ASTM C1017 C1017M-2007 Standard Specification for Chemical Admixtures for Use in Producing Flowing Concrete《流动混凝土生产用化学混合物的标准规范》.pdf
《ASTM C1017 C1017M-2007 Standard Specification for Chemical Admixtures for Use in Producing Flowing Concrete《流动混凝土生产用化学混合物的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1017 C1017M-2007 Standard Specification for Chemical Admixtures for Use in Producing Flowing Concrete《流动混凝土生产用化学混合物的标准规范》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1017/C 1017M 07Standard Specification forChemical Admixtures for Use in Producing FlowingConcrete1This standard is issued under the fixed designation C 1017/C 1017M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This specification covers
3、 two types of chemical admix-tures to be added to hydraulic cement concrete mixtures for thepurpose of producing flowing concrete. The types are asfollows:1.1.1 Type IPlasticizing, and1.1.2 Type IIPlasticizing and retarding.1.2 This specification stipulates tests of a chemical admix-ture with refere
4、nce concreting materials or with concrete-making materials proposed for specific work. Unless otherwisespecified by the purchaser, the tests shall be made usingreference concreting materials.1.3 If a chemical admixture has been tested and found tocomply with the provisions of this specification usin
5、g referencematerials, and is being considered for use with other materialsfor specific work, additional tests for such use are allowed ifagreed upon between the purchaser and the supplier and areallowed to consist of a portion of the tests described herein.1.4 This specification provides for three l
6、evels of testing.1.4.1 Level 1During the initial approval stage, proof ofcompliance with the performance requirements defined inTable 1 demonstrates that the admixture meets the require-ments of this specification. Uniformity and equivalence tests ofthe section on Lot Uniformity and Equivalence shal
7、l be carriedout to provide results against which later comparisons can bemade.1.4.2 Level 2Limited retesting described in the sectionrelating to general requirements may be requested at intervalsby the purchaser. Proof of compliance with the requirements ofTable 1 demonstrates continued conformity o
8、f the admixturewith the requirements of the specification.1.4.3 Level 3For acceptance of a lot or for measuringuniformity within or between lots, when specified by thepurchaser, the uniformity and equivalence tests of the sectionon Lot Uniformity and Equivalence shall be used.1.5 The values stated i
9、n SI units are to be regarded asstandard. The values in inch-pound units shown in parenthesesare provided for information purposes only.NOTE 1It is recommended that, whenever practicable, tests be madeusing the concrete-making materials (cement, pozzolan, slag, aggregates,air-entraining admixture),
10、the mixture proportions, and the batchingsequence and other physical conditions proposed for the specific work.The specific effects produced by chemical admixtures may vary with theproperties and proportions of the other ingredients of the concrete.NOTE 2Temperature has a pronounced effect on time o
11、f setting ofconcrete. This may be exaggerated by the use of admixture Types I and II.If concrete temperatures to be expected on a particular job differsignificantly from the conditions set forth in this specification, furthertesting may be desirable.NOTE 3An unusually rapid loss of workability with
12、time, sometimestermed “slump loss”, can be experienced with these admixtures. The rateof slump loss will vary with the particular concreting materials andproportions, mixing equipment and procedures, and temperatures experi-enced on any particular job. At elevated temperatures, the slump may beretai
13、ned for a longer period if a Type II admixture is used.NOTE 4Admixtures that contain relatively large amounts of chloridemay accelerate corrosion of prestressing steel. Compliance with therequirements of this specification does not constitute assurance of accept-ability of the admixture for use in p
14、restressed concrete (see ACI 318).NOTE 5Admixtures that contain relatively large amounts of alkali(Na2O + 0.658 K2O) may contribute to reaction with some aggregates.Compliance with the requirements of this specification does not assureacceptability when used with alkali-reactive aggregates and some
15、ce-ments.1.6 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.1.7 The following precautionary caveat pertains only to thetest method sect
16、ions of this specification: This standard doesnot purport to address all of the safety concerns, if any,1This specification is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.23 on Chemical Admixtures.Current edition
17、 approved June 1, 2007. Published July 2007. Originally approvedin 1985. Last previous edition approved in 2003 as C 1017/C 1017M 03.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
18、United States.associated with its use. It is the responsibility of the user of thisstandard to establish appropriate safety and health practicesand determine the applicability of regulatory limitations priorto use.2. Referenced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC
19、39/C 39M Test Method for Compressive Strength of Cy-lindrical Concrete SpecimensC78 Test Method for Flexural Strength of Concrete (UsingSimple Beam with Third-Point Loading)C 136 Test Method for Sieve Analysis of Fine and CoarseAggregatesC 138/C 138M Test Method for Density (Unit Weight),Yield, and
20、Air Content (Gravimetric) of ConcreteC 143/C 143M Test Method for Slump of Hydraulic-Cement ConcreteC 150 Specification for Portland CementC 157/C 157M Test Method for Length Change of Hard-ened Hydraulic-Cement Mortar and ConcreteC 173/C 173M Test Method for Air Content of FreshlyMixed Concrete by
21、the Volumetric MethodC 183 Practice for Sampling and the Amount of Testing ofHydraulic CementC 192/C 192M Practice for Making and Curing ConcreteTest Specimens in the LaboratoryC 231 Test Method for Air Content of Freshly MixedConcrete by the Pressure MethodC 260 Specification forAir-EntrainingAdmix
22、tures for Con-creteC 403/C 403M Test Method for Time of Setting of ConcreteMixtures by Penetration ResistanceC 666/C 666M Test Method for Resistance of Concrete toRapid Freezing and ThawingC 778 Specification for Standard SandD 75 Practice for Sampling AggregatesD 1193 Specification for Reagent Wate
23、rE 100 Specification for ASTM HydrometersManual of Aggregate and Concrete Testing2.2 American Concrete Institute Standard:3ACI 211.1-81 Recommended Practice for Selecting Propor-tions for Normal and Heavyweight ConcreteACI 318-83 Building Code Requirements for ReinforcedConcrete3. Terminology3.1 Def
24、initions of Terms Specific to This Standard:3.1.1 flowing concreteconcrete that is characterized by aslump greater than 712 in. (190 mm) while maintaining acohesive nature, and which otherwise meets the requirementsof Table 1.3.1.2 plasticizing admixture a chemical admixture which,when added to conc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1017C1017M2007STANDARDSPECIFICATIONFORCHEMICALADMIXTURESFORUSEINPRODUCINGFLOWINGCONCRETE 流动 混凝土

链接地址:http://www.mydoc123.com/p-463065.html