《UL 60079-18 (ND)-2015 National Differences For UL 60079-18 Explosive Atmospheres C Part 18 Equipment Protection by Encapsulation m (Fourth Edition Reprint with Revisions Through an_1.pdf》由会员分享,可在线阅读,更多相关《UL 60079-18 (ND)-2015 National Differences For UL 60079-18 Explosive Atmospheres C Part 18 Equipment Protection by Encapsulation m (Fourth Edition Reprint with Revisions Through an_1.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60079-18Standard for Explosive Atmospheres - Part 18: Equipment Protection by Encapsulation mUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUT
2、ION WITHOUT PERMISSION FROM ULNational Differences ForUL 60079-18Standard for Explosive Atmospheres - Part 18: Equipment Protection by Encapsulation mEdition: 4Edition Date: December 14, 2015Adoption of IEC 60079-18, Explosive Atmospheres Part 18: Equipment Protection byEncapsulation “m”, (fourth ed
3、ition issued December 2014) as a new IEC-based UL standard, UL60079-18 (IEC 60079-18:2014) with US National Differences.This document provides a single listing of the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication ma
4、y be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limi
5、ted to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to
6、use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of
7、ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers
8、computer system.Copyright 2015 Underwriters Laboratories Inc.DECEMBER 14, 2015NATIONAL DIFFERENCES FOR UL UL 60079-182UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Diff
9、erences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national difference type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are de
10、viations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requir
11、ements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments
12、 or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national difference entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base
13、 IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure, or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause,table, fi
14、gure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as theaddition, replacement or deletion of certain words or the replacement of an entire clause,subclause, table, figure, or annex of the base IEC text.DECEMBER 14, 20
15、15 NATIONAL DIFFERENCES FOR UL UL 60079-18 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1DV DR Modification of Clause 1 to replace with the following:This part of IEC 60079 standard gives the specific requirements for t
16、he construction,testing and marking of electrical equipment, parts of electrical equipment and Excomponents with the type of protection encapsulation “m” intended for use in explosivegas atmospheres or explosive dust atmospheres.This part standard applies only for encapsulated electrical equipment,
17、encapsulated partsof electrical equipment and encapsulated Ex components (hereinafter always referred to as“m” equipment) where the rated voltage does not exceed 11 kV.The application of electrical equipment in atmospheres, which may contain explosive gasas well as combustible dust simultaneously, m
18、ay require additional protective measures.This standard does not apply to dusts of explosives, which do not require atmosphericoxygen for combustion, or to pyrophoric substances.This standard does not take account of any risk due to an emission of flammable or toxicgas from the dust.This standard su
19、pplements and modifies the general requirements of IEC 60079-0. Wherea requirement of this standard conflicts with a requirement of IEC 60079-0, the requirementof this standard takes precedence.Where references are made to other IEC 60079 standards, the referenced requirementsfound in these standard
20、s shall apply as modified by any applicable U.S. NationalDifferences.2DV DR Modification of Clause 2 references to replace with the following:ASTM-11, Specification for Wire Cloth and Sieves for Testing PurposesIEC 60079-0, Explosive atmospheres Part 0: Equipment General requirementsIEC 60079-7, Exp
21、losive atmospheres Part 7: Equipment protection by increased safety “e”IEC 60079-11, Explosive atmospheres Part 11: Equipment protection by intrinsic safety “i”IEC 60079-15, Explosive atmospheres Part 15: Equipment protection by type of protection nIEC 60079-26, Explosive atmospheres Part 26: Equipm
22、ent with equipment protection level(EPL) GaIEC 60079-31, Explosive atmospheres Part 31: Equipment dust ignition protection byenclosures “t”IEC 60127 (all parts), Miniature fusesDECEMBER 14, 2015NATIONAL DIFFERENCES FOR UL UL 60079-184UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
23、DISTRIBUTION WITHOUT PERMISSION FROM ULIEC 60243-1, Electrical strength of insulating materials Test methods Part 1: Tests at powerfrequenciesIEC 60691, Thermal-links Requirements and application guideIEC 60730-2-9, Automatic electrical controls for household and similar use Part 2-9: Particularrequ
24、irements for temperature sensing controlsIEC 60738-1, Thermistors Directly heated positive temperature coefficient Part 1: GenericspecificationIEC 61140, Protection against electric shock Common aspects for installation and equipmentIEC 61558-1, Safety of power transformers, power supplies, reactors
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL6007918ND2015NATIONALDIFFERENCESFORUL6007918EXPLOSIVEATMOSPHERESCPART18EQUIPMENTPROTECTIONBYENCAPSULATIONMFOURTHEDITIONREPRINTWITHREVISIONSTHROUGHAN_1PDF

链接地址:http://www.mydoc123.com/p-1068357.html