ASTM C1649-2014 Standard Practice for Instrumental Transmittance Measurement of Color for Flat Glass Coated and Uncoated《对有涂层和无涂层的平板玻璃的颜色进行仪器投射测量的标准实施规程》.pdf
《ASTM C1649-2014 Standard Practice for Instrumental Transmittance Measurement of Color for Flat Glass Coated and Uncoated《对有涂层和无涂层的平板玻璃的颜色进行仪器投射测量的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1649-2014 Standard Practice for Instrumental Transmittance Measurement of Color for Flat Glass Coated and Uncoated《对有涂层和无涂层的平板玻璃的颜色进行仪器投射测量的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1649 08C1649 14Standard Practice forInstrumental Transmittance Measurement of Color for FlatGlass, Coated and Uncoated1This standard is issued under the fixed designation C1649; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice provides guidelines for the instrumental transmittance measurement of the color of
3、coated and uncoatedtransparent glass. See Terminology E284.1.2 The practice specifically excludes fluorescent and iridescent samples.1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.4 This standard does not purport to ad
4、dress all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2244 Practice
5、 for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color CoordinatesE284 Terminology of AppearanceE179 Guide for Selection of Geometric Conditions for Measurement of Reflection and Transmission Properties of MaterialsE308 Practice for Computing the Colors of Obje
6、cts by Using the CIE SystemE1164 Practice for Obtaining Spectrometric Data for Object-Color EvaluationE1348 Test Method for Transmittance and Color by Spectrophotometry Using Hemispherical Geometry2.2 CIE Standard:3CIE 15:2004 Colorimetry3. Summary of Practice3.1 The color of transparent glass is me
7、asured in the total transmittance mode on a CIE-conforming diffuse instrument. (SeeGuide E179 and Test Method E1348.) The glass color is expressed in CIE tristimulus values based on spectral transmittancemeasurements over the full CIE spectral range of 350 780 nm with a maximum 10-nm band pass. (See
8、 CIE 15:2004 and PracticeE308.) For color measurement, use of a truncated spectral range of 400 700 nm is acceptable. (See CIE 15:2004.) Furtherinformation on the UVabsorbing characteristics of the glass or glass coating, or both, may be determined by examining the spectraldata in the 350 - 400 nm r
9、ange. If the instrument allows spectral measurement above 700 nm, useful information on the IRtransmittance characteristics of the glass or glass coating may also be determined. If coatings are present, they are assumed toreflect and partially transmit light.4. Significance and Use4.1 Color measurem
10、ent quantifies the transmitted color for glass. The user defines an acceptable range of color appropriate forthe end use. A typical quality concern for transmittance color measurement of glass products is verification of lot-to-lot colorconsistency for end-user acceptance.1 This practice is under th
11、e jurisdiction of ASTM Committee C14 on Glass and Glass Products and is the direct responsibility of Subcommittee C14.11 on OpticalProperties.Current edition approved Jan. 1, 2008May 1, 2014. Published January 2008May 2014. Originally approved in 2008. Last previous edition approved in 2008 as C1649
12、 08. DOI: 10.1520/C1649-08.10.1520/C1649-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from
13、U.S. National Committee of the CIE (International Commission on Illumination), C/o Thomas M. Lemons, TLA-Lighting Consultants, Inc., 7 Pond St.,Salem, MA 01970, http:/www.cie-usnc.org.CIE, Commission Internationale de LEclairage, Wien, Austria, www.cie.co.at.This document is not an ASTM standard and
14、 is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only t
15、he current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2 If the transmitted color of a glass product is consistent from lot-to-lot and within
16、agreed supplier-buyer acceptance criteria,the products color is expected to be consistent and acceptable for end-use.5. Apparatus5.1 For color measurements, a CIE-conforming diffuse sphere instrument capable of making transmission measurements in thetotal transmittance mode is required.5.2 In additi
17、on, a device for mounting the glass sample flush at the transmission port is required.5.3 The instrument and associated color quality software/firmware shall be capable of converting measured spectraltransmittance data to CIE L*, a* b*; Hunter L, a, b; orY, x, y values calculated for CIE illuminant
18、D65 and the CIE 1964 10 degreestandard observer. (See Practice E1164.)Any of those mappings will serve as a full numerical color descriptor. (See Practice E308.)CIE Y transmittance can also serve as an over-all indicator of transmission. For other illuminant/observer combinations, seePractice E308 f
19、or guidance in use. For effective communication of color values between sites, color measurements must beexpressed in the same color scale, illuminant, and standard observer.5.4 The expression of a color difference in terms of rectangular, polar, or elliptical color differences shall serve to quanti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16492014STANDARDPRACTICEFORINSTRUMENTALTRANSMITTANCEMEASUREMENTOFCOLORFORFLATGLASSCOATEDANDUNCOATED

链接地址:http://www.mydoc123.com/p-465408.html