ANSI ASTM D6096-2011 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable 90 Operation《90℃工作温度下电线和电缆用聚氯乙烯绝缘材料的规范》.pdf
《ANSI ASTM D6096-2011 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable 90 Operation《90℃工作温度下电线和电缆用聚氯乙烯绝缘材料的规范》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM D6096-2011 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable 90 Operation《90℃工作温度下电线和电缆用聚氯乙烯绝缘材料的规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6096 11 (Reapproved 2016)Standard Specification forPoly(Vinyl Chloride) Insulation for Wire and Cable, 90COperation1This standard is issued under the fixed designation D6096; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers a thermoplastic insulation ofpoly (vinyl chloride) or the copolymer of vi
3、nyl chloride andvinyl acetate. This insulation is recommended for use atconductor temperatures not in excess of 90C.1.2 Depending on the thickness of the insulation, the maxi-mum voltage used, and whether the location is wet or dry, thisinsulation is acceptable for use in 300 V (dry) and 600 V (weto
4、r dry) power and control circuits.1.3 This insulation has potential low-temperature installa-tion limitations. Consult the manufacturer for specific recom-mendations for installation.1.4 In many instances, the insulation material cannot betested unless it has been formed around a conductor or cable.
5、Therefore, tests are done on insulated wire or cable in thisspecification solely to determine the relevant property of theinsulation material and not to test the conductor or completedcable.1.5 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are m
6、athematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5.1 In some cases (including the title), temperatures aredescribed in degrees Celsius only.2. Referenced Documents2.1 ASTM Standards:2D1711 Terminology Relating to Electrical InsulationD2633 Te
7、st Methods for Thermoplastic Insulations andJackets for Wire and Cable3. Terminology3.1 Definitions: For definitions of terms used in thisspecification, refer to Terminology D1711.3.2 Definitions of Terms Specific to This Standard:3.2.1 aging (act of), nexposure of materials to air or oil ata temper
8、ature and for an interval of time as required in Table1.4. Physical Properties4.1 The insulation shall conform to the requirements forphysical properties prescribed in Table 1. (See Table 2 foroptional oil resistance requirements.)1This specification is under the jurisdiction of ASTM CommitteeD09 on
9、Electrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.18 on Solid Insulations, Non-Metallic Shieldings and Coveringsfor Electrical and Telecommunication Wires and Cables.Current edition approved Feb. 1, 2016. Published February 2016. Originallyapproved in
10、 1997. Last previous edition approved in 2011 as D6096 11. DOI:10.1520/D6096-11R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary pa
11、ge onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Electrical Requirements5.1 Perform the ac voltage, insulation resistance, and dcvoltage tests in
12、 that order when any of these tests are required.The sequence for other testing is not specified.5.2 AC Voltage Test Test the insulated conductor at the acwithstand voltage as specified in Table 3. Unless otherwisespecified, omit this test if the dc withstand voltage testdescribed in 5.4 is performe
13、d.5.2.1 For cables or conditions of service where mechanicalstresses govern, such as in submarine cables or long verticalrisers, it is possible that the minimum conductor sizes in Table3 are not strong enough.5.2.2 The thicknesses given in Table 3 apply to aerial cablesand to single conductors insta
14、lled in conduits above ground andto the individual conductors of all multiple-conductor cableshaving a common jacket, metallic sheath, or protective cover-ing over the assembly, excerpt as shown in 5.2.2.1.5.2.2.1 For single-conductor cables for installation in under-ground ducts or direct earth bur
15、ial and for all submarine cables,add 15 mil (0.38 mm) to the insulation thicknesses given inTable 3, when such cables do not have a thermoplastic jacketor metallic sheath over the assembly.5.2.3 Where the thickness of the insulation is increased formechanical reasons or for special service condition
16、s, determinethe test voltage in Table 3 by the size of the conductor and therated voltage.5.3 Insulation Resistance:5.3.1 Insulated conductors in SizesAWG 14 (2.08 mm2) andlarger shall have an insulation resistance of at least thatcorresponding to a constant of 2000 M-1000 ft at 60F(15.6C).5.3.2 If
17、the temperature at the time the measurement wasmade differs from 60F (15.6C), correct the insulation resis-tance to 60F by multiplying the measured value by the propercorrection factor from Table number 1 of Test Methods D2633.5.4 DC Voltage Test Upon completion of the insulationresistance test, tes
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD60962011STANDARDSPECIFICATIONFORPOLYVINYLCHLORIDEINSULATIONFORWIREANDCABLE90OPERATION90 工作温度

链接地址:http://www.mydoc123.com/p-432437.html