UOP 962-1998 COPPER IN GASOLINE AND NAPHTHA BY FLAME-AAS OR ICP-AES.pdf
《UOP 962-1998 COPPER IN GASOLINE AND NAPHTHA BY FLAME-AAS OR ICP-AES.pdf》由会员分享,可在线阅读,更多相关《UOP 962-1998 COPPER IN GASOLINE AND NAPHTHA BY FLAME-AAS OR ICP-AES.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、COPPER IN GASOLINE AND NAPHTHABY FLAME-AAS OR ICP-AESUOP Method 962-98SCOPEThis method is for determining trace concentrations of non-volatile, hydrocarbon soluble forms of copperpresent in gasoline, naphtha, kerosene and similar distillates by either Flame-Atomic AbsorptionSpectrometry (Flame-AAS)
2、or Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES). Itis particularly useful on products that have been copper sweetened. The lower limit of quantitation is5g/kg (mass-ppb) copper. The method can be extended to other organic materials and concentrationranges. This method can be use
3、d in place of UOP Method 144.OUTLINE OF METHODThe sample is weighed into a beaker, evaporated to dryness and the residue is ashed in a muffle furnace.The ash is dissolved in hydrochloric and nitric acids and analyzed by either Flame-AAS or ICP-AES, usinga freshly prepared standard and blank.APPARATU
4、SReferences to catalog numbers and suppliers are included as a convenience to the method user. Othersuppliers may be used.Atomic absorption spectrophotometer (Flame-AAS), Perkin-Elmer, Model 3110Balance, top-loading, readability 0.01-gBeaker, Vycor, 250-mL, Fisher Scientific, Cat. No. 02-541ACylinde
5、rs, borosilicate glass, Class B, 10- and 25-mL, Fisher Scientific, Cat. Nos. 08-550B and 08-550C,respectivelyFlasks, volumetric, Pyrex, Class A, 100- and 1000-mL, Fisher Scientific, Cat. Nos. 10-210-5C and 10-210-5G, respectivelyFlask, hexagonal base, 25-mL, Pyrex, Fisher Scientific, Cat. No. 20-814
6、GIT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TODETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH ANDSAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THISPROCEDURE IN THE MANNER PRESCRIBED
7、HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS(MSDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSDS) FOR ALL OF THE MATERIALS USED INTHIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTIONEQUIPMENT (PPE). COPYRIGHT 1998 UOP LLCALL RIGHTS RESERVEDUOP Methods a
8、re available through ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken PA 19428-2959,United States. The Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service atserviceastm.org, 610.832.9555 FAX, or 610.832.9585 PHONE.2 of 6962-98Fun
9、nels, plastic, disposable, 55-mm diameter, Fisher Scientific, Cat. No. 10-320AFurnace, muffle, capable of 500CHollow cathode lamp, copper, Perkin-Elmer, Cat. No. N066-1296Hot plate, capable of 400CInfrared heater, consisting of an infrared (IR) lamp and mountPipets, volumetric transfer, Class A, 10-
10、mL, Fisher Scientific, Cat. No. 13-651-1KSpectrometer, ICP-AES, Perkin-Elmer, Optima 3000Tongs, beaker, Fisher Scientific, Cat. No. 02-620Watch glass, Teflon, 80-mm diameter, Fisher Scientific, Cat. No. 02-617-1GWater purification system, Barnstead NANOpure II, three module, equipped with Pretreatme
11、nt (D0835),Ultrapure (D0809) and Organic Free (D0820) replacement cartridges, for preparing ASTM D 1193type I reagent grade water, Fisher Scientific, Cat. Nos. 09-050-254, 09-034-104, 09-034-3 and 09-034-175K, respectivelyREAGENTS AND MATERIALSAll reagents shall conform to the specifications establi
12、shed by the Committee on Analytical Reagents ofthe American Chemical Society, when such specifications are available, unless otherwise specified.References to water mean ASTM D 1193 type I reagent grade water.References to catalog numbers and suppliers are included as a convenience to the method use
13、r. Othersuppliers may be used.Copper standard solution, 1000-g/mL, SPEX CertiPrep, Cat. No. PLCU2-2XCopper standard solution, 10-g/mL. Pipette 10 mL of 1000-g/mL copper standard solution into a1000-mL volumetric flask containing approximately 250 mL of water. Using a graduated cylinder,carefully add
14、 20 mL of nitric acid and swirl to mix. Fill to volume with water, cap and mix. Thisstandard has a lifetime of one month.Gloves, Silver Shield laminate (HF resistant), available in small (S), medium (M) and large (L) sizes,Fisher Scientific, Cat. Nos. 11-393-65A, -65B and -65C, respectivelyGloves, Z
15、etex (temperature-resistant), Fisher Scientific, Cat. No. 11-392-50Hydrochloric acid, Ultrex II ultrapure reagent, J. T. Baker, Cat. No. 6900-05Hydrofluoric acid, Ultrex II ultrapure reagent, J. T. Baker, Cat. No. 6904-05Nitric acid, Ultrex II ultrapure reagent, J. T. Baker, Cat. No. 6901-053 of 696
16、2-98PROCEDUREAll labware is to be pre-cleaned by boiling in reagent grade 1:1 nitric acid (mix one part Ultrex IIultrapure reagent grade nitric acid with one part water). Extreme care must be taken to controlcontamination. All acids used are to be Ultrex II ultrapure reagent grade or equivalent.Prep
17、aration of Calibration StandardsPrepare a fresh blank and 1-g/mL copper standard each time the analysis is performed.1. Pipette 10 mL of 10-g/mL copper standard solution into 100-mL volumetric flask. Add none to asecond 100-mL flask to be used as the blank.2. Add 15 mL of hydrochloric acid, 1 mL of
18、nitric acid and 30 mL of water to each flask. Swirl to mixthe contents thoroughly.3. Allow to cool, dilute to the mark, cap and mix well.Sample Preparation1. Using a top loading balance, weigh approximately 100 g (record mass to nearest 0.01 g) of sampleinto a 250-mL Vycor beaker.2. Place the beaker
19、 on a cold hot plate in a fume hood and heat slowly to evaporate contents withoutboiling. An infrared (IR) heater may be used to aid in evaporation.3. Turn the hot plate to high (or about 400C) after the volatile components have evaporated, and allowto heat until smoke evolution ceases.4. Place the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP9621998COPPERINGASOLINEANDNAPHTHABYFLAMEAASORICPAESPDF

链接地址:http://www.mydoc123.com/p-1074589.html