UL 1363 CRD-2016 UL Standard for Safety Relocatable Power Taps - Section Paragraph Reference Sections 1 (Scope) 3 (Glossary) Sections 11 1 7 12 (Construction) and 34 (Performance).pdf
《UL 1363 CRD-2016 UL Standard for Safety Relocatable Power Taps - Section Paragraph Reference Sections 1 (Scope) 3 (Glossary) Sections 11 1 7 12 (Construction) and 34 (Performance).pdf》由会员分享,可在线阅读,更多相关《UL 1363 CRD-2016 UL Standard for Safety Relocatable Power Taps - Section Paragraph Reference Sections 1 (Scope) 3 (Glossary) Sections 11 1 7 12 (Construction) and 34 (Performance).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): XBYSStandard Number: UL 1363Standard Title: Standard for Relocatable Power TapsEdition Date: October 6, 2014Edition Number: 4Section / Paragraph Reference: S
3、ections 1 (Scope); 3 (Glossary); Sections 11.1.7, 12(Construction) and 34 (Performance)Subject: Class 2 LeadDECISION:1 Scope1.1 These requirements cover indoor use cord and plug connected relocatable power taps (RPT) rated250 V AC or less and 20 Amperes or less. A RPT may include an integral Class 2
4、 power supply with anintegral lead and/or connector(s) output. RPT are for use as a movable power supply connection for cordand plug connected electrical utilization equipment in accordance with the National Electric Code, NFPA70.3 Glossary3.2.1 CLASS 2 LEAD - Consists of a factory-made, power-limit
5、ed cable with a connector at one end. Theother end is secured within the housing or enclosure of the RPT. The connector is intended for connectionto the Class 2 separable interface.3.2.2 CLASS 2 SEPARABLE INTERFACE A separable component containing Class 2 low-voltageconnector(s) only (such as Univer
6、sal Serial Bus (USB) connector(s).3.11 RELOCATABLE POWER TAP (RPT) -p) Provided with an integral Class 2 lead and mating Class 2 separable interface, or an integralpower supply with one or more Class 2 output connector(s).11.1.7 Class 2 Lead11.1.8 A Class 2 lead may be one of the following types:a)
7、Type CL2 cable in accordance with the Standard for Power-Limited Circuit Cables, UL 13b) An appliance wiring material with a maximum length of 10 feet (3.5 m), minimum of 26 AWG,rated minimum VW-1 flammability and minimum 300 V, in accordance with the Standard forAppliance Wiring Material, UL 758.11
8、.1.9 One end of a Class 2 lead shall be either molded-on or permanently attached to the RPT housingor enclosure.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL11.1.10 The other end of a Class 2 lead shall terminate in a connector capable of b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1363CRD2016ULSTANDARDFORSAFETYRELOCATABLEPOWERTAPSSECTIONPARAGRAPHREFERENCESECTIONS1SCOPE3GLOSSARYSECTIONS111712CONSTRUCTIONAND34PERFORMANCEPDF

链接地址:http://www.mydoc123.com/p-1067446.html