UOP 980-2007 C5 AND LOWER BOILING DIENES OLEFINS AND PARAFFINS IN NAPHTHAS BY GC.pdf
《UOP 980-2007 C5 AND LOWER BOILING DIENES OLEFINS AND PARAFFINS IN NAPHTHAS BY GC.pdf》由会员分享,可在线阅读,更多相关《UOP 980-2007 C5 AND LOWER BOILING DIENES OLEFINS AND PARAFFINS IN NAPHTHAS BY GC.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、 IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO DETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH AND SAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THIS PROCEDURE IN THE MANNER PRESCRIB
2、ED HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS (MSDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSDS) FOR ALL OF THE MATERIALS USED IN THIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTION EQUIPMENT (PPE). COPYRIGHT 2003, 2007 UOP LLC. All rights reserve
3、d. Nonconfidential UOP Methods are available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, USA. The UOP Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service at serviceastm.org, 610.832.9555 FAX, or 610.83
4、2.9585 PHONE. C5and Lower Boiling Dienes, Olefins, and Paraffins in Naphthas by GC UOP Method 980-07 Scope This method is for determining C5and lighter diolefins, mono-olefins, and paraffins in olefinic naphthas. Resolved acetylenes and resolved C6hydrocarbons, including resolved dienes, are also id
5、entified. The method is applicable to selective hydrogenation process feeds, products, and other process streams with similar matrices having a final boiling point of 260C or lower. Components that do not elute from the chromatographic system under the specified conditions, if present in the sample,
6、 are not determined. The lower limit of detection for any compound is 0.01 mass-%. The Appendix describes an extension of the method to analyze LPG samples. References ASTM Method D 4307, “Preparation of Liquid Blends for Use as Analytical Standards,” www.astm.org Scanlon, J. T. and Willis, D. E., J
7、ournal of Chromatographic Science, 23, 333-340 (1985) UOP Method 725, “Pentenes and Lower Boiling Hydrocarbons in Olefinic Gasolines by GC,” www.astm.org UOP Method 999, “Precision Statements in UOP Methods,” www.astm.org Outline of Method The sample to be analyzed is injected into a gas chromatogra
8、ph that is equipped with a fused silica capillary column, internally coated with (bonded) poly-dimethyl siloxane, and a flame ionization detector (FID). The mass-% composition of the sample is obtained by the internal normalization technique, wherein the peak areas are first corrected for difference
9、s in response and then normalized to 100%. Apparatus References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used. Balance, readability 0.1-mg 2 of 15 980-07 Chromatographic column, 100 m of 0.25-mm ID fused silica capillary, internally co
10、ated to a film thickness of 0.5 micron (bonded) with poly-dimethyl siloxane, Petrocol DH, Supelco, Cat. No. 24160-U Gas chromatograph, temperature programmable with cryogenic cooling, built for capillary column chromatography, utilizing a split injection system, equipped with a glass injection port
11、insert, and a flame ionization detector that will give a minimum peak height response of five times the background noise for 0.01 mass-% n-heptane when operated at the recommended conditions, Agilent Technologies, Model 6890. The inclusion of an autosampler (or autoinjector) is recommended but not r
12、equired. Gas purifier, used to remove oxygen from the hydrogen carrier gas, Mat/Sen, Cat. No. P-200-1 Integrator, or data system, electronic, for obtaining peak areas. This device must integrate areas at a sufficiently fast rate so that narrow peaks, typically obtained from a capillary column, can b
13、e accurately measured. The integrator must have programmable parameters for controlling baseline events, and have graphics capabilities. ChemStation, Agilent Technologies. Leak detector, gas, Alltech Associates, Cat. No. 21-250 Refrigerator, flammable-materials storage, Fisher Scientific, Cat. No. 9
14、7-938-1 Regulator, air, two-stage, high purity, Matheson Gas Products, Model 3122-590 Regulator, hydrogen, two-stage, high purity, Matheson Gas Products, Model 3122-350 Regulator, nitrogen or helium, two-stage, high purity, Matheson Gas Products, Model 3122-580 Sample injector, syringe or injector c
15、apable of introducing a 0.5-L volume of sample. An autosampler (or autoinjector) is recommended, Agilent Technologies, Model 7683. Reagents and Materials References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used. Air, zero gas, total hy
16、drocarbons less than 2.0 ppm as methane Autosampler vials, glass, 12 x 32 mm, for Agilent autosampler, Fisher Scientific, Cat. No. 03-391-8 Benzene, 99.9% purity, Aldrich, Cat. No. 27,070-9 Caps, for autosampler vials, open hole with septum, screw, 9 mm, with Tef/Sil/Tef liner, Fisher Scientific, Ca
17、t. No. 03-377-2A Carbon Dioxide, commercial liquid, 99.5% minimum purity, with full-length eductor tube for liquid withdrawal, for cryogenic cooling n-Heptane, 99.9+% purity, Aldrich, Cat. No. 27,051-2 Hydrogen, zero gas, 99.95% minimum purity, total hydrocarbons less than 0.5 ppm as methane Pipet b
18、ulbs, Fisher Scientific, Cat. No. 13-678-9B Pipets, disposable, Pasteur, Fisher Scientific, Cat. No. 13-678-20A Nitrogen or helium, zero gas, total hydrocarbons less than 0.5 ppm as methane Syringe, for sample injector, 5-L, Agilent Technologies, Cat. No. 5181-1273 Toluene, 99.8% purity, Aldrich, Ca
19、t. No. 27,037-7 3 of 15 980-07 p-Xylene, 99+% purity, Aldrich, Cat. No. 31,719-5 Vials, 15-mL, with screw cap, Fisher Scientific, Cat. No. 03-339-21J Procedure Chromatographic Technique The analyst is expected to be familiar with the technique of gas chromatography and the equipment being used. 1. I
20、nstall the gas purifier in the supply line between the carrier gas source and the carrier gas inlets on the gas chromatograph. Column life is significantly reduced if the gas purifier is not used. 2. Install the fused silica capillary column in the gas chromatograph, according to the column and gas
21、chromatograph manufacturers instructions. CAUTION: Hydrogen leakage into the confined volume of the column oven can cause a violent explosion. Therefore, it is mandatory to check for leaks each time a connection is made and periodically thereafter. Table 1 Recommended Operating Conditions Carrier ga
22、s hydrogen Mode constant pressure Head pressure 207 kPa gauge (30 psig) Linear velocity 15C 38 cm/sec Equivalent flow 15C 2.6 mL/min Split flow 200 mL/min Injection port temperature 215C Column temperature program Initial temperature 15C Initial hold time 15 min Programming rate A 8C/min Intermediat
23、e temperature 75C Intermediate hold time 14 min Programming rate B 20C/min Final hold temperature 250C Final hold time 27.5 min Detector flame ionization Detector temperature 250C Hydrogen flow rate* 30 mL/min Air flow rate* 400 mL/min Makeup gas nitrogen or helium Makeup gas flow rate* 30 mL/min Sa
24、mple size 0.5 l *Consult the manufacturers instrument manual for suggested flow rates. 4 of 15 980-07 3. Establish the recommended operating conditions as given in Table 1. Different conditions may be used provided they produce the required sensitivity and chromatographic separations equivalent to t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP9802007C5ANDLOWERBOILINGDIENESOLEFINSANDPARAFFINSINNAPHTHASBYGCPDF

链接地址:http://www.mydoc123.com/p-1074597.html