UL 325 CRD-2018 UL Standard for Safety Door Drapery Gate Louver and Window Operators and Systems - Section Paragraph Reference 13 4 1 Subject UL 325 Residential Garage Door Operat.pdf
《UL 325 CRD-2018 UL Standard for Safety Door Drapery Gate Louver and Window Operators and Systems - Section Paragraph Reference 13 4 1 Subject UL 325 Residential Garage Door Operat.pdf》由会员分享,可在线阅读,更多相关《UL 325 CRD-2018 UL Standard for Safety Door Drapery Gate Louver and Window Operators and Systems - Section Paragraph Reference 13 4 1 Subject UL 325 Residential Garage Door Operat.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): FDDRStandard Number: UL 325Standard Title: Standard for Door, Drapery, Gate, Louver, and Window Operatorsand SystemsEdition Date: May 19, 2018Edition Number: 7Section / Paragraph Reference: 13.4.1Subj
3、ect: UL 325 Residential Garage Door Operator with power supply cordSupercedes prior Certification Requirement Decision issued 2017-04-19 for 6thedition UL 325DECISION:132.4.1 With reference to 132.1.1, a residential garage door operator supplied with a flexible cord forconnection to a supply circuit
4、 shall:a) Not be rated greater than 120 V;b) Not have a maximum appliance current draw through the supply cord greater than 15 Aunder a locked-rotor condition including the current draw of lamps and external devices;c) Be constructed of an 18 AWG minimum flexible cord of Type SJT or heavier duty;d)
5、Not be longer than 6 ft (1.83 m); ande) Incorporate a grounding conductor and be terminated with a grounding type attachment plug.Exception (for item e): A residential garage door operator that does not have exposed dead metal parts,nor dead metal parts within its enclosure that are exposed to conta
6、ct by the user or serviceman, and thatare likely to become energized, is not required to be provided with a grounding means; see 25.1. Whengrounding is not provided, a power supply cord with grounding conductor and grounding type attachmentplug shall not be used.RATIONALE FOR DECISION:For many cord-
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL325CRD2018ULSTANDARDFORSAFETYDOORDRAPERYGATELOUVERANDWINDOWOPERATORSANDSYSTEMSSECTIONPARAGRAPHREFERENCE1341SUBJECTUL325RESIDENTIALGARAGEDOOROPERATPDF

链接地址:http://www.mydoc123.com/p-1068067.html