1、 TECHNICAL REPORT ANSI/ISATR12.21.012004 (R2013) Use of Fiber Optic Systems in Class I Hazardous (Classified) Locations ANSI Technical Report prepared by ISA Approved 1 September 2013 ANSI/ISA-TR12.21.01-2004 (R2013) Use of Fiber Optic Systems in Class I Hazardous (Classified) Locations ISBN: 978-0-
2、876640-30-2 Copyright 2013 by the International Society of Automation (ISA). All rights reserved. Not for resale. Printed in the United States of America. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means (electronic mechanical, p
3、hotocopying, recording, or otherwise), without the prior written permission of the Publisher. ISA 67 Alexander Drive P.O. Box 12277 Research Triangle Park, North Carolina 27709 3 ANSI/ISA-TR12.21.01-2004 (R2013) Copyright 2013 ISA. All rights reserved. Preface This preface, as well as all footnotes
4、and annexes, is included for information purposes and is not part of ANSI/ISA-TR12.21.01-2004 (R2013). This document has been prepared as part of the service of ISA toward a goal of uniformity in the field of instrumentation. To be of real value, this document should not be static but should be subj
5、ect to periodic review. Toward this end, the Society welcomes all comments and criticisms and asks that they be addressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive; P. O. Box 12277; Research Triangle Park, NC 27709; Telephone (919) 549 -8411; Fax (919) 549-8288; E-mail
6、: standardsisa.org. The ISA Standards and Practices Department is aware of the growing need for attention to the metric system of units in general, and the International System of Units (SI) in particular, in the preparation of instrumentation standards. The Department is further aware of the benefi
7、ts to USA users of ISA standards of incorporating suitable references to the SI (and the metric system) in their business and professional dealings with other countries. Toward this end, this Department will endeavor to introduce SI-acceptable metric units in all new and revised standards, recommend
8、ed practices, and technical reports to the greatest extent possible. IEEE/ASTM SI 10, American National Standard for Metric Practice, and future revisions, will be the reference guide for definitions, symbols, abbreviations, and conversion factors. It is the policy of ISA to encourage and welcome th
9、e participation of all concerned individuals and interests in the development of ISA standards, recommended practices, an d technical reports. Participation in the ISA standards-making process by an individual in no way constitutes endorsement by the employer of that individual, of ISA, or of any of
10、 the standards, recommended practices, and technical reports that ISA develops. CAUTION ISA DOES NOT TAKE ANY POSITION WITH RESPECT TO THE EXISTENCE OR VALIDITY OF ANY PATENT RIGHTS ASSERTED IN CONNECTION WITH THIS DOCUMENT, AND ISA DISCLAIMS LIABILITY FOR THE INFRINGEMENT OF ANY PATENT RESULTING FR
11、OM THE USE OF THIS DOCUMENT. USERS ARE ADVISED THAT DETERMINATION OF THE VALIDITY OF ANY PATENT RIGHTS, AND THE RISK OF INFRINGEMENT OF SUCH RIGHTS, IS ENTIRELY THEIR OWN RESPONSIBILITY. PURSUANT TO ISAS PATENT POLICY, ONE OR MORE PATENT HOLDERS OR PATENT APPLICANTS MAY HAVE DISCLOSED PATENTS THAT C
12、OULD BE INFRINGED BY USE OF THIS DOCUMENT AND EXECUTED A LETTER OF ASSURANCE COMMITTING TO THE GRANTING OF A LICENSE ON A WORLDWIDE, NON-DISCRIMINATORY BASIS, WITH A FAIR AND REASONABLE ROYALTY RATE AND FAIR AND REASONABLE TERMS AND CONDITIONS. FOR MORE INFORMATION ON SUCH DISCLOSURES AND LETTERS OF
13、 ASSURANCE, CONTACT ISA OR VISIT WWW.ISA.ORG/STANDARDSPATENTS. OTHER PATENTS OR PATENT CLAIMS MAY EXIST FOR WHICH A DISCLOSURE OR LETTER OF ASSURANCE HAS NOT BEEN RECEIVED. ISA IS NOT RESPONSIBLE FOR IDENTIFYING PATENTS OR PATENT APPLICATIONS FOR WHICH A LICENSE MAY BE REQUIRED, FOR CONDUCTING INQUI
14、RIES INTO THE LEGAL VALIDITY OR SCOPE OF PATENTS, OR DETERMINING WHETHER ANY LICENSING TERMS OR CONDITIONS PROVIDED IN CONNECTION WITH SUBMISSION OF A LETTER OF ASSURANCE, IF ANY, OR IN ANY LICENSING AGREEMENTS ARE REASONABLE OR NON-DISCRIMINATORY. ISA REQUESTS THAT ANYONE REVIEWING THIS DOCUMENT WH
15、O IS AWARE OF ANY PATENTS THAT MAY IMPACT IMPLEMENTATION OF THE DOCUMENT NOTIFY THE ISA STANDARDS AND PRACTICES DEPARTMENT OF THE PATENT AND ITS OWNER. ANSI/ISA-TR12.21.01-2004 (R2013) 4 Copyright 2013 ISA. All rights reserved. ADDITIONALLY, THE USE OF THIS DOCUMENT MAY INVOLVE HAZARDOUS MATERIALS,
16、OPERATIONS OR EQUIPMENT. THE DOCUMENT CANNOT ANTICIPATE ALL POSSIBLE APPLICATIONS OR ADDRESS ALL POSSIBLE SAFETY ISSUES ASSOCIATED WITH USE IN HAZARDOUS CONDITIONS. THE USER OF THIS DOCUMENT MUST EXERCISE SOUND PROFESSIONAL JUDGMENT CONCERNING ITS USE AND APPLICABILITY UNDER THE USERS PARTICULAR CIR
17、CUMSTANCES. THE USER MUST ALSO CONSIDER THE APPLICABILITY OF ANY GOVERNMENTAL REGULATORY LIMITATIONS AND ESTABLISHED SAFETY AND HEALTH PRACTICES BEFORE IMPLEMENTING THIS DOCUMENT. THE USER OF THIS DOCUMENT SHOULD BE AWARE THAT THIS DOCUMENT MAY BE IMPACTED BY ELECTRONIC SECURITY ISSUES. THE COMMITTE
18、E HAS NOT YET ADDRESSED THE POTENTIAL ISSUES IN THIS VERSION. The following people served as members of ISA Subcommittee ISA12.21 which prepared this technical report: NAME COMPANY P. Kelly, ISA12.21 Chair UL LLC M. Coppler, Managing Director Det Norske Veritas Certification Inc. D. Baker P b) photo
19、chemical ignition due to photodissociation of oxygen molecules by radiation in the ultraviolet region; and c) direct laser induced breakdown of the gas at the focus of a strong beam, producing plasma and a shock wave, both of which acting as ignition sources. These three mechanisms require either re
20、latively high peak powers or ultraviolet radiation n ot commonly found in current practice. Although one should be aware of these other mechanisms, they are not addressed in this technical report. Explosive targets or targets that contain their own oxidizer are also outside the scope of this technic
21、al report. 5.4 Optical beam spatial and temporal characteristics greatly influence ignitability of explosive gas atmospheres. Table 1 summarizes the limiting beam strength parameters for igniting explosive gas atmospheres as a function of beam spatial and temporal characteristics. For a short durati
22、on optical pulse with a small beam diameter, the energy required to cause ignition reaches a minimum. For such a beam, limiting the pulse energy to levels below the minimum optical ignition energy will prevent ignitions, regardless of the peak power, peak power density, or energy density. Similar re
23、lationships apply to the other combinations of beam diameter and duration. As long as the optical beam does not exceed the limiting beam strength parameter for its particular temporal and spatial domain, the other beam strength parameters need not be considered. Table 1 Limiting beam strength parame
24、ters for igniting explosive gas atmospheres based on beam spatial and temporal characteristics. Short duration (pulsewidth 1 cm) Energy density Power density 19 ANSI/ISA-TR12.21.01-2004 (R2013) Copyright 2013 ISA. All rights reserved. 5.5 Optical ignition powers generally reach a minimum for beam di
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIISATR1221012004USEOFFIBEROPTICSYSTEMSINCLASSIHAZARDOUSCLASSIFIEDLOCATIONSPDF

链接地址:http://www.mydoc123.com/p-437017.html