UL 325-2013 UL Standard for Safety Door Drapery Gate Louver and Window Operators and Systems (Sixth Edition Reprint with revisions through and including March 7 2017)《门、窗帘、大门、百页窗和窗.pdf
《UL 325-2013 UL Standard for Safety Door Drapery Gate Louver and Window Operators and Systems (Sixth Edition Reprint with revisions through and including March 7 2017)《门、窗帘、大门、百页窗和窗.pdf》由会员分享,可在线阅读,更多相关《UL 325-2013 UL Standard for Safety Door Drapery Gate Louver and Window Operators and Systems (Sixth Edition Reprint with revisions through and including March 7 2017)《门、窗帘、大门、百页窗和窗.pdf(144页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 325 Door, Drapery, Gate, Louver, and Window Operators and SystemsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATE
2、RIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Door, Drapery, Gate, Louver, and Window Operators and Systems, UL 325 Sixth Edition, Dated October 14, 2013 Summary of Topics The new edition dated October 14, 2013, were issued to inco
3、rporate the following new and revised requirements: Revision to Remove Reference to the Terms Primary and Secondary when Describing Entrapment Protection Devices Addition of Requirements for Detachable Supply Cords Addition of Requirements for Light Sources Other than Incandescent Bulbs Clarication
4、of Permanently Mounted Wireless Devices Reversal Requirements of B1 Protected Gate Operators Residential Garage Door Operator Test Set-Up For Reversal Tests Relocate External Entrapment Protection Requirement of Paragraph 34.1.6 Gate Operators with Wireless External Entrapment Protection Revision of
5、 Pendulum Tolerance Addition of an Exception to Paragraphs 37.3.1 and 37.3.2 Regarding Elastomer Testing Correction of the Force Test Apparatus in Figure 47.2 Revised Tolerances for the Puncture Probe Addition of Requirements for Electronic Instructions Residential Garage Door Operator and System In
6、structions Titles Clarication of the User Manual Clarication of the Instructional and Marking Requirements for Installations Less Than 8 Feet Above the Floor Revision of 58.8.4 to Align with ASTM F2200 The new and revised requirements are substantially in accordance with Proposal(s) on this subject
7、dated November 16, 2012. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. OCTOBER 14, 2013 UL 325 tr1UL COPYRIGHTED M
8、ATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL
9、be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibil
10、ity of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liab
11、ility, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, ta
12、bles, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIRE
13、MENTS notice. The following table lists the future effective dates with the corresponding item. Future Effective Date References December 23, 2014 3.3, 3.15, 32.1.2, 32.1.3, 32.2.2.1, 32.2.2.3, 32.2.2.7, 32.2.2.8, 32.3.1, 32.3.6, 58.3.6, 58.3.7, 59.11 59.13; and Section 47 January 12, 2016 3.4, 3.11
14、, 3.19, 25.11, 31.1.1, 31.1.2, 31.1.6, 31.1.7, 31.1.15, 31.2.1.1, 31.2.1.2, 58.1.6, 58.6.7, 61.5.1, and Table 31.1 OCTOBER 14, 2013 UL 325 tr2UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 14, 2013 1 UL 325 Standard for Door, Draper
15、y, Gate, Louver, and Window Operators and Systems First Edition April, 1973 Second Edition April, 1979 Third Edition April, 1986 Fourth Edition May, 1995 Fifth Edition June, 2002 Sixth Edition October 14, 2013 This ANSI/UL Standard for Safety consists of the Sixth Edition. The most recent designatio
16、n of ANSI/UL 325 as an American National Standard (ANSI) occurred on October 14, 2013. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. The Department of Defense (DoD) has adopted UL 325 on January 21, 1992. The publication o
17、f revised pages or a new edition of this Standard will not invalidate the DoD adoption. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (
18、CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2
19、013 UNDERWRITERS LABORATORIES INC. ANSI/UL 325-2013UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 14, 2013 UL 325 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSI
20、ON FROM UL CONTENTS INTRODUCTION 1 Scope .7 2 Terminology 7 3 Glossary .7 4 Components 10 5 Units of Measurement 11 6 References 11 CONSTRUCTION 7 General .11 8 Frame and Enclosure 11 9 Accessibility of Uninsulated Live Parts and Film-Coated Wire .14 10 Mechanical Assembly .18 11 Protection Against
21、Corrosion .19 12 Power-Supply Connections 21 12.1 General .21 12.2 Cord-connected operators .22 12.3 Drapery operators 22 12.4 Residential garage door operators 23 12.5 Residential and commercial pedestrian door operators 24 12.6 Permanently connected appliances .24 12.7 Exterior shutter and exterio
22、r awning operators .27 13 Live Parts 28 14 Internal Wiring 28 14.1 General .28 14.2 Protection of wiring .29 14.3 Splices and connections 30 14.4 Secondary circuits 30 15 Electrical Insulation .31 16 Motors .32 17 Overload Protection .32 18 Switches and Controls .34 19 Heating Elements .35 20 Lampho
23、lders, Light Emitting Diodes (LED) Light Sources, and Lighting Ballasts 35 21 Receptacles 35 22 Capacitors .36 23 Spacings 36 24 Grounding .38 PROTECTION AGAINST RISK OF INJURY TO PERSONS 25 General 39 26 Pressure Vessels and Parts Subject to Pressures 44 26.1 General .44 26.2 Pressure-relief device
24、s 45 27 Moving Parts .46 28 Surface Temperatures .47 29 Pedestrian Doors and Door Operators .48 OCTOBER 14, 2013 UL 325 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 29.1 General .48 29.2 Panic hardware 48 29.3 Interruption of power 48 29
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL3252013ULSTANDARDFORSAFETYDOORDRAPERYGATELOUVERANDWINDOWOPERATORSANDSYSTEMSSIXTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGMARCH72017

链接地址:http://www.mydoc123.com/p-1068068.html