ASTM C1017 C1017M-2013e1 Standard Specification for Chemical Admixtures for Use in Producing Flowing Concrete《流动混凝土生产用化学混合物的标准规格》.pdf
《ASTM C1017 C1017M-2013e1 Standard Specification for Chemical Admixtures for Use in Producing Flowing Concrete《流动混凝土生产用化学混合物的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1017 C1017M-2013e1 Standard Specification for Chemical Admixtures for Use in Producing Flowing Concrete《流动混凝土生产用化学混合物的标准规格》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1017/C1017M 131Standard Specification forChemical Admixtures for Use in Producing FlowingConcrete1This standard is issued under the fixed designation C1017/C1017M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1NOTECorrected editorially in May 201
3、5.1. Scope*1.1 This specification covers two types of chemical admix-tures to be added to hydraulic cement concrete mixtures for thepurpose of producing flowing concrete. The types are asfollows:1.1.1 Type IPlasticizing, and1.1.2 Type IIPlasticizing and retarding.1.2 This specification stipulates te
4、sts of a chemical admix-ture with reference concreting materials or with concrete-making materials proposed for specific work. Unless otherwisespecified by the purchaser, the tests shall be made usingreference concreting materials.1.3 If a chemical admixture has been tested and found tocomply with t
5、he provisions of this specification using referencematerials, and is being considered for use with other materialsfor specific work, additional tests for such use are allowed ifagreed upon between the purchaser and the supplier and areallowed to consist of a portion of the tests described herein.1.4
6、 This specification provides for three levels of testing.1.4.1 Level 1During the initial approval stage, proof ofcompliance with the performance requirements defined inTable 1 demonstrates that the admixture meets the require-ments of this specification. Uniformity and equivalence tests ofthe sectio
7、n on Lot Uniformity and Equivalence shall be carriedout to provide results against which later comparisons can bemade.1.4.2 Level 2Limited retesting described in the sectionrelating to general requirements may be requested at intervalsby the purchaser. Proof of compliance with the requirements ofTab
8、le 1 demonstrates continued conformity of the admixturewith the requirements of the specification.1.4.3 Level 3For acceptance of a lot or for measuringuniformity within or between lots, when specified by thepurchaser, the uniformity and equivalence tests of the sectionon Lot Uniformity and Equivalen
9、ce shall be used.1.5 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non
10、-conformancewith the standard. Some values have only SI units because theinch-pound equivalents are not used in practice.NOTE 1Sieve size is identified by its standard designation in Speci-fication E11. The alternative designation given in parentheses is forinformation only and does not represent a
11、different standard sieve size.NOTE 2It is recommended that, whenever practicable, tests be madeusing the concrete-making materials (cement, pozzolan, slag, aggregates,air-entraining admixture), the mixture proportions, and the batchingsequence and other physical conditions proposed for the specific
12、work.The specific effects produced by chemical admixtures may vary with theproperties and proportions of the other ingredients of the concrete.NOTE 3Temperature has a pronounced effect on time of setting ofconcrete. This may be exaggerated by the use of admixture Types I and II.If concrete temperatu
13、res to be expected on a particular job differsignificantly from the conditions set forth in this specification, furthertesting may be desirable.NOTE 4An unusually rapid loss of workability with time, sometimestermed “slump loss”, can be experienced with these admixtures. The rateof slump loss will v
14、ary with the particular concreting materials andproportions, mixing equipment and procedures, and temperatures experi-enced on any particular job. At elevated temperatures, the slump may beretained for a longer period if a Type II admixture is used.NOTE 5Admixtures that contain relatively large amou
15、nts of chloridemay accelerate corrosion of prestressing steel. Compliance with therequirements of this specification does not constitute assurance of accept-ability of the admixture for use in prestressed concrete (see ACI 318).NOTE 6Admixtures that contain relatively large amounts of alkali(Na2O +
16、0.658 K2O) may contribute to reaction with some aggregates.Compliance with the requirements of this specification does not assureacceptability when used with alkali-reactive aggregates and some ce-ments.1.6 The text of this standard references notes and footnoteswhich provide explanatory material. T
17、hese notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.1This specification is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.23 on Chemical Admixtures.
18、Current edition approved Dec. 15, 2013. Published February 2014. Originallyapproved in 1985. Last previous edition approved in 2007 as C1017/C1017M 07.DOI: 10.1520/C1017_C1017M-13.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO
19、 Box C700, West Conshohocken, PA 19428-2959. United States11.7 The following precautionary caveat pertains only to thetest method sections of this specification: This standard doesnot purport to address all of the safety concerns, if any,associated with its use. It is the responsibility of the user
20、of thisstandard to establish appropriate safety and health practicesand determine the applicability of regulatory limitations priorto use.WarningFresh hydraulic cementitious mixtures arecaustic and may cause chemical burns to skin and tissue uponprolonged exposure.22. Referenced Documents2.1 ASTM St
21、andards:3C33/C33M Specification for Concrete AggregatesC39/C39M Test Method for Compressive Strength of Cylin-drical Concrete SpecimensC78/C78M Test Method for Flexural Strength of Concrete(Using Simple Beam with Third-Point Loading)C125 Terminology Relating to Concrete and Concrete Ag-gregatesC136
22、Test Method for Sieve Analysis of Fine and CoarseAggregatesC138/C138M Test Method for Density (Unit Weight), Yield,and Air Content (Gravimetric) of ConcreteC143/C143M Test Method for Slump of Hydraulic-CementConcreteC150/C150M Specification for Portland CementC157/C157M Test Method for Length Change
23、 of HardenedHydraulic-Cement Mortar and ConcreteC173/C173M Test Method forAir Content of Freshly MixedConcrete by the Volumetric MethodC183 Practice for Sampling and the Amount of Testing ofHydraulic CementC192/C192M Practice for Making and Curing Concrete TestSpecimens in the LaboratoryC231/C231M T
24、est Method forAir Content of Freshly MixedConcrete by the Pressure MethodC260/C260M Specification for Air-Entraining Admixturesfor ConcreteC403/C403M Test Method for Time of Setting of ConcreteMixtures by Penetration ResistanceC666/C666M Test Method for Resistance of Concrete toRapid Freezing and Th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1017C1017M2013E1STANDARDSPECIFICATIONFORCHEMICALADMIXTURESFORUSEINPRODUCINGFLOWINGCONCRETE 流动 混凝土

链接地址:http://www.mydoc123.com/p-463067.html