ARMY MIL-C-48605A-1991 CONTROL ASSEMBLY R F (UNIT 1) 11748205.pdf
《ARMY MIL-C-48605A-1991 CONTROL ASSEMBLY R F (UNIT 1) 11748205.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-C-48605A-1991 CONTROL ASSEMBLY R F (UNIT 1) 11748205.pdf(45页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-C-48605A 12 9997906 0483300 9 MIL-C-48605A (AR) 14 June 1991 SUPERSEDING MIL-C-48605 (AR) 30 September 1980 MILITARY SPECIFICATION CONTROL ASSEMBLY R.F. (UNIT 1) 11748205 This specification is approved for use by U.S. Army Armament, Munitions and Chemical Command, and is available for use by al
2、l Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the Control Assembly R.F. (Unit l), hereinafter referred to as control assembly, used with the System Tester, Radar AN/VPM-2, 11748124 (see 6.1). 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2
3、.1.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specif
4、ications and Standards (DODISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS MILITARY MIL-F-13926 - Fire Control Materiel, Manufacture and MIL-1-45607 - Inspection Equipment, Acquisition, MIL-S-48431 - Solid State X-Band Source 10548182 MIL-P-48606 - Power Supply Assem
5、bly (Unit 2) 11748133 Inspection, General Specification for Maintenance and Disposition of eneticiai comments (recommeiatiarr, additions, deletions) and any pertinent daia which may lx of use in improving this doaunent shouid be aclcksd to: canmaoder, U.S. Army ARDEC, Am. SMCAR-BAGS, picatinay Arsen
6、al, New Jersey M806-5000 by using tbe edf-addresred staodarbiza * tim Doaunent Improvement nopoSai (DD Form 1426) appearing at thcd of this document or by kkr. Fsc 1240 AMSC NA ST4TEMF.NT 4, Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or netwo
7、rking permitted without license from IHS-,-,-_ _ - MIL-C-48b05A 12 m 9999906 0483303 O = MIL-C-48605A (AR) I STANDARDS MILITARY MIL-STD-109 - Quality Assurance Terms and Definitions MIL-STD-810 - Environmental Test Methods and Engineering MIL-STD-2000 - Standard Requirements for Soldering Guidelines
8、 Electrical and Electronic Assemblies (Unless otherwise indicated, copies of federal and military specifications, standards, and handbooks are available from the Standardization Documents Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094.) 2.1.2 Other Government documents, dra
9、winqs, and publications. The following other Government documents, drawings, and publications form a part of this specification to the extent specified herein. Unless otherwise specified, the issues shall be those in effect on the date of the solicitation. DRAWINGS (see 6.4) U.S. ARMY ARMAMENT RESEA
10、RCH, DEVELOPMENT AND ENGINEERING CENTER (ARDEC) 10549058 - 11748133 - 11748144 - 11748155 - 11748168 - 11748205 - 11748213 - 11748214 - 11748215 - 11748216 - 11748455 - Radar Set AN/VPS-2 Power Supply Assembly (Unit 2) W5 Waveguide Flexible RF Amplifiers Microwave Integrated Assembly #i Control Asse
11、mbly R.F. (Unit 1) Cable, W1 Power Supply Cable, W2 Signal input Cable, W3 Power input Cable, W4 Data Input Microwave nteqrated Assembly #5 - 11748460 - Wire List PACKAGING DATA SHEET PS11748205 - Packaging of Control Assembly R.F. (Unit 1): 11748205 (Copies of drawings, publications, and other Gove
12、rnment documents required by contractors in connection with specific acquisition functions should be obtained from the contracting activity or as directed by the contracting activity.) 2.2 Order of precedence. In the eventof conflict between the text of this document and the references cited herein,
13、 the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-48605A 12 = 9999906 0483
14、302 2 MIL-C-48605A (AR) 3. REQUIREMENTS 3.1 Materials. Materials shall be in accordance with the applicable drawings and specifications. 3.2 Components and assemblies. The components and assemblies shall comply with all requirements specified on Drawing 11748205, all associated drawings, and with al
15、l requirements specified in applicable specifications and standards. Where applicable, the control assembly shall meet the requirements of MIL-F-13926 as follows : 3.3 a. Dimensions and tolerances. b. Inorganic protective surface finishings, c. Part identification and marking. d. Workmanship. Enviro
16、nmental service conditions. 3.3.1 Vibration. The control assembly shall not suffer damage and shall meet the requirements of 3.4 and 3.5 after exposure to sinusoidal vibrations, in each of three mutually perpendicular axes, as follows: Frequency Ranqe Amplitude 10 to 15 hertz 0.06 inches double ampl
17、itude 15 to 25 hertz 0.04 inches double amplitude 25 to 55 hertz 0.02 inches doub.le amplitude The frequency of vibration shall be swept logarithmically. The cycling time shall be 120 minutes per axis. The sweep rate shall be 3.75 minutes +io% per decade. The 10-55-10 hertz sweep time is 3 mikrtes 4
18、5 seconds +lo%. - 3.3.2 Altitude. 3.3.2.1 Operating. The control assembly shall meet the requirements of 3.4 and 3.5 during and after exposure to barometric pressure encountered at 10,000 feet above sea level (20.6 inches of Hg) 3.3.2.2 Non-operating. The control assembly shall meet the requirements
19、 of 3.4 and 3.5 after exposure for not less than i0 minutes to barometric pressure encountered at 40,000 feet above sea level (5.5 inches of Hg). 3.3.3 Temperature. 3.3.3.1 Operatinq. The control assembly shall meet the requirements of 3.4 and 3.5 when stabilized thermally at any temperature between
20、 -40 degrees F and +155 degrees F. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-48605A (AR) 3.3.3.2 Non-operating (storaqe). The control assembly shall not suffer permanent damage when subjected to the constant temperature extremes of -60
21、degrees F for a period of 24 hours and +160 degrees F for a period of 4 hours (after temperature stabilization) and shall meet the requirements of 3.4 and 3.5 when returned to room ambient. 3.3.4 Humidity (non-operating). The control assembly shall meet the requirements of 3.4 and 3.5 after exposure
22、 to an atmosphere with a relative humidity in excess of 95 percent for a period of 10 days. 3.3.5 Immersion (non-operatinq). The control assembly shall meet the requirements of 3.4 and 3.5 and shall have no evidence of water penetration within the case after being immersed in water and subjected to
23、a positive pressure equivalent to 3 head-feet of water (approximately 1.3 psi) for a period of two hours. The power supply assembly shall be immersed with its case closed, an equivalent dummy load, and a sealed plug in place of the pressure release valve. 3.4 Electrical. Each conductor shall be elec
24、trically 3.5 Performance. continuous as specified on drawing 11748460. 3.5.1 Primary input power. The control assembly shall be capable of meeting all requirements of this specification with +24 - +6 Vdc primary input power applied to a Power Supply Assembly (Unit 2) P/N 11748133 that meets all the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILC48605A1991CONTROLASSEMBLYRFUNIT111748205PDF

链接地址:http://www.mydoc123.com/p-441644.html