1、*USACE / NAVFAC / AFCESA / NASA UFGS-03 52 16 (April 2008)-Preparing Activity: USACE SupersedingUFGS-03 51 00 (October 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2007*SECTION TABLE OF CONTENTSDIVISION 03 - CONCRETESECTION 03 52 16LIGHTWEIGHT INSUL
2、ATING CONCRETE04/08PART 1 GENERAL1.1 REFERENCES1.2 DESIGN REQUIREMENTS1.2.1 Concrete1.2.2 Required U-Value1.2.3 Steel Forms1.3 SUBMITTALSPART 2 PRODUCTS2.1 MATERIALS2.1.1 Admixtures2.1.2 Aggregate2.1.3 Foaming Agent2.1.4 Cementitious Material2.1.5 Wire Reinforcement2.1.6 Steel Forms2.1.7 Rigid Insul
3、ation2.1.8 Expansion Joint Materials2.2 MIXING PROCEDUREPART 3 EXECUTION3.1 FORMWORK3.2 WIRE REINFORCEMENT3.3 LOW DENSITY CONCRETE CONVEYING AND PLACEMENT3.4 EXPANSION JOINTS3.5 COLD WEATHER PLACEMENT3.6 CURING3.7 FIELD-CONTROL TESTS3.7.1 Wet-Density Tests3.7.2 Compressive Strength Tests3.8 CLEANING
4、 AND PROTECTION- End of Section Table of Contents -SECTION 03 52 16 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SECTION 03 52 16 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE
5、/ NAVFAC / AFCESA / NASA UFGS-03 52 16 (April 2008)-Preparing Activity: USACE SupersedingUFGS-03 51 00 (October 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2007*SECTION 03 52 16LIGHTWEIGHT INSULATING CONCRETE04/08*NOTE: This guide specification cov
6、ers the requirements for low density cast-in-place concrete roof decking.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not re
7、quired in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number,
8、 is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation
9、 only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Referenc
10、e feature to update SECTION 03 52 16 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile refer
11、ences in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.AMERICAN IRON AND STEEL INSTITUTE (AISI)AISI SG03-3 (2002) Cold-Formed Steel Design Manual SetA
12、MERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (ASHRAE)ASHRAE FUN IP (2005) Fundamentals Handbook, I-P EditionASHRAE FUN SI (2005) Fundamentals Handbook, SI EditionAMERICAN WELDING SOCIETY (AWS)AWS A2.4 (2007) Standard Symbols for Welding, Brazing and Nondestructive Examina
13、tionASTM INTERNATIONAL (ASTM)ASTM A 185/A 185M (2007) Standard Specification for Steel Welded Wire Reinforcement, Plain, for ConcreteASTM A 653/A 653M (2007) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM A 82/A 82
14、M (2007) Standard Specification for Steel Wire, Plain, for Concrete ReinforcementASTM C 150 (2007) Standard Specification for Portland CementASTM C 260 (2006) Standard Specification for Air-Entraining Admixtures for ConcreteASTM C 332 (2007) Lightweight Aggregates for Insulating ConcreteASTM C 495 (
15、2007) Compressive Strength of Lightweight Insulating ConcreteASTM C 578 (2007) Standard Specification for Rigid, Cellular Polystyrene Thermal InsulationASTM C 595 (2007) Standard Specification for Blended Hydraulic CementsSECTION 03 52 16 Page 4Provided by IHSNot for ResaleNo reproduction or network
16、ing permitted without license from IHS-,-,-ASTM C 796 (2004) Foaming Agents for Use in Producing Cellular Concrete Using Preformed FoamASTM C 869 (1991; R 2006) Foaming Agents Used in Making Preformed Foam for Cellular Concrete1.2 DESIGN REQUIREMENTSProvide services of a firm experienced in the inst
17、allation of cast-in-place low density roof systems. A representative of the firm shall supervise the mixing, transporting, placing, finishing, and testing the low density concrete.1.2.1 Concrete*NOTE: Oven-dry unit weight of low density concrete should not exceed 800 kg/cubic meter (50 pcf); nor sho
18、uld the compressive strength exceed 3100 kPa (450 psi). Insulation value decreases with high unit weights. Unit weight of 400 kg/cubic meter (25 pcf) with a minimum compressive strength of 862 kPa (125 psi) will normally be specified. Manufacture of this type of concrete is specialized and manufactu
19、rers data should be relied on to establish mixture proportions. See ACI 523.1R for additional information.*Establish the strength qualities of the low density concrete proposed for use from manufacturers submitted data prior to the beginning of construction operations. Perform the preparation of the
20、 design mix and subsequent testing through an approved testing laboratory capable of performing such services or, if approved, by the manufacturer of the low density concrete. Prepare trial design batches with the same materials proposed for use in the work. Make and test Test Cylinders in accordanc
21、e with ASTM C 495 for perlite and vermiculite concrete and ASTM C 796 for cellular concrete. Proportion low density concrete for a minimum oven-dry unit weight of 400 _ kg/cubic meter 25 _ pcf and the minimum average compressive strengths at 28 days of 862 _ kPa 125 _ psi.1.2.2 Required U-ValueThe a
22、ctual average installed thickness of concrete, forms, and insulation, if used, shall be sufficient to provide a coefficient of heat transmission, or U-value, based on winter conditions, through the affected construction, not in excess of _ W per square meter, per degree K Btu per hour, per square fo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS0352162008LIGHTWEIGHTINSULATINGCONCRETE 质保 混凝土 PDF

链接地址:http://www.mydoc123.com/p-449552.html