ISO TR 12468-3-2014 External exposure of roofs to fire - Part 3 Commentary《屋顶外露部分的防火 第3部分 注释》.pdf
《ISO TR 12468-3-2014 External exposure of roofs to fire - Part 3 Commentary《屋顶外露部分的防火 第3部分 注释》.pdf》由会员分享,可在线阅读,更多相关《ISO TR 12468-3-2014 External exposure of roofs to fire - Part 3 Commentary《屋顶外露部分的防火 第3部分 注释》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、 ISO 2014 External exposure of roofs to fire Part 3: Commentary Exposition des toitures un feu extrieur Partie 3: Commentaire TECHNICAL REPORT ISO/TR 12468-3 First edition 2014-08-15 Reference number ISO/TR 12468-3:2014(E) ISO/TR 12468-3:2014(E)ii ISO 2014 All rights reserved COPYRIGHT PROTECTED DOC
2、UMENT ISO 2014 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission c
3、an be requested from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ISO/TR 12468-3:2014(E) ISO 20
4、14 All rights reserved iii Contents Page Foreword iv Introduction v 1 Scope . 1 2 Normative references 1 3 ISO 12468-1, test method 1 4 Fire scenarios . 1 5 Evaluation parameters . 5 6 ISO 124682, classification of roofs. 6 Bibliography 7 ISO/TR 12468-3:2014(E) Foreword ISO (the International Organi
5、zation for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been establishe
6、d has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
7、The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the
8、 editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any paten
9、t rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents). Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement. For
10、an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the WTO principles in the Technical Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information The committee responsible for t
11、his document is ISO/TC 92, Fire safety, Subcommittee SC 2, Fire containment. ISO 12468 consists of the following parts, under the general title External exposure of roofs to fire: Part 1: Test method Part 2: Classification of roofs Part 3: Commentaryiv ISO 2014 All rights reserved ISO/TR 12468-3:201
12、4(E) Introduction This part of ISO 12468 describes the background used in the development and ongoing revision of ISO 12468-1:2013 and ISO 12468-2. Guidance is provided on the use of the test method and classification methods. ISO 2014 All rights reserved v External exposure of roofs to fire Part 3:
13、 Commentary 1 Scope This part of ISO 12468 provides background and guidance on the use and limitations of the external fire exposure to roofs test method, the classification system, and the application of the data obtained. This part of ISO 12468 is designed to be of assistance to code officials, fi
14、re safety engineers, designers of buildings, and other persons responsible for the safety of persons in and around buildings. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated referenc
15、es, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 12468-1:2013, External exposure of roofs to fire Part 1: Test method 3 ISO 12468-1, test method In the development of the test method, an attempt was made
16、 to evaluate as many of the potential sources of external fire exposure a roof system could be subjected to as possible. Once identified, the test method attempted to define tests that simulated the identified possible exposure conditions, while at the same time, utilizing tests that already exist a
17、nd are described in national test methods. The ultimate goal of the test method development was to create an international test procedure which incorporated the most desirable elements of the existing test methods that could be used in national regulations and replace the wide variety of test method
18、s that exist in national regulations. The following are the three levels of fire exposure for roofs defined in ISO 124681:2013: Level A: A large burning brand falling onto the roof from an adjacent building. Level A considers the effect of wind and radiant heat. Level B: A medium burning brand comin
19、g from a fire in a neighbourhood and falling onto the roof. Level B considers the effect of wind but without additional radiant heat. Level C: A small burning brand transported by the wind from a remote fire and falling onto the roof. Level C considers the effect of the wind but without additional r
20、adiant heat. The following presentation starts with a summary background description of some fire scenarios, relevant for test methods regarding external fire exposure to roofs. Then the decisive evaluation parameters for different classification systems, based on test measurements and observations,
21、 are identified. 4 Fire scenarios Figures 1 to 6 show different types of external fire exposure to a roof. TECHNICAL REPORT ISO/TR 12468-3:2014(E) ISO 2014 All rights reserved 1 ISO/TR 12468-3:2014(E) Figure 1 Flying brand from a remote building or from environmental vegetation Figure 2 Radiation ex
22、posure from a fire in a nearby building Figure 3 Direct flame exposure together with radiation exposure from a fire in a nearby building in a dense small house area2 ISO 2014 All rights reserved ISO/TR 12468-3:2014(E) Figure 4 Combined exposure by flying brand and radiation from a nearby building Fi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISOTR1246832014EXTERNALEXPOSUREOFROOFSTOFIREPART3COMMENTARY 屋顶 外露 部分 防火 注释 PDF

链接地址:http://www.mydoc123.com/p-1257601.html