UL 789-2004 UL Standard for Safety Indicator Posts for Fire-Protection Service (Tenth Edition Reprint with Revisions Through and Including May 25 2017)《防火设施用安全指示器标杆的UL标准》.pdf
《UL 789-2004 UL Standard for Safety Indicator Posts for Fire-Protection Service (Tenth Edition Reprint with Revisions Through and Including May 25 2017)《防火设施用安全指示器标杆的UL标准》.pdf》由会员分享,可在线阅读,更多相关《UL 789-2004 UL Standard for Safety Indicator Posts for Fire-Protection Service (Tenth Edition Reprint with Revisions Through and Including May 25 2017)《防火设施用安全指示器标杆的UL标准》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 789 Indicator Posts for Fire-Protection ServiceUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZE
2、D FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Indicator Posts for Fire-Protection Service, UL 789 Tenth Edition, Dated January 9, 2004 SUMMARY OF TOPICS This revision to ANSI/UL 789 is being issued to reect the reaffirmation of the ANSI approval of
3、the Standard. No technical changes have been made to the document. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin and are followed by an effec
4、tive date note indicating the date of publication or the date on which the changed requirement becomes effective. The revised requirements are substantially in accordance with Proposal(s) on this subject dated November 9, 2012. All rights reserved. No part of this publication may be reproduced, stor
5、ed in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warrant
6、ies of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if U
7、L or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, ind
8、emnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this
9、Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are
10、 located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. FEBRUARY 8, 2013 UL 789 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 8, 2013 UL 789 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORI
11、ZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 9, 2004 (Title Page Reprinted: February 8, 2013) 1 UL 789 Standard for Indicator Posts for Fire-Protection Service The First and Second editions were titled Standard for Indicator Posts and numbered UL 262C. First Editio
12、n March, 1931 Second Edition May, 1951 Third Edition June, 1966 Fourth Edition May, 1971 Fifth Edition January, 1975 Sixth Edition July, 1976 Seventh Edition July, 1982 Eighth Edition June, 1987 Ninth Edition September, 1993 Tenth Edition January 9, 2004 This ANSI/UL Standard for Safety consists of
13、the Tenth Edition including revisions through February 8, 2013. The most recent designation of ANSI/UL 789 as a Reaffirmed American National Standard (ANS) occurred on February 8, 2013. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date inf
14、ormation. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a pri
15、nted nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2013 UNDERWRITERS LABORATORIES INC. ANSI/UL 789-2003 (R2013)UL COPYRIGHTED MATE
16、RIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 7, 2008 INDICATOR POSTS FOR FIRE-PROTECTION SERVICE - UL 789 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTROD
17、UCTION 1 Scope .5 2 Components 5 3 Units of Measurement .6 4 Undated References 6 CONSTRUCTION 5 Barrels .6 6 Caps 7 7 Operating Stems 8 7.1 General .8 7.2 Underground types .8 8 Position Indicators 8 8.1 General .8 8.2 Rotating target mechanisms .9 8.3 Vertically moving target mechanisms 10 9 Exten
18、sion Rods 10 10 Handwheels and Wrenches 10 11 Locking and Sealing 10 12 Polymeric Materials and Nonmetallic Parts .11 PERFORMANCE 13 Strength of Parts Test .11 14 Elastomeric Parts (Except Gaskets) Test 12 15 Polymeric Parts Tests .12 15.1 Air oven aging test .12 15.2 Light and water test 13 15.3 10
19、00 cycle operation test 13 MARKING 16 Details .14 AUGUST 7, 2008 INDICATOR POSTS FOR FIRE-PROTECTION SERVICE - UL 789 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 8, 2013 INDICATOR POSTS FOR FIRE-PROTECTION SERVICE - UL 789 4UL
20、COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover indicator posts, including wall and underground types, for use in operating valves of the inside-screw pattern and for indicating the position of
21、the gates in such valves. Indicator posts are primarily intended for use with valves controlling water supplies to sprinkler, deluge, water spray, foam, and standpipe systems used in private re service where connections enter buildings. 1.2 Requirements for the installation and use of the indicator
22、posts covered by this standard are included in the following Standards of the National Fire Protection Association: a) NFPA 11, Low Expansion Foam and Combined Agent Systems; b) NFPA 13, Installation of Sprinkler Systems; c) NFPA 14, Installation of Standpipe and Hose Systems; and d) NFPA 24, Instal
23、lation of Private Fire Service Mains. 2 Components 2.1 Except as indicated in 2.2, a component of a product covered by this standard shall comply with the requirements for that component. 2.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristi
24、c not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.3 A component shall be used in accordance with its rating established for the intended conditions of use. 2.4 Specic components are incomplete in const
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL7892004ULSTANDARDFORSAFETYINDICATORPOSTSFORFIREPROTECTIONSERVICETENTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGMAY252017

链接地址:http://www.mydoc123.com/p-1068926.html