1、Standard Specification for Weighing Devices Used in the Testing of Materials AASHTO Designation: M 231-95 (2015) American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001 TS-1b M 231-1 AASHTO Standard Specification for Weighing
2、 Devices Used in the Testing of Materials AASHTO Designation: M 231-95 (2015) 1. SCOPE 1.1. This specification covers requirements for scales and balances, and the loose standard masses used with balances, used in the testing of construction materials. 1.2. The requirements included are descriptive
3、of the balances required by a number of AASHTO test methods. The general-purpose balances described herein may not be sufficiently accurate for certain tests, especially where a high degree of accuracy is required at large capacities. In such instances, the requirements for the balance should be inc
4、luded in the test method. 1.3. The requirements included herein are not sufficiently descriptive to be used as purchase specifications without amplification by the potential purchaser. 1.4. The values stated in SI units are to be regarded as the standard. 2. REFERENCED DOCUMENTS 2.1. ASTM Standard:
5、E617, Standard Specification for Laboratory Weights and Precision Mass Standards 2.2. National Institute of Standards and Technology: NIST Handbook 44 (1992 Edition) 3. CLASSIFICATION 3.1. Weighing devices are divided into two classes of analytical balances, designated A and B, and five classes of g
6、eneral-purpose scales or balances, designated G1, G2, G5, G20, and G100, based on readability. 3.2. Standard masses classified as Class 1, 2, 3, and 4, listed in ASTM E617, Standard Specification for Laboratory Weights and Precision Mass Standards, may be used with the analytical balances. Standard
7、masses listed in Table 2, Section 2.23 of NIST Handbook 44 (1992 Edition) may be used with general-purpose balances. 4. TERMINOLOGY 4.1. acceptance tolerancethe maximum permissible deviation from correct indication for new standard masses or balances and for standard masses or balances having receiv
8、ed major servicing. Usually equal to one half of the maintenance tolerance. 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-1b M 231-2 AASHTO 4.2. accuracymaximum permissible deviation of indications
9、of a balance or scale from the true value within applicable tolerances. 4.3. balancean instrument for determining mass, in its simplest form having a beam supported exactly in the middle and having two pans of equal mass suspended from its extremities. Generally, weighing devices of a relatively hig
10、h degree of accuracy used for determinations of mass in the laboratory. 4.4. direct-reading balancea balance on which the mass of applied loads of various magnitudes is either automatically indicated, or is indicated by means of a calibrated weighbeam, throughout all or a portion of the range of the
11、 balance. 4.5. equal-arm balancea balance having a beam supported exactly in the middle, having two pans suspended from its extremities, in which the mass of unknown quantity on one pan is compared with a set of standards of mass in the other pan. There may or may not be a weighbeam. 4.6. general-pu
12、rpose massesstandard masses used for general mass determination, generally being less accurate than standard analytical masses. 4.7. maintenance tolerancemaximum permissible deviation from correct indication for masses or balances in service. 4.8. off-center loadingapplication of a load to the pan o
13、f a balance or scale at a point displaced from the center of the support axis of the load-receiving element. 4.9. readabilitythe smallest unit of mass that can be read without estimation over the given range of measurement either directly or by use of a vernier or micrometer. 4.10. scalean instrumen
14、t or machine used for mass determination, usually embodying a system of multiplying levers. Generally considered to have a lesser degree of accuracy than balances. 4.11. sensitivitymass required to produce a discernible movement in the indicating system of the balance or scale. 4.12. sensitivity req
15、uirementthe minimum change in the position of rest of the indicating element of a scale or balance in response to a specified change in test load on the load-receiving element of the scale or balance. 4.13. simple balancea balance designed primarily for use in conjunction with a set of standard mass
16、es. There may or may not be a weighbeam. 4.14. standard analytical massesworking standards of mass used for analytical work, having relatively small tolerances from the stated values. 5. REQUIREMENTS 5.1. Analytical BalancesAnalytical balances of the class specified shall conform to the requirements
17、 of Table 1. These requirements apply both to balances with built-in masses and balances used with separate masses. The class for standard masses is suggested to provide the required accuracy (Note 1). 2015 by the American Association of State Highway and Transportation Officials.All rights reserved
18、. Duplication is a violation of applicable law.TS-1b M 231-3 AASHTO Table 1Standard Analytical Balances Balance Class Accuracy Sensitivity ReadabilityaClass of Standard MassesbCapacitycA 0.0002 g 0.0001 g 0.0001 g 1, 2, or 3 200 g B 0.002 g 0.001 g 0.001 g 3 200 g aReadability of markings on direct
19、reading balances. bClass suggested for use with simple balances. cMaximum capacity generally available with balances of the accuracy and sensitivity indicated for the class. Varies depending on the manufacturer, and whether direct reading or simple balance. Note 1The tolerances for standard masses a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOM2311995STANDARDSPECIFICATIONFORWEIGHINGDEVICESUSEDINTHETESTINGOFMATERIALS 材料 试验 称重 装置 标准规范 PDF

链接地址:http://www.mydoc123.com/p-417724.html