ASTM C1610 C1610M-2010 Standard Test Method for Static Segregation of Self-Consolidating Concrete Using Column Technique《用柱技术的自密实混凝土的静态析离标准试验方法》.pdf
《ASTM C1610 C1610M-2010 Standard Test Method for Static Segregation of Self-Consolidating Concrete Using Column Technique《用柱技术的自密实混凝土的静态析离标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1610 C1610M-2010 Standard Test Method for Static Segregation of Self-Consolidating Concrete Using Column Technique《用柱技术的自密实混凝土的静态析离标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1610/C1610M 10Standard Test Method forStatic Segregation of Self-Consolidating Concrete UsingColumn Technique1This standard is issued under the fixed designation C1610/C1610M; the number immediately following the designation indicates theyear of original adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of staticsegregation of self-consolidating concrete by m
3、easuring thecoarse aggregate content in the top and bottom portions of acylindrical specimen (or column).1.2 This test method is not applicable to self-consolidatingconcrete containing lightweight aggregate.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as
4、standard. Within the text, theSI units are shown in brackets. The values stated in eachsystem may not be exact equivalents; therefore, each systemshall be used independently of the other. Combining valuesfrom the two systems may result in non-conformance with thestandard.1.4 The text of this standar
5、d references notes and footnotesthat provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.1.5 This test method is applicable under laboratory and fieldconditions.1.6 This standard does not purport to add
6、ress all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. (WarningFreshhydraulic cementitious mixtures are causti
7、c and may causechemical burns to skin and tissue upon prolonged exposure.2)2. Referenced Documents2.1 ASTM Standards:3C125 Terminology Relating to Concrete and Concrete Ag-gregatesC127 Test Method for Density, Relative Density (SpecificGravity), and Absorption of Coarse AggregateC173/C173M Test Meth
8、od for Air Content of FreshlyMixed Concrete by the Volumetric MethodC192/C192M Practice for Making and Curing ConcreteTest Specimens in the LaboratoryC231 Test Method for Air Content of Freshly Mixed Con-crete by the Pressure MethodC1712 Test Method for Rapid Assessment of Static Segre-gation Resist
9、ance of Self-Consolidating Concrete UsingPenetration TestD1785 Specification for Poly(Vinyl Chloride) (PVC) PlasticPipe, Schedules 40, 80, and 1203. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method, referto Terminology C125.3.2 Definitions of Terms Specific to This
10、Standard:3.2.1 Static Segregation, nsettlement of coarse aggregateparticles in an undisturbed mass of fresh concrete.4. Summary of Test Method4.1 Asample of freshly-mixed self-consolidating concrete isplaced in a cylindrical mold without tamping or vibration. Themold is separated into three sections
11、 representing differentlevels of the cylindrical specimen (or column). Portions ofconcrete from the top and bottom section are washed on a 4.75mm (No. 4) sieve, leaving the coarse aggregate on the sieve.The masses of coarse aggregate in the top and the bottomsections are determined and the percent s
12、tatic segregation iscalculated.5. Significance and Use5.1 This test method provides users with a procedure todetermine the potential static segregation of self-consolidatingconcrete.NOTE 1This test method may not be sufficiently rapid to evaluateself-consolidating concrete mixtures in the field befo
13、re placement. Test1This test method is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.47 onSelf-Consolidating Concrete.Current edition approved Oct. 1, 2010. Published November 2010. Originallyapproved in 2006. Last
14、 previous edition approved in 2006 as C1610/C1610M06a.DOI: 10.1520/C1610_C1610M-10.2Section on Safety Precautions, Manual of Aggregate and Concrete Testing,Annual Book of ASTM Standards, Vol. 04.02.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service
15、at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-29
16、59, United States.Method C1712 provides a rapid method for assessing static segregationresistance of self-consolidating concrete.5.2 This test method shall be used to develop self-consolidating concrete mixtures with segregation not exceed-ing specified limits. Self-consolidating concrete is a fluid
17、concrete that can be prone to segregation if not proportioned tobe cohesive. A cohesive self-consolidating concrete is impor-tant for all applications but is especially critical for deep-section applications such as walls or columns. Therefore, thedegree of segregation can indicate if a mixture is s
18、uitable forthe application.NOTE 2Some level of segregation is tolerable as long as the desiredstrength and durability performance is achieved.6. Apparatus6.1 Balanceas described in Test Method C127.6.2 Column MoldThe column portion of the mold shall bepoly(vinyl chloride) (PVC) plastic pipe Schedule
19、 40 meetingthe requirements of Specification D1785. The column shall be8 in. 200 mm in nominal diameter 3 26 in. 660 mm inheight and separated into 3 sections. The top section shall be6.5 in. 165 mm in height, the middle section 13 in. 330 mmin height, and the bottom section 6.5 in. 165 mm in height
20、, asshown in Fig. 1. Each section shall have its ends flat and planeand be marked as “Top”, “ Middle”, or “Bottom” relative to itslocation in the column. Couplers, brackets, clamps, or otherequivalent fastening systems shall be used for securing thecolumn sections together to form a mortar-tight joi
21、nt and tosecure the column to the base plate. The column mold shall besecurely attached to a non-absorbent, rigid base plate measur-ing at least 12 in. 300 mm 3 12 in. 300 mm square.NOTE 3Experience has shown that a base plate made from sealed orlaminated plywood at least 0.75 in. 20 mm thick is sui
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1610C1610M2010STANDARDTESTMETHODFORSTATICSEGREGATIONOFSELFCONSOLIDATINGCONCRETEUSINGCOLUMNTECHNIQUE

链接地址:http://www.mydoc123.com/p-465289.html