESISTANCEOFASEALANTUNDERCONSTANTSTRAIN 评定 恒定 应变 条件下

链接地址:http://www.mydoc123.com/p-465506.html