IEEE 1810-2017 en IEEE Guide for the Installation of Fire-Rated Cables Suitable for Hydrocarbon Pool Fires for Critical and Emergency Shutdown Systems in Petrol.pdf
《IEEE 1810-2017 en IEEE Guide for the Installation of Fire-Rated Cables Suitable for Hydrocarbon Pool Fires for Critical and Emergency Shutdown Systems in Petrol.pdf》由会员分享,可在线阅读,更多相关《IEEE 1810-2017 en IEEE Guide for the Installation of Fire-Rated Cables Suitable for Hydrocarbon Pool Fires for Critical and Emergency Shutdown Systems in Petrol.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、IEEE Guide for the Installation of Fire-Rated Cables Suitable for Hydrocarbon Pool Fires for Critical and Emergency Shutdown Systems in Petroleum and Chemical Industries IEEE Std 1810-2017 IEEE Power and Energy Society Sponsored by the Insulated Conductors Committee and the IEEE Industry Application
2、s Society Sponsored by the Petroleum and Chemical Industry Committee IEEE 3 Park Avenue New York, NY 10016-5997 USAIEEE Std 1810-2017 IEEE Guide for the Installation of Fire-Rated Cables Suitable for Hydrocarbon Pool Fires for Critical and Emergency Shutdown Systems in Petroleum and Chemical Industr
3、ies Sponsor Insulated Conductors Committee and Petroleum and Chemical Industry Committee of the IEEE Power and Energy Society and IEEE Industry Applications Society Approved 23 March 2017 IEEE-SA Standards BoardAbstract: Information on the installation of fire-rated, power, control, and instrumentat
4、ion cables suitable for hydrocarbon pool fires, as typically used in petroleum, chemical, and similar plants, offshore marine platforms, in emergency and safety shutdown systems are provided in this instal- lation guide. Keywords: cable, circuit integrity, conductor, emergency isolation valves, emer
5、gency shutdown, fire rated cable system(FRCS), fire-safe, furnace, hydrocarbon pool fire, hydrocarbons, IEEE 1810 mineral insulated cables (MI), motor operated valves (MOV), Polymeric fire rated cable, safety shutdown systems, shake and bake, wire The Institute of Electrical and Electronics Engineer
6、s, Inc. 3 Park Avenue, New York, NY 10016-5997, USA Copyright 2017 by The Institute of Electrical and Electronics Engineers, Inc. All rights reserved. Published 28 September 2017. Printed in the United States of America. IEEE is a registered trademark in the U.S. Patent fitness for a particular purp
7、ose; non-infringement; and quality, accuracy, effectiveness, currency, or completeness of material. In addition, IEEE disclaims any and all conditions relating to: results; and workmanlike effort. IEEE standards documents are supplied “AS IS” and “WITH ALL FAULTS.” Use of an IEEE standard is wholly
8、voluntary. The existence of an IEEE standard does not imply that there are no other ways to produce, test, measure, purchase, market, or provide other goods and services related to the scope of the IEEE standard. Furthermore, the viewpoint expressed at the time a standard is approved and issued is s
9、ubject to change brought about through developments in the state of the art and comments received from users of the standard. In publishing and making its standards available, IEEE is not suggesting or rendering professional or other services for, or on behalf of, any person or entity nor is IEEE un
10、dertaking to perform any duty owed by any other person or entity to another. Any person utilizing any IEEE Standards document, should rely upon his or her own independent judgment in the exercise of reasonable care in any given circumstances or, as appropri- ate, seek the advice of a competent profe
11、ssional in determining the appropriateness of a given IEEE standard. IN NO EVENT SHALL IEEE BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY , OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO: PROCURE- MENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR B
12、USINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY , WHETHER IN CON- TRACT, STRICT LIABILITY , OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE PUBLICATION, USE OF, OR RELIANCE UPON ANY STANDARD, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE AND REGARDLE
13、SS OF WHETHER SUCH DAMAGE WAS FORESEEABLE.4 Copyright 2017 IEEE. All rights reserved. Translations The IEEE consensus development process involves the review of documents in English only. In the event that an IEEE standard is translated, only the English version published by IEEE should be considere
14、d the approved IEEE standard. Official statements A statement, written or oral, that is not processed in accordance with the IEEE-SA Standards Board Operations Manual shall not be considered or inferred to be the official position of IEEE or any of its committees and shall not be considered to be, o
15、r be relied upon as, a formal position of IEEE. At lectures, symposia, seminars, or educational courses, an individual presenting information on IEEE standards shall make it clear that his or her views should be considered the personal views of that individual rather than the formal position of IEEE
16、. Comments on standards Comments for revision of IEEE Standards documents are welcome from any interested party, regardless of membership affiliation with IEEE. However, IEEE does not provide consulting information or advice pertain- ing to IEEE Standards documents. Suggestions for changes in docume
17、nts should be in the form of a proposed change of text, together with appropriate supporting comments. Since IEEE standards represent a consensus of concerned interests, it is important that any responses to comments and questions also receive the concur- rence of a balance of interests. For this re
18、ason, IEEE and the members of its societies and Standards Coordi- nating Committees are not able to provide an instant response to comments or questions except in those cases where the matter has previously been addressed. For the same reason, IEEE does not respond to interpretation requests. Any pe
19、rson who would like to participate in revisions to an IEEE standard is welcome to join the relevant IEEE working group. Comments on standards should be submitted to the following address: Secretary, IEEE-SA Standards Board 445 Hoes Lane Piscataway, NJ 08854 USA Laws and regulations Users of IEEE Sta
20、ndards documents should consult all applicable laws and regulations. Compliance with the provisions of any IEEE Standards document does not imply compliance to any applicable regulatory require- ments. Implementers of the standard are responsible for observing or referring to the applicable regulato
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEE18102017ENIEEEGUIDEFORTHEINSTALLATIONOFFIRERATEDCABLESSUITABLEFORHYDROCARBONPOOLFIRESFORCRITICALANDEMERGENCYSHUTDOWNSYSTEMSINPETROLPDF

链接地址:http://www.mydoc123.com/p-1248483.html