《AS NZS 3823 2-2009 Performance of electrical appliances - Air conditioners and heat pumps - Energy labelling and minimum energy performance standard (MEPS) requirements《电器的性能 空气调节器.pdf》由会员分享,可在线阅读,更多相关《AS NZS 3823 2-2009 Performance of electrical appliances - Air conditioners and heat pumps - Energy labelling and minimum energy performance standard (MEPS) requirements《电器的性能 空气调节器.pdf(89页珍藏版)》请在麦多课文档分享上搜索。
1、 AS/NZS 3823.2:2009 Australian/New Zealand StandardPerformance of electrical appliancesAir conditioners and heat pumps Part 2: Energy labelling and minimum energy performance standard (MEPS) requirements AS/NZS 3823.2:2009Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 15 Oct 2009AS
2、/NZS 3823.2:2009 This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee EL-015, Quality and Performance of Household Electrical Appliances. It was approved on behalf of the Council of Standards Australia on 24 August 2009 and on behalf of the Council of Standards New Ze
3、aland on 4 September 2009. This Standard was published on 6 October 2009. The following are represented on Committee EL-015: Airconditioning and (ii) not on display for sale through retail outlets; and (iii) not promoted in any catalogue or advertising material that could be interpreted as suitable
4、for some residential applications. (g) Air conditioners powered by mains electricity specifically designed and sold only for installation in end-use mobile applications of caravans, mobile homes, camper vans and rail cars. (h) Models that have been granted exemption by the relevant Australian/New Ze
5、aland regulatory authority due to their specific design for application such as process heating or cooling, or for heating or cooling of spaces to conditions that are not intended for human comfort. 1.3 APPLICATION This Standard shall be read in conjunction with AS/NZS 3823.1.1, AS/NZS 3823.1.2, AS/
6、NZS 3823.1.3 and AS/NZS 3823.3, as applicable. Products with water-cooled condensers as well as water-source heat pumps fall within the scope of this Standard and shall meet the relevant labelling and/or MEPS requirements for the cooling and/or heating function. For these products, the cooling and h
7、eating performance shall be determined and declared in accordance with AS/NZS 3823.1.3. Cooling only products with water-cooled condensers that are included within the scope of AS/NZS 3823.1.1 and AS/NZS 3823.1.2 shall be tested to AS/NZS 3823.1.3 wherever possible. 1.4 OBJECTIVE The objective of th
8、is Standard is to (a) provide detailed information on the performance and energy labelling requirements that an air conditioning appliance has to meet in order to carry a valid energy efficiency label; (b) provide detailed information on the performance requirements that an air conditioning applianc
9、e has to meet in order comply with minimum energy performance standard requirements; and (c) describe the circumstances in which alternatives to physical testing may be used to demonstrate and verify compliance with minimum energy performance standard requirements. Accessed by ISONET - CHINA STATE B
10、UREAU OF TECHNICAL SUPERVIS on 15 Oct 20099 AS/NZS 3823.2:2009 COPYRIGHT 1.5 REFERENCED DOCUMENTS The following documents are referred to in this Standard: AS 2706 Numerical valuesRounding and interpretation of limiting values 4755 Framework for demand response capabilities and supporting technologi
11、es for electrical productsDemand response capabilities and supporting technologies for electrical products 4755.3.1 Part 3.1: Interaction of demand response enabling devices and electrical productsOperational instructions and connections for airconditioners AS/NZS 3823 Performance of household elect
12、rical appliancesAirconditioners and heat pumps 3823.1.1 Part 1.1: Test methodsNon-ducted airconditioners and heat pumpsTesting and rating for performance 3823.1.2 Part 1.2: Test methodsDucted airconditioners and air-to-air heat pumpsTesting and rating for performance 3823.1.3 Part 1.3: Water-source
13、heat pumpsWater-to-air and brine-to-air heat pumpsTesting and rating for performance 3823.3 Part 3: Calculation of performance for minimum energy performance standard (MEPS) requirements 4776 Liquid-chilling packages using the vapour compression cycle 4776.2 Part 2: Minimum energy performance standa
14、rd (MEPS) and compliance requirements 4965 Performance of close control airconditioners 4965.2 Part 2: Minimum energy performance standard (MEPS) requirements 62301 Household electrical appliancesMeasurement of standby power 1.6 DEFINITIONS For the purposes of this Standard the definitions given in
15、AS/NZS 3823.1.1, AS/NZS 3823.1.2, AS/NZS 3823.1.3 and those below apply. 1.6.1 Annual Coefficient of Performance (ACOP) Annual Coefficient of Performance as defined in accordance with Clause 2.5. 1.6.2 Annual Energy Efficiency Ratio (AEER) Annual Energy Efficiency Ratio as defined in accordance with
16、 Clause 2.5. 1.6.3 Average true power factor The average true power factor over a given time is the kWh divided by the kVAh. NOTE: It is not the average of regular instantaneous power factor measurements. 1.6.4 Check test A full or part test in accordance with AS/NZS 3823.1.1, AS/NZS 3823.1.2, AS/NZ
17、S 3823.1.3 or a simulation assessment to AS/NZS 3823.3, as applicable, to verify the performance or energy consumption, or both, of an individual model. 1.6.5 Chiller A product that falls within the scope of AS/NZS 4776. 1.6.6 Close control air conditioners A product that falls within the scope of A
18、S/NZS 4965. Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 15 Oct 2009AS/NZS 3823.2:2009 10 COPYRIGHT 1.6.7 Demand response capable An air conditioner that is supplied with the necessary interface, circuitry and components to comply fully with AS 4755.3.1. NOTE: Air conditioners th
19、at are assembled from components on site are demand response capable if all components necessary to make the assembly demand response capable are supplied with every unit, and the installation instructions require all components to be assembled. 1.6.8 Ducted air conditioners An air conditioner model
20、 configuration where the indoor side is situated remote to the space to be conditioned. The conditioned air is supplied or extracted via a duct. 1.6.9 Family of models A range of models of the one brand, for which a single set of test reports is applicable and where each of the models has the same r
21、elevant physical characteristics, energy efficiency rating, performance characteristics and refrigerant. The term model is synonymous with family of models. NOTE: A product that has single-phase and three-phase variants will have to be separately registered and cannot be considered as one family (as
22、 MEPS requirements for single- and three-phase variants may be different). Single- and three-phase products may be separately registered using a single test report that covers these variants, as long as the product tested has the lowest EER and COP of all the relevant variants. 1.6.10 Grandfathering
23、 Refer to the Administrative Guidelines and Paragraph F3 for details. 1.6.11 Multi-split system A split system air conditioner with a refrigeration system having two or more indoor units, each indoor unit being independently controlled. 1.6.12 Non-ducted air conditioner An air conditioner model conf
24、iguration where the indoor side is situated partly or wholly within the space to be conditioned. The conditioned air is directly supplied to and extracted from the conditioned space. 1.6.13 Potentially demand response capable An air conditioner that is potentially fully compliant with AS 4755.3.1, o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASNZS382322009PERFORMANCEOFELECTRICALAPPLIANCESAIRCONDITIONERSANDHEATPUMPSENERGYLABELLINGANDMINIMUMENERGYPERFORMANCESTANDARDMEPSREQUIREMENTS

链接地址:http://www.mydoc123.com/p-450053.html