ASTM C1171-2005(2011) Standard Test Method for Quantitatively Measuring the Effect of Thermal Shock and Thermal Cycling on Refractories《耐火材料热冲击效应和热循环效应定量测量的标准试验方法》.pdf
《ASTM C1171-2005(2011) Standard Test Method for Quantitatively Measuring the Effect of Thermal Shock and Thermal Cycling on Refractories《耐火材料热冲击效应和热循环效应定量测量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1171-2005(2011) Standard Test Method for Quantitatively Measuring the Effect of Thermal Shock and Thermal Cycling on Refractories《耐火材料热冲击效应和热循环效应定量测量的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1171 05 (Reapproved 2011)Standard Test Method forQuantitatively Measuring the Effect of Thermal Shock andThermal Cycling on Refractories1This standard is issued under the fixed designation C1171; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is used for determining the strengthloss or reduction in conti
3、nuity, or both, of prism-shapedspecimens which are cut from refractory brick or shapes andsubjected to thermal cycling.1.2 The strength loss is measured by the difference inmodulus of rupture (MOR) between uncycled specimens andthe specimens subjected to thermal cycling.1.3 The reduction in structur
4、al continuity is estimated by thedifference in sonic velocity before and after thermal cycling.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered
5、 standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Re
6、ferenced Documents2.1 ASTM Standards:2C133 Test Methods for Cold Crushing Strength and Modu-lus of Rupture of RefractoriesC607 Practice for Coking Large Shapes of Carbon-BearingMaterialsC1419 Test Method for Sonic Velocity in Refractory Mate-rials at Room Temperature and Its Use in Obtaining anAppro
7、ximate Youngs ModulusE4 Practices for Force Verification of Testing MachinesE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Significance and Use3.1 This test method indicates the ability of a refractoryproduct to withstand the stress generated by su
8、dden changes intemperature.3.2 Because the recommended furnace temperature of thiscycling test is 1200C (2190F), this test method may notindicate the ability of a refractory product to withstand cyclingat higher or lower temperatures, especially if the existingmorphology of the refractory product ch
9、anges.3.3 This test method is useful for research and development,as well as for comparing refractory products. The precisionshould be considered when using this test for specificationpurposes.3.4 Ruggedness tests found the following variables to berugged:temperature +5Chot spacing12 to34 in. (12.77
10、 to 19 mm)cold spacing12 to34 in. (12.77 to 19 mm)center vs. end gripping of the barshotholdtime 10to15mincoldholdtime 10to15minoperator air speed 0 to 2 mi/h (0 to 3.2 km/h)initially cold or heated sampleslast in, first out (LIFO); or first in, first out (FIFO)removal from the furnacesawed or origi
11、nal surface as tensile face during MOR testingbar thickness 0.96 to 1.04 in. (24.5 to 26.4 mm)4. Apparatus4.1 Furnace, capable of maintaining 1200C (2190F) withrecovery rate of less than 5 min to temperature.4.2 Abrasive Saw, to cut the test specimens.1This test method is under the jurisdiction of A
12、STM Committee C08 onRefractories and is the direct responsibility of Subcommittee C08.02 on ThermalProperties.Current edition approved March 1, 2011. Published May 2011. Originallyapproved in 1991 as C1171 91. Last previous edition approved in 2005 asC1171 05. DOI: 10.1520/C1171-05R11.2For reference
13、d ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Con
14、shohocken, PA 19428-2959, United States.4.3 Dryer, capable of operating at 105C to 110C (220F to230F).4.4 Tongs or Fork, for handling hot specimens.4.5 Safety Equipment, such as gloves, face shields, andtinted safety glasses.4.6 Alumina Setter Brick, 90 %, placed 5 in. (127 mm) apartin and outside t
15、he furnace.4.7 Strength Testing MachineAny form of standard me-chanical or hydraulic compression testing machine that con-forms to the requirements of Practices E4 may be used.4.8 Sonic Velocity MachineTest apparatus3conforming tothe section on Test Apparatus of Test Method C1419.5. Sampling5.1 The
16、sampling shall consist of at least two bricks orshapes, or test samples made from monolithic refractories. Atleast ten test specimens shall be used. An equal number ofspecimens shall be taken from each of the bricks or shapes.5.2 Samples should be prefired to a temperature at least ashigh as the tes
17、t temperatures.6. Test Specimens6.1 Test specimens shall be 1 6132 in. by 1 6132 in. byapproximately 6 in. (25 6 0.8 by 25 6 0.8 by approximately152 mm). Note in the report if other specimen sizes are used.Specimens cut from brick shall have at least one original bricksurface. If cut shapes, the spe
18、cimens shall be taken parallel tothe longest dimension. For irregular shapes, all four longsurfaces of the specimens may be cut faces. Note this in thereport.6.2 Opposite faces of the specimen shall be approximatelyparallel, and adjacent faces shall be approximately perpendicu-lar.6.3 Measure the wi
19、dth and depth of the test specimen atmid-span to the nearest 0.01 in. (0.3 mm).6.4 Specimens should be visually crack- and flaw-free.6.5 Dry specimens to constant weight at 105 to 110C (220to 230F).6.6 Carbon-containing samples must be coked according toPractice C607 and must be wrapped in foil4duri
20、ng the cyclingprocedure. See Fig. 1 for the wrapping technique.7. Procedure7.1 Measure the sonic velocity along the length of each testspecimen according to Test Method C1419 and divide thespecimens into two equal groups on the basis of similardistributions of velocity measurements.7.2 Determine the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC117120052011STANDARDTESTMETHODFORQUANTITATIVELYMEASURINGTHEEFFECTOFTHERMALSHOCKANDTHERMALCYCLINGONREFRACTORIES

链接地址:http://www.mydoc123.com/p-463611.html