1、 flIL-C-22b67B bL 7797706 0088320 L W MIL-C -22667B( SHIPS) 11 May 1966 SUPERSEDING MIL-C - 22667A( SHIPS) 21 November 1961 MILITARY SPECIFICATION CABLE, SPECIAL PURPOSE, BUOYANT, ELECTRICAL, TYPE RG-298/U (SUBMARINE USE) 1. SCOPE 1.1 This specification covers special single-conductor buoyant cable
2、with high mechanical performance characteristics, such as high strength, flexibility, low compression set, low water absorption, low tempera- ture properties and abrasion resistance. # 2. APPLICABLE DOCUMENTS 2. 1 The following documents, of the issue in effect on date of invitation for bids or requ
3、est for proposal, form a part of this specification to the extent specified herein: SPECIFIC ATIONS FEDERAL L-P-390 - Plastic Molding Material, Polyethylene, Low and Medium Intensity. QQ-W-345 - Wire, Electrical, Steel, Copper Covered. MILITARY MIL-(2-17 - Cables, Radio Frequency; Coaxial, Dual Coax
4、ial, Twin Conductor, and Twin Lead. (Copies o specifications, standards, drawings, and publications required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contract- ing officer. ) 2. 2 Other publications. - The fol
5、lowing document forms a part of this specification to the extent specified herein. Unless otherwise indicated, the issue in effect on date of invitation for bids or request for proposal shall apply. OFFICIAL CLASSIFICATION COMMITTEE Uniform Freight Classification Ratings, Rules, and Regulations (App
6、lication for copies should be addressed to the Official Classification Committee, 1 Park Avenue at 33rd Street, New York 16, N. Y. ) 3. REQUIREMENTS 3.1 Preproduction sample. - A preproduction sample shall be furnished for the inspection speciied in 4.2 (see 6.2). 3. 2 Materials and construction. -
7、3. 2.1 Center conductor. - The center conductor of the cable shall be stranded in accordance with # MIL-C-17. The conductor shall consist of seven strands of No. 24 AWG, high-strength, copper-covered (electroplated) wires, 30 2 percent conductivity, conforming to QQ-W-345. class L, grade 7 (natural)
8、 or 7a (colors) of L-P-390, having an outside diameter of O. 115 2 O. 004 inch. 3. 2. 2 Solid core dielectric. - The solid core dielectric shall be polyethylene in accordance with type II, . THIS DQGUMIENT CONTAINS PAGES Provided by IHSNot for ResaleNo reproduction or networking permitted without li
9、cense from IHS-,-,-flIL-C-2i?bb7B b1 4Ob 0088321 3 MIL-C- 22667B(SHIPS) # 3.2.3 Jacket. - The jacket shall consist of two layers of continuous, homogeneous unicellular black foamed polyethylene. Minimum thickness of individual layers shall be O. 120 inch. The extreme outside diameter of the cable sh
10、all be O. 650 5 O. 025 inch. The outer layer of the jacket shall be of uniform hard- ness, and shall be free of major imperfections such as blow holes, cuts, valleys, and bruises. The jacket shall be manufactured from material which meets the requirements of type I, class L, grade 2 of L-P-390. 3.3
11、Breaking strength, - The center conductor of the cable shall have a minimum breaking strength of 400 pounds, 3.4 Shear strength, - 3.4.1 Between center conductor and solid core dielectric. - The shear strength between the center 3.4.2 Between solid core dielectric and inner or outer layer of jacket.
12、 - The shear strength between conductor and solid core dielectric shall be a minimum of 50 pounds per linear foot of cable. the solid core dielectric and the inner or outer layer of the jacket shall be a minimum of 50 pounds per linear foot of cable, 3.5 Specific gravity. - The cable shall have the
13、lowest possible overall specific gravity consistent with the requirements specified herein, The specific gravity shall not exceed O. 80 when tested as specified in 4.4.5. 3.6 Cold bend. - There shall be no evidence of cracks or flaws in either the dielectric material or the jacket, when tested .as s
14、pecified in 4,4.6. 3.7 Crack resistance. - The cable shall be resistant to stress cracking, when tested as specified in 4.4.7. 3,8 Bonding. - Bonding shall be accomplished by the proper appllcation of heat. The bond between the solid core dielectric and inner layer shall be non-continuous in such ma
15、nner that the jacket will be easily strippable in certain areas to effect an “O“ ring seat on the inner core dielectric without any additional preparation, These strippable areas shall be not less than 2 inches long in any linear foot of cable. The bond between the jacket layers shall be continuous
16、and construction shall not impair the strength requirements of 3.4. 3.9 Length, - Unless otherwise specified (see 6.1) cable shall be provided in not less than 2,000-foot 3.10 Marking, - 3,lO.l Manufacturers identification. - Manufacturers identification shall consist of coloring the solid a nor mor
17、e than 2,100-foot continuous (with no joint or splice) lengths. # dielectric core in accordance with a manufacturers identification color to be assigned by the bureau or agency concerned. Coloring of the core shall not affect the characteristics of the cable. There shall be no markings on the outer
18、surface of the cable, 3.10.2 Reel marking. - All reels shall be marked with cable designation, contract, date of manufacture, manufacturer, and lengths of cable. 3.11 Workmanship. - The workmanship shall be first class in every respect and uniform throughout each lot of cable offered for delivery. 4
19、, QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection, - Unless otherwise specified in the contract or purchase order, the supplier is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified, the supplier may utilize his own facili
20、ties or any commercial laboratory acceptable to the Government. The Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements, # Provided by IHSNot for
21、ResaleNo reproduction or networking permitted without license from IHS-,-,-.t MIL-C-22667B 61 W 9779706 0088322 5 W MIL-C - 22667B( SHIPS) # 4.1.1 Quality control system. - The supplier shall provide and maintain a quality control system which meets the requirements specified in the appendix. # 4.2
22、Preproduction inspection. - A 300-foot sample of cable constructed in accordance with this specification shall be subjected to the examination and tests specified in 4. 3. 2 and 4.4, # 4.2.1 Preproduction test report. - A report of the tests conducted shall be forwarded to the Bureau of Ships and th
23、e contracting officer. The manufacturer shall not initiate production prior to receipt of approval of this report except at his own risk. # 4.3 Quality conformance inspection. - . # 4,3,1 Sampling. - A 10-foot sample of cable shall be selected from every production run for the examination and tests
24、of 4. 3. 2, 4.4. 1, 4.4. 2, 4.4. 3, 4.4.4, and 4.4.5. Samples of sufficient length shall be selected from every 40,000 feet of cable for the tests of 4.4.6 and 4.4.7. 4.3,2 Visual and dimensional examination. - The samples selected in accordance with 4.3.1 shall be examined to verify that the design
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILC22667B1966CABLESPECIALPURPOSEBUOYANTELECTRICALTYPERG298USUBMARINEUSE 潜艇 RG 198 专门 用途 电动 浮力 缆索

链接地址:http://www.mydoc123.com/p-977538.html