1、 MIL-PRF-bZ331A W 9Ob 2045335 455 I INCH-POUND I MIL-PRF-6233 lA(AT) 15 August 1997 SUPERSEDING 30 March 1984 MTL-P-6233 l(AT) PERFORMANCE SPECIFICATION PUMP ASSEMBLY, BILGE, ELECTRIC MOTOR DRIVEN, DIRECT CURRENT This specification is approved for use by U.S. Army Tank-automotive and Armaments Comma
2、nd, Department of the Army, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the performance and design requirements for an electric motor driven pump assembly which evacuates water from M60 series tanks. 2. APPLICAB
3、LE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to
4、ensure the completeness of this list, document users are cautioned that they must meet all specified requirement documents cited in sections 3 and 4 of this specification, whether or not they are listed. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be
5、of use in improving this document should be addressed to: U. S. Army Tank-automotive and Armaments Command, ATTN: AMSTA-TR-E/BLUE, Warren, MI 48397-5000, by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document, or by letter. AMSC N/A FSC 4320 D
6、ISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Licensed by Information Handling ServicesMIL-PRF-623 3 1 A(AT) 2.2 Government documents. 2.2.1 Specifications. standards. and handbooks. The following specifications, standards, and handbooks form a part of this documen
7、t to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6.2). STANDARDS DEPARTMENT OF DEFENSE MIL-STD-4
8、62 - Electromagnetic Interference Characteristics MIL-STD-810 Measurements of - Environmental Test Methods and Engineering Guidelines. (Unless otherwise indicated, copies of the above specifications, standards, and handbooks are available from the Standardization Document Order Desk, 700 Robbins Ave
9、nue, Building 4D, Philadelphia, PA 191 11-5094.) 2.2.2 Other Government documents. drawings. and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in t
10、he solicitation. DRAWINGS ARMY 7059833 - Bilge Pump Assembly (Interface). (Copies of these drawings are available from the U. S. Army Tank-automotive and Armaments Command, ATTN: AMSTA-TR-E/BLUE, Warren, MI 48397-5000.) 2.3 Non-Government publications. The following documents form a part of this doc
11、ument to the extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issues of the documents cite
12、d in the solicitation (see 6.2). 2 Licensed by Information Handling ServicesMIL-PRF-6233 lA(AT) AMERICAN NATIONAL STANDARD INSTITUTE (ANSI) ANSUASQC 21.4 - Sampling Procedures and Tables for Inspection by Attributes OD Adopted). (Application for copies should be addressed to American National Standa
13、rd Institute (ANSI), 11 West 42nd Street, New York, NY 10036.) NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) MG1-4.21 - Method of Measuring the Motor Vibration (Dynamic Balance) OD Adopted). (Application for copies should be addressed to the National Electrical Manufacturers Association, 2101
14、 L Street, NW, Washington, DC 20037.) 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exe
15、mption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified, a sample shall be subjected to first article inspection in accordance with 4.3 (see 6.2). 3.2 Materials. Materials shall be in accordance with the manufacturers materials specifications for pumps. Materials shall be capable
16、 of meeting all operational and environmental requirements specified herein and shall be fkee of defects which adversely affect performance or serviceability of the finished product. Asbestos and cadmium materials shall not be used in any form in any part of the pump. No item, part or assembly shall
17、 contain radioactive materials in which the specific activity is greater than 0.002 microcuries per gram or activity per item equals or exceeds 0.01 microcuries (see 4.5.1). 3.2.1 Metals and finishes. Exposed functional parts shall be fabricated from suitable corrosion resistant material or treated
18、to prevent corrosion. Exposed nonfunctional parts shall be painted white in accordance with the manufacturers standard (see 4.5.1). 3.2.2 Fungistatic materials. All non-metallic materials shall be inherently fungistatic or treated to resist fungus growth except when used for components of potted or
19、otherwise moisture sealed assemblies (see 4.5.1). 3 Licensed by Information Handling Services MIL-PRF-62331A 9999906 2045338 164 MIL-PRF-623 3 1 A(AT) 3 2.3 Recvcled. recovered. or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to th
20、e maximum extent possible provided that the materials meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.3 Design and construction. Pump assemblies shall conform to the envelope dimension, inletloutlet port locations and dimensio
21、ns, and the electrical and mounting interfaces as shown in drawing 7059833 (see 4.5.1). 3.3.1 Interchangeability. All similar parts including repair parts of the motor assembly funriished on the same order or built to the same drawings shall be completely interchangeable without further machining se
22、lective assembly or hand fitting of any kind (see 4.5.1). 3.4 Performance. Unless otherwise specified, the pump assembly shall meet the performance requirements under the following conditions: a. Air temperature 73 i 18 degrees Fahrenheit (“F) b. Pressure 28.5 (+2.0, -4.5) inches of mercury (Hg) c.
23、Humidity 50 30 percent (“A) d. Voltage 27.5 ? 0.5 volts (V) direct current (dc) 3.4.1 Voltage range. The pump assembly shall operate between 18 and 30 Vdc. The output at 18 Vdc shall be not less than 30 gallons per minute (gdmin) minimum at 12 foot (fi) total discharge head (TDH) and at 30 Vdc not l
24、ess than 115 gdmin at a 12 A TDH (see 4.5.2). 3.4.2 Current draw. The current draw of the pump assembly shall be as shown in figure 1 (see 4.5.3). 3.4.3 Efficiency. The pump assembly shall have an efficiency as shown in figure 1 (see 4.5.4). 3.4.4 Flow rate. The pump assembly shall have a free flow
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF62331A1997PUMPASSEMBLYBILGEELECTRICMOTORDRIVENDIRECTCURRENT 电机 驱动 直流 舱底泵 机组 PDF

链接地址:http://www.mydoc123.com/p-447560.html