1、Designation: C 1064/C 1064M 08Standard Test Method forTemperature of Freshly Mixed Hydraulic-Cement Concrete1This standard is issued under the fixed designation C 1064/C 1064M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method covers the de
3、termination of tempera-ture of freshly mixed hydraulic-cement concrete.1.2 The values stated in either SI or inch-pound units are tobe regarded separately as standard. Within the text, SI units areshown in brackets. The values stated in each system may not beexact equivalents; therefore, each system
4、 shall be used inde-pendently of the other. Combining values from the two systemsmay result in non-conformance with the standard.1.3 The text of this standard references notes and footnotesthat provide explanatory information. These notes and foot-notes (excluding those in tables and figures) shall
5、not beconsidered as requirements of this standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of r
6、egulatory limitations prior to use. (WarningFreshhydraulic cementitious mixtures are caustic and may causechemical burns to skin and tissue upon prolonged exposure.2)2. Referenced Documents2.1 ASTM Standards:3C 172 Practice for Sampling Freshly Mixed ConcreteC 670 Practice for Preparing Precision an
7、d Bias Statementsfor Test Methods for Construction Materials3. Significance and Use3.1 This test method provides a means for measuring thetemperature of freshly mixed concrete. The measured tempera-ture represents the temperature at the time of testing and maynot be an indication of the temperature
8、of the freshly mixedconcrete at a later time. It may be used to verify conformanceto a specified requirement for temperature of concrete.3.2 Concrete containing aggregate of a nominal maximumsize greater than 3 in. 75 mm may require up to 20 min for thetransfer of heat from aggregate to mortar. (See
9、 ACI Committee207.1R Report.4)4. Apparatus4.1 Container, shall be large enough to provide at least 3 in.75 mm of concrete in all directions around the sensor of thetemperature measuring device; concrete cover must also be atleast three times the nominal maximum size of the coarseaggregate.4.2 Temper
10、ature Measuring Device, shall be capable ofaccurately measuring the temperature of the freshly mixedconcrete to 61F6 0.5 C throughout a range of 30 to 120F 0 to 50 C. The design of the temperature measuringdevice shall be such that it allows 3 in. 75 mm or moreimmersion during operation.4.3 Partial
11、immersion liquid-in-glass thermometers (andpossibly other types) shall have a permanent mark to which thedevice must be immersed without applying a correction factor.4.4 Reference Temperature Measuring Device, shall bereadable and accurate to 6 0.5 F 0.2 C at the verificationpoints in 5.1. A certifi
12、cate or report that verifies the accuracyshall be available in the laboratory for review. Accuracy ofliquid-in-glass reference temperature measuring devices shallbe verified once. Verification of direct-reading resistance ref-erence temperature measuring devices shall be performedevery twelve months
13、. The certificate or report shall providedocumentation that the reference standard used in the verifi-cation is traceable to the National Institute of Standards andTechnology (NIST).5. Calibration of Temperature Measuring Device5.1 Each temperature measuring device used for determin-ing temperature
14、of freshly mixed concrete shall be calibrated1This test method is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.60 on Testing Fresh Concrete.Current edition approved July 1, 2008. Published August 2008. Originallya
15、pproved in 1986. Last previous edition approved in 2005 as C 1064 05.2Section on Safety Precautions, Manual of Aggregate and Concrete Testing,Annual Book of ASTM Standards, Vol 04.02.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.
16、org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from American Concrete Institute (ACI), P.O. Box 9094, FarmingtonHills, MI 48333-9094, http:/www.concrete.org.1*A Summary of Changes section appears at the end of this
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1064C1064M2008STANDARDTESTMETHODFORTEMPERATUREOFFRESHLYMIXEDHYDRAULICCEMENTCONCRETE 新拌水硬 水泥 混凝土

链接地址:http://www.mydoc123.com/p-463211.html