ISO 814-2011 Rubber vulcanized or thermoplastic - Determination of adhesion to metal - Two-plate method《硫化橡胶或热塑性橡胶 金属附着力测定 双板法》.pdf
《ISO 814-2011 Rubber vulcanized or thermoplastic - Determination of adhesion to metal - Two-plate method《硫化橡胶或热塑性橡胶 金属附着力测定 双板法》.pdf》由会员分享,可在线阅读,更多相关《ISO 814-2011 Rubber vulcanized or thermoplastic - Determination of adhesion to metal - Two-plate method《硫化橡胶或热塑性橡胶 金属附着力测定 双板法》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 Reference numberISO 814:2011(E)ISO 2011INTERNATIONAL STANDARD ISO814Fifth edition2011-11-15Rubber, vulcanized or thermoplastic Determination of adhesion to metal Two-plate method Caoutchouc vulcanis ou thermoplastique Dtermination de ladhrence au mtal Mthode deux plaques ISO 814:2011(E) COPYRIGHT P
2、ROTECTED DOCUMENT ISO 2011 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO
3、s member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2011 All rights reservedISO 814:2011(E) ISO 2011 All rights reserved iiiContents
4、Page Foreword iv 1 Scope 1 2 Normative references 1 3 Principle . 1 4 Apparatus . 2 5 Calibration 2 6 Test piece . 2 6.1 Dimensions 2 6.2 Preparation . 2 6.3 Number . 3 6.4 Conditioning 4 7 Procedure . 4 8 Expression of results 4 8.1 Adhesion value 4 8.2 Adhesion failure symbols . 4 9 Test report 5
5、Annex A (normative) Calibration schedule 6 A.1 Inspection . 6 A.2 Schedule . 6 ISO 814:2011(E) iv ISO 2011 All rights reservedForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing Internatio
6、nal Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO
7、, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical com
8、mittees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the
9、possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 814 was prepared by Technical Committee ISO/TC 45, Rubber and rubber products, Subcommittee SC 2, Testing and analysis. Thi
10、s fifth edition cancels and replaces the fourth edition (ISO 814:2007), of which it constitutes a minor revision to include an annex specifying a calibration schedule for the apparatus used. INTERNATIONAL STANDARD ISO 814:2011(E) ISO 2011 All rights reserved 1Rubber, vulcanized or thermoplastic Dete
11、rmination of adhesion to metal Two-plate method WARNING Persons using this International Standard should be familiar with normal laboratory practice. This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to establi
12、sh appropriate safety and health practices and to ensure compliance with any national regulatory conditions. IMPORTANT Certain procedures specified in this International Standard might involve the use or generation of substances, or the generation of waste, that could constitute a local environmenta
13、l hazard. Reference should be made to appropriate documentation on safe handling and disposal after use. 1 Scope This International Standard specifies a method for determining the adhesion strength of rubber-to-metal bonds where the rubber part is assembled between two parallel metal plates, using t
14、he adhesive system under investigation. The method is applicable primarily to test pieces, prepared in the laboratory under standard conditions, such as can be used to provide data for the development of rubber compounds and control of methods of manufacture. 2 Normative references The following ref
15、erenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 5893, Rubber and plastics test equipment Tensile, flexural and
16、 compression types (constant rate of traverse) Specification ISO 18899:2004, Rubber Guide to the calibration of test equipment ISO 23529, Rubber General procedures for preparing and conditioning test pieces for physical test methods 3 Principle The test consists in measuring the force required to ca
17、use the rupture of a unit of standard dimensions, comprising rubber bonded to two parallel metal plates, the direction of the force being at 90 to the bonded surface. ISO 814:2011(E) 2 ISO 2011 All rights reserved4 Apparatus 4.1 Tensile-testing machine, complying with the requirements of ISO 5893, c
18、apable of measuring force with an accuracy corresponding to class 2 as defined in ISO 5893, and with a rate of traverse of the moving grip of 25 mm/min 5 mm/min. NOTE Inertia (pendulum) type dynamometers are apt to give results which differ because of frictional and inertial effects. An inertialess
19、(for example, electronic or optical transducer) type dynamometer gives results which are free from these effects and is therefore preferred. 4.2 Fixtures, for holding the test pieces in the test machine (4.1), which permit accurate centring of the applied load during the test. A suitable type of fix
20、ture is shown in Figure 1. 5 Calibration The test apparatus shall be calibrated in accordance with Annex A. 6 Test piece 6.1 Dimensions The standard test piece shall consist of a rubber cylinder 3 mm 0,1 mm thick and of diameter between 35 mm and 40 mm known to the nearest 0,1 mm, having its circula
21、r ends bonded to the faces of two metal plates of equal diameter, the determination of dimensions of the test piece being in accordance with ISO 23529. The diameter of the metal plates shall be approximately 0,1 mm less than that of the rubber cylinder. The thickness of the metal plates shall be not
22、 less than 9 mm. A typical test piece is shown in Figure 2. 6.2 Preparation 6.2.1 Circular metal plates of the standard dimensions shall be prepared preferably from rolled carbon steel bar. Other metals may be used provided that the parts are in conformity with the essential dimensions. The smooth m
23、etal parts shall be prepared and treated in accordance with the adhesion system under investigation. 6.2.2 Rubber discs shall be cut using a circular die of such size that a limited amount of flash is obtained on moulding. The surface of the rubber to be bonded to the metal shall be treated in accor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO8142011RUBBERVULCANIZEDORTHERMOPLASTICDETERMINATIONOFADHESIONTOMETALTWOPLATEMETHOD 硫化橡胶 塑性 橡胶 金属 附着力

链接地址:http://www.mydoc123.com/p-1255784.html