1、 . a O NIL-R-51SLb 10 779970b 033q303 5 E - 3/43 MIL-R-515 16 ( EA) 16 January 1986 (See section 6) MILITARY SPECIFICATION SMTULATOR, PRESSURE, RIOT CONTROL AGENT DISPERSER This specification is approved for use within U.S. Army Chemical Research and Development Center, Department of the Army, and i
2、s available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE ,. Scope. This specification covers one type of pressure regulator. 2. APPLICABLE DOCUMENTS 2 . 1 Government documents . 2.1.1 Standards, The following standards form a part of this specification to the extent
3、 specified herein. these documents shall be those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISC) and supplement thereto, cited in the solicitation. Unless otherwise specified, the issues of STANDARDS MILITARY MTL-STD-105 - Sampling Procedures and Tabl
4、es for Inspection by MIL-STD-129 - Marking for Shipment and Storage. MIL-STD-130 - MIL-STD-810 - Environmental Test Methods and Engineering Guidelines. Attributes. Ident if icat ion Marking .of US Military Property . 2.1.2 Other Government documents and drawings. The following other Govern- ment doc
5、uments and drawings form a prt of this specification to the extent specified herein. Unless otherwise specified, the issues shall be those in effect on the date of the solicitation. : Beneficial comments (recommendations, additions, deletions) and any perti- : : nent data which may be of use in impr
6、oving this document should be addressed: : to: Commander, U.S. Army Chemical Research and Development Center, AWN: : SMCCR-SPD-TS, Aberdeen Proving Ground, MD 21010-5423 by using the self- : addressed Standardization Document Improvement Proposal (DD Form 1426) : appearing at the end of this documen
7、t or by letter. AMSC N/A FSC 1040 - DISTRIBLTFION STATEMENT A. Approved for public release; distribution is unlimited. THIS DOCUMENT CONTAINS y- PAGES. I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-c- -. MIL-R-SL516 LO M 777970b 0334304 7 DRAWING
8、S AND TECHNICAL DATA PACKAGE LIST (TDPL) UtS. ARMY ARMAMENT, MUNITIONS AND CHEaUIICAL COMMAND CHEMIC& RESEARCH AND DEVELOPMENT CENTER TDPL 116-3-92 - Regulator, Pressure, Riot ControI Agent Disperser. (Copies of standards , drawings and other Government documents required by contractors in connectio
9、n with specific acquisition functions should be obtained from the contracting activity or as directed by the contracting activity. 2.2 Other publications. The following document forms a part of this speci- fication to the extent specified herein. Unless otherwise specified, the issues of the documen
10、ts which are DOD adopted shall be those listed in the issue of the DODISS specified in the solicitation. Unless otherwise specified, the issues af documents not listed in the DODISS shall be the issue of the non- government documents which is current on the date of the solicitation. UNIFORM CLASSIFI
11、CATION COMMITTEE Uniform Freight Classification Ratings, Rules and Regulations. (Application for copies of these freight classification ratings, rules, and regulations should be addressed to the Uniform Classification Committee, 202 Union Station, Chicago, Illinois 60606. ) (Nongovernment standards
12、and other publications are normally available from the organizations which prepare or which distribute the documents. These docu- ments also may be available in or through libraries or other informational ser- vices.) 2.3 Order of precedence. in the event of a conflict between the text of this speci
13、fication and the references cited herein ( except for associated detail specifications, specification sheets or MS standards), the text of this specification shall take precedence. Nothing in this specification, however, shall supersede applicable laws and regulations unless a specific exemption has
14、 been obtained. 3 REQUIREMENTS 3.1 Materials and components. 3.1.1 Materials. All materials used in the mnufacture of the regulator shall conform to the specifications forming a part of this specification. Materials not definitely specified shall be at- an accepted commercial type and grade suitable
15、 for the purpose intended. and imperfections that might affect serviceability of the assembled product. Material shall be free from defects 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-51516 20 M 7777906 0334305 7 J MIL-R-51516 ( EA) 3.1.2
16、 Components. All components shall be of an accepted commercial type and of the manufacturers latest design. 3.2 Design. The regulator shall be complete and capable of operation under the conditions speckfied in this specification. All regulators procured under this specification from one contractor
17、shall be physically and mechanically identical (Drawing 116-3-92). personnel. for 50,000 cycles (a cycle is designated as a 3 second flow of regulated air) . The regulator shall have an adjustment feature to obtain the setting specified in 3.3. The regulator shall be capable of operating at temperat
18、ures of -40“ to +l55“F. The weight of the regulator shall not exceed 1.0 pound. Regulators shall be of a design not hazardous to The regulator shall be capable of maintaining its rated functioning The adjustment shall be suitably designed to discourage tampering. 3.3 Functioning and leakage. The reg
19、ulator shall not leak and shall main- tain an outlet pressure of i80 + 20 pounds per square inch gage (,pig) at a flow rate of O to 30 standard cubic feet per minute (scfm) (40“F at 14.7 pounds per square inch (psi) of clean air or nitrogen at inlet pressures of 360 2 50 psig and 2100 (+lo0 or -0) p
20、isg and there shall be no pressure rise for the last minute of a three minute period when tested in accordance with 4.4.4 .i. 3.4 High temperature. The regulator shall conform to 3.3 when tested at +155“F as specified in 4.3.3.1. 3.5 Low temperature. The regulator shall conform to 3.3 when tested at
21、 -40F as specified in 4.3.3.1. 3.6 Temperature shock. The regulator shall conform to 3.3 when tested as specified in 4.3.3.1. 3.7 Salt fog, The regulator shall conform to 3.3 when tested as specified in 4.3.3.1. 3.8 Dust. The regulator shall conform to 3.3 when tested as specified in 4.3.3.1. 3.9 Pr
22、oof pressure. The regulator shall not leak and shall be free from per- manent deformation and damage when subjected to a minimum pressure of 3300 psig as specified in 4-4.4.2 (see 6.3). 3-10 Cyclic functioning. The regulator shall conform to 3.3 when cycled in accordance with table I and tested as s
23、pecified in 4.3.3.2. 3.11 Vibration. The regulator shall conform to 3.3 after testing as speci- fied in 4.3.3.3. 3-12 Mechanical shock. The regulator shall conform to 3.3 after testing as specified in 4.3.3.4. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro
24、m IHS-,-,-MIL-R-SLSLb LO H 797990b 0334306 O i MIL-R-51516( EA) TABLE I. Criteria for failure rate testing Column I Column II : Number of failures : Cumulative time (cycles) (see 3.2) : 1 30,000 2 48,000 3 63,000 78,000 92,ooo 4 105,000 5 11g,000 6 132,000 7 8 145,000 . 9 10 157,000 The above cumula
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILR515161986REGULATORPRESSURERIOTCONTROLAGENTDISPERSER 暴动 控制 介质 分散剂 压力 标准 PDF

链接地址:http://www.mydoc123.com/p-447782.html