REG UFGS-06 71 33-2012 FIBERGLASS REINFORCED PLASTIC (FRP) LADDERS.pdf
《REG UFGS-06 71 33-2012 FIBERGLASS REINFORCED PLASTIC (FRP) LADDERS.pdf》由会员分享,可在线阅读,更多相关《REG UFGS-06 71 33-2012 FIBERGLASS REINFORCED PLASTIC (FRP) LADDERS.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-06 71 33 (May 2012)-Preparing Activity: NASA SupersedingUFGS-06 71 33 (February 2011)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in Agreement with UMRL dated April 2012*SECTION TABLE OF CONTENTSDIVISION 06 - WOOD, PLASTICS, AND COMPOSITESSECTION 06 71 3
2、3FIBERGLASS REINFORCED PLASTIC (FRP) LADDERS05/12PART 1 GENERAL1.1 SUMMARY1.2 REFERENCES1.3 ADMINISTRATIVE REQUIREMENTS1.3.1 Pre-Installation Meetings1.4 SUBMITTALS1.5 QUALITY ASSURANCE1.5.1 Qualification of Manufacturer1.5.2 Qualification of Engineer of Record1.6 PRODUCT DELIVERY AND STORAGEPART 2
3、PRODUCTS2.1 SYSTEM DESCRIPTION2.1.1 Design Requirements2.1.2 Performance Requirements2.1.2.1 Structural Performance of Ladders2.1.2.2 Thermal Movements2.1.2.3 Safety Performance of Ladders2.2 LADDERS2.3 LADDER SAFETY CAGESPART 3 EXECUTION3.1 GENERAL3.2 FABRICATION3.3 FASTENING TO CONSTRUCTION-IN-PLA
4、CE3.4 PERFORMANCE REQUIREMENTS3.5 INSTALLATION3.6 MANUFACTURERS WARRANTY- End of Section Table of Contents -SECTION 06 71 33 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-06 71 33 (May 2012)-Preparing Acti
5、vity: NASA SupersedingUFGS-06 71 33 (February 2011)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in Agreement with UMRL dated April 2012*SECTION 06 71 33FIBERGLASS REINFORCED PLASTIC (FRP) LADDERS05/12*NOTE: This guide specification covers fiberglass reinforced plastic (FRP)ladders, customar
6、ily manufactured to meet specific requirements in building construction and fabricated FRP items not a part of the structural FRP components or framework.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new proje
7、ct specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not b
8、rackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*Include in drawings a complete design indicating the character of the work to be performed and giving the following:Lo
9、cation and details of each fabricated FRP ladder component showing all dimensions, shapes, and sizes of members, connections, and the relation of items to other building components.Anchorage devices embedded in other construction, including but not limited to, precast concrete wall panels, precast c
10、oncrete structural members, precast concrete roof decking, brick and block masonry, and precast stone work.SECTION 06 71 33 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Anchorage devices to structural steel framework, including, but not limi
11、ted to, steel bar grating, steel floor plates, and structural steel roof or floor decking.*1.1 SUMMARYThis Section includes, but is not limited to, new fiberglass reinforced plastic (FRP) ladder systems including safety ladder cages, mounting systems and related accessories.1.2 REFERENCES*NOTE: This
12、 paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a
13、 RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification
14、when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.AMERICAN LADDER INSTITUTE (ALI/LADDER)ALI/LADDER A14.3 (2008)
15、 Standard for Fixed Ladders and Safety RequirementsAMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)ASCE 7-10 (2010; Change 2010; Change 2011; Errata 2011; Change 2011) Minimum Design Loads for Buildings and Other StructuresASTM INTERNATIONAL (ASTM)ASTM D1148 (2007a) Standard Test Method for Rubber Deterio
16、rationDiscoloration from Ultraviolet (UV) and Heat Exposure of Light-Colored SurfacesASTM D2344/D2344M (2000; R 2006) Standard Test Method for SECTION 06 71 33 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Short-Beam Strength of Polymer Matri
17、x Composite Materials and Their LaminatesASTM D4000 (2011) Standard Classification System for Specifying Plastic MaterialsASTM D430 (2006e1) Standard Test Methods for Rubber Deterioration - Dynamic FatigueASTM D495 (1999; R 2004) Standard Test Method for High-Voltage, Low-Current, Dry Arc Resistance
18、 of Solid Electrical InsulationASTM D638 (2010) Standard Test Method for Tensile Properties of PlasticsASTM D696 (2008) Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between -30 degrees C and 30 degrees C With a Vitreous Silica DilatometerASTM D790 (2010) Flexural Prop
19、erties of Unreinforced and Reinforced Plastics and Electrical Insulating MaterialsASTM E84 (2012) Standard Test Method for Surface Burning Characteristics of Building MaterialsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 101 (2012; Amendment 1 2012) Life Safety CodeU.S. NATIONAL ARCHIVES AND RECO
20、RDS ADMINISTRATION (NARA)29 CFR 1910.27 Fixed Ladders29 CFR 1926 Safety and Health Regulations for Construction1.3 ADMINISTRATIVE REQUIREMENTS1.3.1 Pre-Installation MeetingsWithin 30 _ calendar days of Contract Award, a pre-installation meeting will be scheduled by the Contracting Officer. Submit th
21、e following for review:a. Qualification of Manufacturerb. Qualification of Engineer of Recordc. Manufacturers Catalog DataInclude two copies of manufacturers specifications, load tables, dimension diagrams, and anchor details for the following items:1. FRP Ladders and Ladder Safety CagesSECTION 06 7
22、1 33 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2. Anchorage Materialsd. Fabrication and Installation Drawings and DetailsInclude plans, elevations, sections, and details of FRP fabrications and their connections. Show anchorage and all ac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGUFGS0671332012FIBERGLASSREINFORCEDPLASTICFRPLADDERSPDF

链接地址:http://www.mydoc123.com/p-1019631.html