ISO 10849-1996 Stationary source emissions - Determination of the mass concentration of nitrogen oxides - Performance characteristics of automated measuring sys.pdf
《ISO 10849-1996 Stationary source emissions - Determination of the mass concentration of nitrogen oxides - Performance characteristics of automated measuring sys.pdf》由会员分享,可在线阅读,更多相关《ISO 10849-1996 Stationary source emissions - Determination of the mass concentration of nitrogen oxides - Performance characteristics of automated measuring sys.pdf(23页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL STANDARD IS0 10849 First edition 1996-04-I 5 Stationary source emissions - Determination of the mass concentration of nitrogen oxides - Performance characteristics of automated measuring systems gmissions de sources fixes - D - non-dispersive ultraviolet spectroscopy; - differential op
2、tical absorption spectrometry. NOTE 1 Commercial devices using the described tech- niques, that meet the requirements of this International Standard, are available. 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this
3、International Standard. At the time of publi- cation, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most re- cent editions of the standards indicat
4、ed below. Members of IEC and IS0 maintain registers of cur- rently valid International Standards. IS0 6879:1995, Air quality - Performance character- istics and related concepts for air quality measuring methods. IS0 7996: 1985, Ambient air - Determination of the mass concentration of nitrogen oxide
5、s - Chemiluminescence method. IS0 9096: 1992, Stationary source emissions - De- termination of concentration and mass flow rate of particulate material in gas-carrying ducts - Manual gravimetric method. IS0 9169:1994, Air quality - Determination of per- formance characteristics of measurement method
6、s. IS0 10396:1993, Stationary source emissions - Sampling for the automated determination of gas concentrations. 3 Definitions For the purposes of this International Standard, the following definitions apply. 3.1 automated measuring system (AMS): System that may be attached to a chimney to continuou
7、sly measure and record the mass concentration of nitro- gen oxides passing through the chimney. 3.2 analyser: Analytical part in an extractive AMS. 1 IS0 10849:1996(E) 0 IS0 3.3 verified (AMS): AMS previously verified against - the mass concentration of nitrogen oxides in waste gas this Internationa
8、l Standard. usually varies with time; 3.4 calibration gas: Gas of known, reliable and sta- ble composition that may be used to check the re- sponse of the AMS and should be used for the calibration of the AMS. 3.5 comparative measurements: Measurements that are taken on the same chimney in the same
9、sampling plane for the same period of time, with the AMS under test and with the comparative method providing pairs of measured values. 3.6 comparative method: Defined test method for the comparative measurements of stationary source emissions containing nitrogen oxides. This can be a manual method
10、or an AMS verified according to this International Standard, with a different measuring principle. NOTE 2 The naphthylethylenediamine (NEDA) method according to IS0 11564, has been proven to be a suitable manual method. Also, validated national standards with known performance characteristics (stand
11、ard deviation, lower detection limit, effect of interfering substances) may be applied. 3.7 standard deviation, sa: Measure of the working precision of the AMS. The standard deviation, SA, is derived from the differ- ence in the pairs of measured values of nitrogen ox- ides by the AMS under test and
12、 the comparative method, on the basis of a sufficient number of com- parative measurements spread over the period of un- attended operation (see annex A). % is the standard deviation of the compara- tive method. SD is the standard deviation of the paired val- ues. SX is the standard deviation of the
13、 blank readings. NOTES 3 It is not possible to determine directly the standard de- viation, s, of an AMS under repeatable working conditions or in a laboratory, because: - commercially available calibration gas mixtures contain- ing nitrogen monoxide do not have all the properties of actual waste ga
14、s and do not cover all possible influ- ences; - it is not possible to maintain the properties of a waste gas present in the waste gas flue in a waste gas sample transferred into a vessel. Therefore, the evaluation of the standard deviation, s, is performed by comparison with an independent manual me
15、thod or an analyser with a different principle of detection. Applying the comparative method in combination with the test for systematic errors ensures a satisfying accuracy of the automated measuring system. 4 The standard deviation, s, is a measure of the working precision under site conditions. T
16、herefore, it contains, in addition to random errors, the effects of interfering sub- stances, the effects of temperature changes and of any zero and span drifts, because they cannot be eliminated in prac- tice. The standard deviation, s, is an upper limiting value for the AMS. Known systematic error
17、s of the measured values of the independent comparative method are to be taken into account. 5 This procedure is suitable for finding the precision of the measuring result of the automated measuring method, as long as the standard deviation, s, of the measured values of the comparative method is sig
18、nificantly smaller than the standard deviation, s, of the difference in pairs of measured values. If the AMS under investigation has a substantially smaller standard deviation, s, than the comparative method, s, the method above can still be used, although the value of s, will have a large uncertain
19、ty. If the uncertainty in s, is un- known and hence the limits of S, cannot be established, the value of s, can be used as a qualitative rather than a quan- titative assessment of the AMS performance. 3.8 chimney: Stack or final exit duct on a stationary process used for the dispersion of residual p
20、rocess gases. 3.9 mass concentration: Concentration of a sub- stance in an emitted waste gas, expressed in milli- grams per cubic metre. NOTE 6 The concentration of nitrogen oxides can be ex- pressed as ppm, as milligrams of NO per cubic metre or as milligrams of NO, per cubic metre. NO: 1 ppm (V/V)
21、 = 1.34 mg/m3 NO,: 1 ppm (V/V) = 2.05 mg/m3 Concentrations should be related to standard atmospheric conditions (273 K, 101.3 kPa) and dry gas. Depending on national regulations, the concentrations should be referred to defined oxygen or carbon dioxide concentrations. 2 SO 10849:1996(E) In this Inte
22、rnational Standard, all concentrations of nitrogen oxides are expressed as milligrams of NO, per cubic metre. 3.10 stationary source emissions: Those gases that have been emitted by a stationry plant or process and are transported to a chimney for dispersion into the atmosphere. 3.11 calibration cur
23、ve: Curve describing the de- pendence of the measured signal on a given cali- bration gas. 3.12 period of unattended operation: Maximum admissible interval of time for which the performance characteristics will remain within a predefined range without external servicing, e.g. refill, calibration, ad
24、- justment. ISO 68791 NOTE 7 For long-term monitoring installations a mini- mum of 7 d of unattended operation is required. 3.13 calibration: Setting and checking of the AMS before determining the performance characteristics or before beginning any measurement of NO,. Further steps of the calibratio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO108491996STATIONARYSOURCEEMISSIONSDETERMINATIONOFTHEMASSCONCENTRATIONOFNITROGENOXIDESPERFORMANCECHARACTERISTICSOFAUTOMATEDMEASURINGSYSPDF

链接地址:http://www.mydoc123.com/p-1249915.html