ASTM C1109-2010(2015) Standard Practice for Analysis of Aqueous Leachates from Nuclear Waste Materials Using Inductively Coupled Plasma-Atomic Emission Spectroscopy《采用电感耦合等离子体原子发射光.pdf
《ASTM C1109-2010(2015) Standard Practice for Analysis of Aqueous Leachates from Nuclear Waste Materials Using Inductively Coupled Plasma-Atomic Emission Spectroscopy《采用电感耦合等离子体原子发射光.pdf》由会员分享,可在线阅读,更多相关《ASTM C1109-2010(2015) Standard Practice for Analysis of Aqueous Leachates from Nuclear Waste Materials Using Inductively Coupled Plasma-Atomic Emission Spectroscopy《采用电感耦合等离子体原子发射光.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1109 10 (Reapproved 2015)Standard Practice forAnalysis of Aqueous Leachates from Nuclear WasteMaterials Using Inductively Coupled Plasma-AtomicEmission Spectroscopy1This standard is issued under the fixed designation C1109; the number immediately following the designation indicates the
2、 year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice is applicable to the determination of
3、 lowconcentration and trace elements in aqueous leachate solutionsproduced by the leaching of nuclear waste materials, usinginductively coupled plasma-atomic emission spectroscopy(ICP-AES).1.2 The nuclear waste material may be a simulated (non-radioactive) solid waste form or an actual solid radioac
4、tivewaste material.1.3 The leachate may be deionized water or any natural orsimulated leachate solution containing less than 1 % totaldissolved solids.1.4 This practice should be used by analysts experienced inthe use of ICP-AES, the interpretation of spectral and non-spectral interferences, and pro
5、cedures for their correction.1.5 No detailed operating instructions are provided becauseof differences among various makes and models of suitableICP-AES instruments. Instead, the analyst shall follow theinstructions provided by the manufacturer of the particularinstrument. This test method does not
6、address comparativeaccuracy of different devices or the precision between instru-ments of the same make and model.1.6 This practice contains notes that are explanatory and arenot part of the mandatory requirements of the method.1.7 The values stated in SI units are to be regarded as thestandard.1.8
7、This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Docum
8、ents2.1 ASTM Standards:2C859 Terminology Relating to Nuclear MaterialsC1009 Guide for Establishing and Maintaining a QualityAssurance Program forAnalytical Laboratories Within theNuclear IndustryC1220 Test Method for Static Leaching of Monolithic WasteForms for Disposal of Radioactive WasteD1193 Spe
9、cification for Reagent WaterD7035 Test Method for Determination of Metals and Met-alloids in Airborne Particulate Matter by InductivelyCoupled Plasma Atomic Emission Spectrometry (ICP-AES)E135 Terminology Relating to Analytical Chemistry forMetals, Ores, and Related MaterialsE177 Practice for Use of
10、 the Terms Precision and Bias inASTM Test Methods2.2 ISO and European Standards:3ISO 1042 Laboratory GlasswareOne-mark VolumetricFlasksISO 3585 Borosilicate Glass 3.3PropertiesISO 8655 Piston-Operated Volumetric Instruments (6 parts)3. Terminology3.1 For definitions of pertinent terms not listed her
11、e, seeTerminology C859.3.2 Definitions:3.2.1 atomic emissioncharacteristic radiation emitted byan electronically excited atomic species. D70353.2.1.1 DiscussionIn atomic (or optical) emissionspectrometry, a very high-temperature environment, such as aplasma, is used to create excited state atoms. Fo
12、r analyticalpurposes, characteristic emission signals from elements in theirexcited states are then measured at specific wavelengths.1This practice is under the jurisdiction of ASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.05 on Methods ofTest.Current e
13、dition approved June 1, 2015. Published June 2015. Originallyapproved in 1988. Last previous edition approved in 2010 as C1109 10. DOI:10.1520/C1109-10R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM
14、Standards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoho
15、cken, PA 19428-2959. United States13.2.2 background correctionprocess of correcting the in-tensity at an analytical wavelength for the intensity due to theunderlying spectral background of a blank. D70353.2.2.1 DiscussionDuring sample analysis, measurementsare made of the background intensity near t
16、he peak wavelengthof the analytical lines. Correction of the analytical line peakintensity to yield the net line intensity can be made bysubtraction of either (a) a single intensity measurement per-formed on the high or low wavelength side of the analyticalline (single-point background correction),
17、or (b) an interpo-lated background intensity from background measurementsacquired on both the high and low wavelength sides of theanalytical line (double-point background correction).3.2.3 biasbetween the expectation of the test results andan accepted reference value. E1773.2.4 calibrationthe proces
18、s by which the relationshipbetween net signal intensity and elemental concentration isdetermined for a specific element analysis.3.2.5 calibration blank solutioncalibration solution pre-pared without the addition of any reference solutions. D70353.2.6 calibration curveplot of net signal intensity ve
19、rsuselemental concentration using data obtained during calibration.3.2.7 calibration reference solution(s)solutions contain-ing known concentrations of one or more elements in 1 % (v/v)nitric acid for instrument calibration.3.2.8 critical limit (LC)minimum significant value of anestimated net signal
20、 or concentration, applied as a discrimina-tor against background noise. (1)3.2.9 inductively coupled plasma (ICP)a high-temperature discharge generated by a flowing conductive gas,normally argon, through a magnetic field induced by a load coilthat surrounds the tubes carrying the gas. D70353.2.10 i
21、nstrument check solution(s)solution(s) containingall the elements to be determined at concentration levelsapproximating the concentrations in the samples. These solu-tions must also contain 1 % (v/v) nitric acid.3.2.11 interelement correctiona spectral interference cor-rection technique in which emi
22、ssion contributions from inter-fering elements that emit radiation at the analyte wavelengthare subtracted from the apparent analyte emission after mea-suring the interfering element concentrations at otherwavelengths. D70353.2.12 limit of detection (LD)value for which the falsenegative error is B u
23、sing a given critical limit. (1)3.2.12.1 DiscussionIf the analytical standard deviation isconstant with respect to concentration, this can be computed as3.7 times the standard deviation of the analytical results fromten matrix blank samples spiked at approximately the antici-pated detection limit; o
24、therwise, see references (1, 2)4foradditional guidance.3.2.13 linear dynamic rangethe elemental concentrationrange over which the calibration curve remains linear to withinthe precision of the analytical method.3.2.14 linearity check solution(s)solution(s) containingthe elements to be determined at
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC110920102015STANDARDPRACTICEFORANALYSISOFAQUEOUSLEACHATESFROMNUCLEARWASTEMATERIALSUSINGINDUCTIVELYCOUPLEDPLASMAATOMICEMISSIONSPECTROSCOPY

链接地址:http://www.mydoc123.com/p-463413.html