1、12-09 22 05 12 - 1 SECTION 22 05 12 GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION: This section describes the general motor requirements for plumbing equipment. 1.2 RELATED WORK: A. Section 26 05 11, REQUIREMENTS FOR ELECTRICAL INSTALLATIONS: General electrical r
2、equirements common to more than one section of Division 26. B. 26 29 11, LOW-VOLTAGE MOTOR STARTERS: Starters, control and protection of motors: Section C. Section 26 24 19, MOTOR-CONTROL CENTERS: Motor Control Centers. 1.3 SUBMITTALS: A. In accordance with Section 26 05 11, REQUIREMENTS FOR ELECTRI
3、CAL INSTALLATIONS, submit the following: B. Shop Drawings: 1. Sufficient information, clearly presented, shall be included to determine compliance with drawings and specifications. 2. Motor nameplate information shall be submitted including electrical ratings, dimensions, mounting details, materials
4、, horsepower, power factor, current as a function of speed, current efficiency, speed as a function of load, RPM, enclosure, starting characteristics, torque characteristics, code letter, full load and locked rotor current, service factor, and lubrication method. 3. Motor parameters required for the
5、 determination of the Reed Critical Frequency of vertical hollow shaft motors shall be submitted. C. Manuals: 1. Companion copies of complete maintenance and operating manuals, including technical data sheets and application data shall be submitted simultaneously with the shop drawings. D. Certifica
6、tion: Two weeks prior to final inspection, unless otherwise noted, four copies of the following certification shall be submitted to the Resident Engineer: 1. Certification shall be submitted stating that the motors have been properly applied, installed, adjusted, lubricated, and tested. 1.4 APPLICAB
7、LE PUBLICATIONS: A. The publications listed below (including amendments, addenda, revisions, supplements and errata) shall form a part of this Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-12-09 22 05 12 - 2 specification to the extent referenced.
8、Publications are referenced in the text by designation only. B. National Electrical Manufacturers Association (NEMA): MG 1-07 Motors and Generators MG 2-01 Safety Standard and Guide for Selection, Installation and Use of Electric Motors and Generators C. National Fire Protection Association (NFPA):
9、70-08 National Electrical Code (NEC) PART 2 - PRODUCTS 2.1 MOTORS: A. For alternating current, fractional and integral horsepower motors, NEMA Publications MG 1 and MG 2 shall apply. B. Voltage ratings shall be as follows: 1. Single phase: a. Motors connected to 120-volt systems: 115 volts. b. Motor
10、s connected to 208-volt systems: 200 volts. c. Motors connected to 240 volt or 480 volt systems: 230/460 volts, dual connection. 2. Three phase: a. Motors connected to 208-volt systems: 200 volts. b. Motors, less than 74.6 kW (100 HP), connected to 240 volt or 480 volt systems: 230/460 volts, dual c
11、onnection. c. Motors, 74.6 kW (100 HP) or larger, connected to 240-volt systems: 230 volts. d. Motors, 74.6 kW (100 HP) or larger, connected to 480-volt systems: 460 volts. e. Motors connected to high voltage systems: Shall conform to NEMA Standards for connection to the nominal system voltage shown
12、 on the drawings. C. Number of phases shall be as follows: 1. Motors, less than 373 W (1/2 HP): Single phase. 2. Motors, 373 W (1/2 HP) and larger: 3 phase. 3. Exceptions: a. Hermetically sealed motors. b. Motors for equipment assemblies, less than 746 W (1 HP), may be single phase provided the manu
13、facturer of the proposed assemblies cannot supply the assemblies with three phase motors. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-12-09 22 05 12 - 3 D. Horsepower ratings shall be adequate for operating the connected loads continuously in the
14、 prevailing ambient temperatures in areas where the motors are installed, without exceeding the NEMA standard temperature rises for the motor insulation. E. Motor designs, as indicated by the NEMA code letters, shall be coordinated with the connected loads to assure adequate starting and running tor
15、que. F. Motor Enclosures: 1. Shall be the NEMA types shown on the drawings for the motors. 2. Where the types of motor enclosures are not shown on the drawings, they shall be the NEMA types, which are most suitable for the environmental conditions where the motors are being installed. 3. Enclosures
16、shall be primed and finish coated at the factory with manufacturers prime coat and standard finish. 4. All motors in hazardous locations shall be approved for the application and meet the Class and Group as required by the area classification. G. Electrical Design Requirements 1. Motors shall be con
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA2205122009GENERALMOTORREQUIREMENTSFORPLUMBINGEQUIPMENTPDF

链接地址:http://www.mydoc123.com/p-1074864.html