1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 609 Local Burglar Alarm Units and Systems STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL
2、 NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Local Burglar Alarm Units and Systems, UL 609 Twelfth Edition, Dated March 9, 2018 Summary of Topics The twelfth edition of the Standard for Local Burglar Alarm Units and Systems, UL 609, w
3、as issued to expand media to include website. The revised requirements are substantially in accordance with Proposal(s) on this subject dated October 23, 2015. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, e
4、lectronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL
5、 be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibi
6、lity of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, lia
7、bility, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. MARCH 9, 2018 UL 609 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DI
8、STRIBUTION WITHOUT PERMISSION FROM UL MARCH 9, 2018 UL 609 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 9, 2018 1 UL 609 Standard for Local Burglar Alarm Units and Systems Previous unnumbered editions of stan
9、dards covering this material have been published prior to 1928. The standards were titled Local Mercantile Burglar Alarm Systems and Local Burglar Alarm Systems for Bank Vaults and Safes. The rst through fourth editions were titled Local Burglar Alarm System and numbered both UL 609 and UL 610. Firs
10、t Edition April, 1942 Second Edition November, 1947 Third Edition November, 1950 Fourth Edition October, 1959 Fifth Edition May, 1963 Sixth Edition May, 1971 Seventh Edition January, 1972 Eighth Edition March, 1978 Ninth Edition June, 1982 Tenth Edition November, 1990 Eleventh Edition August, 1996 T
11、welfth Edition March 9, 2018 This ANSI/UL Standard for Safety consists of the Twelfth Edition. The most recent designation of ANSI/UL 609 as an American National Standard (ANSI) occurred on March 9, 2018. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, and Title Page
12、. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed no
13、r electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2018 UNDERWRITERS LABORATORIES INC. ANSI/UL 609-2018UL COPYRIGHTED MATERIAL NOT AUTHOR
14、IZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 9, 2018 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .8 2 Co
15、mponents9 3 Units of Measurement .9 4 Undated References 9 5 Terminology 9 6 Glossary 10 7 Installation and Operating Instructions 13 8 Installation and Operating Instructions Physical Media13 9 Electric Shock .14 CONSTRUCTION ASSEMBLY 10 General15 10.1 Product assembly 15 10.2 Electrical protection
16、.15 11 Protection of Service Personnel 18 12 Enclosures .18 12.1 General .18 12.2 Doors and covers 20 12.3 Enclosure openings 21 12.4 Screens and expanded metal 24 12.5 Cast metal.24 12.6 Sheet metal .25 12.7 Product enclosure mounting .27 12.8 Polymeric materials.27 13 Corrosion Protection 28 FIELD
17、 WIRING CONNECTIONS 14 General28 15 Cord Connected Products .28 16 Permanently Connected Products.29 16.1 General .29 16.2 Field-wiring terminals .30 16.3 Field wiring leads.32 16.4 Polarity identication 33 17 Grounding .33 17.1 General .33 17.2 Cord Connected Appliances .34 INTERNAL WIRING 18 Gener
18、al35 19 Wiring Methods.35 20 Separation of Circuits .36 21 Bonding for Grounding 37 MARCH 9, 2018 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL COMPONENTS, ELECTRICAL 22 General41 22.1 Mounti
19、ng of components 41 22.2 Insulating materials 42 22.3 Fuseholders .43 22.4 Current-carrying parts.43 22.5 Power-on indicator .43 23 Overcurrent protection.43 24 Semiconductors 43 25 Switches.43 26 Transformers and Coils44 SPACINGS 27 General44 28 Components .46 PERFORMANCE ALL UNITS 29 General46 29.
20、1 Test units and data .46 29.2 Test samples and miscellaneous data 46 29.3 Test voltages 47 29.4 FCC requirements 47 30 Normal Operation Test 47 31 Current Protection Test 48 32 Input Test48 33 Output Measurement Test .48 34 Electrical Supervision Test .49 35 Undervoltage Operation Test .50 36 Overv
21、oltage Operation Test 50 37 Variable Ambient Test .50 38 Humidity Test 51 39 Leakage Current Tests for Cord-Connected Products .51 40 Electric Shock Current Test 55 41 Overload Test 59 41.1 General .59 41.2 Separately energized circuits 59 42 Endurance Test 60 42.1 General .60 42.2 Separately energi
22、zed circuits 60 43 Jarring Test 60 44 Dielectric Voltage-Withstand Test .61 45 Temperature Test.62 46 Abnormal Operation Test 66 47 Electrical Transient Tests 66 47.1 General .66 47.2 Supply line transients .66 47.3 Internally induced transients .68 47.4 Input/output circuit transients 68 48 AC Indu
23、ction Test.69 49 Polymeric Materials Test.70 MARCH 9, 2018 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 50 Battery Replacement Test .70 51 Drop Test 70 52 Strain Relief Test .71 52.1 Supply
24、Cord .71 52.2 Field-wiring leads.71 53 Ignition Through Bottom-Panel Openings Tests.71 53.1 General .71 53.2 Hot aming oil .71 53.3 Molten pvc and copper72 54 Mechanical Strength Tests for Enclosures .73 55 Special Terminal Assemblies Tests .73 55.1 General .73 55.2 Disconnection and reconnection .7
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL6092018ULSTANDARDFORSAFETYLOCALBURGLARALARMUNITSANDSYSTEMSTWELFTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-1068579.html