1、-_ 7 MIL-P-60345 13 7777706 0337828 L W MIL4?-60345(Mu) 25 MAY 1965 SUPERSESSION NOTE (SEE 6.5) MILITARY SPECIFICATION PRIMER, STAB, M45 LOADING, ASSEMBLING AND PACKING 1. SCOPE 1.1 “his specification covers the loading, assembling and packing for one type of pri- mer designated as Primer, Stab, M45
2、. 2. APPLICABLE DOCUMENTS 2.1 The following documents of the issue in effect on date of invitation for bids, or re- quest for proposals, form a part of this spec- ification to the extent specified herein. SPECIFICATIONS MARY MIGP-116 -Preservation, Methods of. MIG.A-2650 - Ammunition and Spe- cial W
3、eapons; Gen- eral Specification for. MIGP-12059 -Powder. Sulfurless . Meal. MILI45607 -Inspection Equipment, Supply and Main- tenance of. STANDARDS MILITARY . MILSTD-105 - Sar?tp?Iirig Procedures and Tables for In- spection by Attri- butes (ABGSTD- 105). MILSTI)-109 - Quality Assurance Terms and Def
4、ini- tiOIl8. MIL-SBO - Explosives : Sampling, Inspection and Test- ing. MIL-STD-1235- Single and Multilevel Continuous Sam- pling Procedures and Tables for In- spection by Attri- butes. DRAWINGS ORDNANCE CORPS 7648099 -Box, Packing, Ammu- nition for Detona- tors. Ammunition, Outer for Small Explosiv
5、e Components. 7648104 -Box, Setcup, Packing, Ammunition, Inner for Small Ehsplosive Components. 7648103 -BOX, Set-up, Packing, THIS DOCUMENT CONTAINS /I PAGES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-60345 13 777770b 0337827 3 MIL-P-603
6、45 (MU) 9207643 -Primer, Stab. the batch or blend of batches of primer mixture shall be re- jected. If loading has begun, action on the unloaded primer mixture shall be as specified above and all primers loaded with the ques- tionable primer mixtcre shall be rejected. 4.2.3.3 Functioning. 6 Provided
7、 by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-_ MIL-P-h03i5 13 4797406 0337833 5 = MIL-P-60345 (MU) 4.2.3.3.1 Seiisiti:tg (see 3.5.1 )-Mu jor de- fect-Code :o. O!?OOl. A sample of 315 primers shall be selected at random from each lot. If 3 or more primers
8、fail to comply xith the requirement specified, the lot shall be rejected. If one or two defectives are found, a second sample of 315 primers shall be selected a random and tested. If in the combined first and second sample a total of 4 or more defectives are found, the lot shall be rejected. The tes
9、t shall be performed as specified in 4.3.3.1 using test equipment as specified in 4.2.4. 4 :2.3.3.2 aspirated with suction and the bottom of the crucible wiped dry, using tissue paper. The washing shall be continued, using one more 3.0 ml. portion, two 2.0 ml. and two 1.0 nil. portions, making a tot
10、al of 12.0 ml. The crucible shall be removed and the bottom of the crucible. the funnel, the adapter and the suction flask washed with water. The test tube shall be placed in the flask and the stem of the filter- ing funnel inserted into the test tube. The crucible and contents shall be washed with
11、one 1.0 ml. portion of Solution Number 1 as above, and aspirated with suction, catching the filtrate in the test tube, The test tube shall be removed, 1.0 ml. of distilled water added and the chlorzte ion, determined as follows. The tube shall be inclined at an angle of about 4.5 degrees ana from a
12、dropper about 0.0 ml. of a solution containkg 1.0 gm. of diphenylamine in 100 gm. cf concentrated salfuric acid shall be run down the side of the tube, so that there will )e two distinct layers. If an appreciable amomt of chlorate ion is present, a distinct b1i:e ring will be visible at the border o
13、f the two layers. On shaking the tube, the ring disappears, but the coiiteiits assume a blue coloiation, which lasts several seconds, depending on the amount of chlorate ion present. If only a trace of chlorate ion is present the blue ring may not form, but upon shaking the test tube, a slight bluis
14、h coloration will appear momentarily throughout the solution, lasting only a fraction of a second. If a definite blue ring forms, the washing shall be repeated as before using one 1.0 ml. portion of Solution Number 1, and finally a 0.5 ml. portion of the same soiution, as needed, depending on the ou
15、tcome of the tests for the chlorate ion. (Usually a Wal of 14.0 or 14.6 ml. of Solu- tion Xumber 1 is sufficient.) After complete removal of potassium chlorate the inside of the crucible shall be washed with 1.0 ml. of Solution Number 2 and aspirated immedia- tely. The bottom of the crucible shalt h
16、e wiped dry with tissue paper and dried in an oven at 80 degrees C. plus or minus 1 degree C. for 30 minutes, cooled in a desiccator and weighed. The percentage of potassium chlor- ate shall be calculated as follows: Potassium Chlorate, percent = 100B w(i-Mj where : R : :. loss in weight of contents
17、 of cru- IV i- weight of sample, grams. .If = percent moisture cible, grams. 100 4.3.2.2.2 Antimony sulfide. 4.3.2.2.2.1 Preparatiw of soliitioii of Fer- rir ammoiiizcm sulfate. To approximately 120 7 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-M
18、IL-P-60345 13 m 7774706 0337835 9 m MILP-40345 (MU) ml. of distilled water, in a one-half liter re- agent bottle, 125 m. of ferric ammonium sulfate shall be added. The bottle shall be stoppered and shaken vigorously for several minutes and then allowed to stand overnigh. Portions of the saturated so
19、lution shall be filtered before using. 4.3.2.2.2.2 Procediire. A portion of approx- imately 1 gm. of the sample shall be accur- ately weighed directly into a tared 30 ml. sin- tered glass crucible of medium porosity. Five ml. of one percent nitric acid shall be added and the crucible constantly swir
20、led for one minute in order to dissolve all the ingredients of the powder except antimony sulfide. Care shall be taken not to spill any liquid. The mixture shall be filtered by applying suction employing a vacuum flask, The crucible shall be removed from the adapter and the bottom wiped dry with tis
21、sue paper, The operations of washing, using 5.0 ml. of one percent nitric acid each time and swirling for exactly one minute shall be repeated. After a total of 40 ml, of one percent nitric acid has been used, the crucible shall be removed and the bottom of it washed with water. The funnel, the funn
22、el adapter and the vacuum flask shall be washed with water; the filtrate and washings shall be discarded. About 1 ml. of a saturated solution of ferric ammonium sul- fate shall be placed in the flask. The contents of the crucible shall be treated as before with 0.0 ml. of one percent nitric acid and
23、 filtered by means of suction into the flask. If the liquid in the flask turns red, due to the pre- sence of the thiocyanate ion in the filtrate, the washing of the contents in the crucible shall be repeated with additional 5.0 ml. por- tions of one percent nitric acid until a nega- tive test for th
24、e sulfocyanate ion is affected. (Usually a total of 50 ml. is sufficient.) The crucible and contents shall be rinsed with alcohol and then with ether, and then aspir- ated until the odor of ether is no longer de- tectable. The crucible and contents shall be dried in an oven at 80 degrees C. plus or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILP603451965PRIMERSTABM45LOADINGASSEMBLINGANDPACKINGM45 针刺 引物 组装 包装 PDF

链接地址:http://www.mydoc123.com/p-446646.html