ASTM C1064 C1064M-2012 Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete《新拌水硬水泥混凝土温度的标准试验方法》.pdf
《ASTM C1064 C1064M-2012 Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete《新拌水硬水泥混凝土温度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1064 C1064M-2012 Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete《新拌水硬水泥混凝土温度的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1064/C1064M 11 C1064/C1064M 12Standard Test Method forTemperature of Freshly Mixed Hydraulic-Cement Concrete1This standard is issued under the fixed designation C1064/C1064M; the number immediately following the designation indicates theyear of original adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method c
3、overs the determination of temperature of freshly mixed hydraulic-cement concrete.1.2 The values stated in either SI or inch-pound units are to be regarded separately as standard. The values stated in each systemmay not be exact equivalents; therefore, each system shall be used independently of the
4、other. Combining values from the twosystems may result in non-conformance with the standard.1.3 The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes(excluding those in tables and figures) shall not be considered as requirements of t
5、his standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. (Wa
6、rningFresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin andtissue upon prolonged exposure.2)2. Referenced Documents2.1 ASTM Standards:3C172 Practice for Sampling Freshly Mixed ConcreteC670 Practice for Preparing Precision and Bias Statements for Test Methods for C
7、onstruction Materials3. Significance and Use3.1 This test method provides a means for measuring the temperature of freshly mixed concrete. The measured temperaturerepresents the temperature at the time of testing and may not be an indication of the temperature of the freshly mixed concrete ata later
8、 time. It may be used to verify conformance to a specified requirement for temperature of concrete.3.2 Concrete containing aggregate of a nominal maximum size greater than 75 mm 3 in. may require up to 20 min for thetransfer of heat from aggregate to mortar. (See ACI Committee 207.1R Report.4)4. App
9、aratus4.1 Container, shall be large enough to provide at least 75 mm 3 in. of concrete in all directions around the sensor of thetemperature measuring device; concrete cover must also be at least three times the nominal maximum size of the coarse aggregate.4.2 Temperature Measuring Device, shall be
10、capable of accurately measuring the temperature of the freshly mixed concrete to6 0.5 C 61 F throughout a range of 0 to 50 C 30 to 120 F. The design of the temperature measuring device shall be suchthat it allows 75 mm 3 in. or more immersion during operation.4.3 Partial immersion liquid-in-glass th
11、ermometers (and possibly other types) shall have a permanent mark to which the devicemust be immersed without applying a correction factor.1 This test method is under the jurisdiction of ASTM Committee C09 on Concrete and Concrete Aggregatesand is the direct responsibility of Subcommittee C09.60 onT
12、esting Fresh Concrete.Current edition approved Dec. 1, 2011Dec. 1, 2012. Published January 2012January 2013. Originally approved in 1986. Last previous edition approved in 20082011 asC106408.11. DOI: 10.1520/C1064_C1064M-11.10.1520/C1064_C1064M-12.2 Section on Safety Precautions, Manual of Aggregate
13、 and Concrete Testing, Annual Book of ASTM Standards, Vol 04.02.3 For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM we
14、bsite.4 Available from American Concrete Institute (ACI), P.O. Box 9094, Farmington Hills, MI 48333-9094, http:/www.concrete.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Be
15、causeit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section app
16、ears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.4 Reference Temperature Measuring Device, shall be readable and accurate to 6 0.2 C 0.5 F at the verification points in5.1. A certificate or report that
17、 verifies the accuracy shall be available in the laboratory for review. Accuracy of liquid-in-glassreference temperature measuring devices shall be verified once. Verification of direct-reading resistance reference temperaturemeasuring devices shall be performed every twelve months. The certificate
18、or report shall provide documentation that the referencestandard used in the verification is traceable to the National Institute of Standards and Technology (NIST).5. Verification of the Accuracy of Temperature Measuring Devices5.1 The accuracy of each temperature measuring device used for determini
19、ng the temperature of freshly mixed concrete shallbe verified annually, or whenever there is a question of accuracy. Verify the accuracy of the temperature measuring device bycomparing the readings of the reference temperature measuring device to the temperature measuring device at two temperaturesa
20、t least 15 C 30 F apart.5.2 Verification of the accuracy of the temperature measuring devices may be made in oil or other suitable bath liquids havinguniform density if provision is made to:5.2.1 Maintain the bath temperature constant within 0.2 C 0.5 F during the verification process.5.2.2 Continuo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1064C1064M2012STANDARDTESTMETHODFORTEMPERATUREOFFRESHLYMIXEDHYDRAULICCEMENTCONCRETE 新拌水硬 水泥 混凝土

链接地址:http://www.mydoc123.com/p-463213.html